The formation of the retroreflected light field is introduced in the paper and the components of the retroreflected light field are analyzed.Furthermore,a deep analysis of the factors affecting energy distribution of ...The formation of the retroreflected light field is introduced in the paper and the components of the retroreflected light field are analyzed.Furthermore,a deep analysis of the factors affecting energy distribution of the retroreflected light,such as design deviation,angle of incidence,was made.The simulation of the retroreflected light field was done.Recommendation is made in detail on both the energy distribution of the retroreflected light field at different working distances and the energy distribution of the retroreflected light field at a short distance when the diverging light comes.At last,two kinds of measuring instrument for the retroreflector are introduced,one is the long tunnel measuring instrument,the other is the minitype measuring instrument based on the character of the retroreflector when the diverging light comes.展开更多
When interference microscope measures the surface rough of the micromechanical device, as soon as the work distance of interference microscope and the depth of field is shortened, the interference images become slur f...When interference microscope measures the surface rough of the micromechanical device, as soon as the work distance of interference microscope and the depth of field is shortened, the interference images become slur for the measured object if there has small interference after clear focus. The auto-focusing system is introduced into the interference microscope, the system can obtain high definition interference image rapidly,and can improve the measuring velocity and measuring precision. The system is characterized by auto-focusing range of ±150 μm, auto-focusing precision of ±0.3 μm, auto-focusing time of 4~8 s.展开更多
A new displacement measurement system is described in this paper according to the basic principles of traditional lasertriangulation method. The range of the traditional measuring method is enlarged by measuring in se...A new displacement measurement system is described in this paper according to the basic principles of traditional lasertriangulation method. The range of the traditional measuring method is enlarged by measuring in sections. Three independent CCDs, which are distributed uniformly along the optical axis, are used to achieve subsection measurement. The planemirror is regarded as a virtual detector. When imaging beam is reflected by the plane mirror, the beam is imaged on theCC D. The designed system is equivalent to add a CCD. The feasibility of the displacement measurement system is verifiedby the experiment.展开更多
In the standard model of particle physics, photons are massless particles with a particular dispersion relation. Tests of this claim at different scales are both interesting and important. Experiments in territory lab...In the standard model of particle physics, photons are massless particles with a particular dispersion relation. Tests of this claim at different scales are both interesting and important. Experiments in territory labs and several exterritorial tests have put some upper limits on photon mass, e.g., torsion balance experiment in the lab shows that photon mass should be smaller than 1.2 x 10-51g. In this work, this claim is tested at a cosmological scale by looking at strong gravitational lensing data available and an upper limit of 8.71 x 10-39g on photon mass is given. Observations of energy-dependent gravitational lensing with not yet available higher accuracy astrometry instruments may constrain photon mass better.展开更多
文摘The formation of the retroreflected light field is introduced in the paper and the components of the retroreflected light field are analyzed.Furthermore,a deep analysis of the factors affecting energy distribution of the retroreflected light,such as design deviation,angle of incidence,was made.The simulation of the retroreflected light field was done.Recommendation is made in detail on both the energy distribution of the retroreflected light field at different working distances and the energy distribution of the retroreflected light field at a short distance when the diverging light comes.At last,two kinds of measuring instrument for the retroreflector are introduced,one is the long tunnel measuring instrument,the other is the minitype measuring instrument based on the character of the retroreflector when the diverging light comes.
文摘When interference microscope measures the surface rough of the micromechanical device, as soon as the work distance of interference microscope and the depth of field is shortened, the interference images become slur for the measured object if there has small interference after clear focus. The auto-focusing system is introduced into the interference microscope, the system can obtain high definition interference image rapidly,and can improve the measuring velocity and measuring precision. The system is characterized by auto-focusing range of ±150 μm, auto-focusing precision of ±0.3 μm, auto-focusing time of 4~8 s.
基金supported by the Science and Technology Plan of Hebei Province, China (No. 10212149)
文摘A new displacement measurement system is described in this paper according to the basic principles of traditional lasertriangulation method. The range of the traditional measuring method is enlarged by measuring in sections. Three independent CCDs, which are distributed uniformly along the optical axis, are used to achieve subsection measurement. The planemirror is regarded as a virtual detector. When imaging beam is reflected by the plane mirror, the beam is imaged on theCC D. The designed system is equivalent to add a CCD. The feasibility of the displacement measurement system is verifiedby the experiment.
文摘In the standard model of particle physics, photons are massless particles with a particular dispersion relation. Tests of this claim at different scales are both interesting and important. Experiments in territory labs and several exterritorial tests have put some upper limits on photon mass, e.g., torsion balance experiment in the lab shows that photon mass should be smaller than 1.2 x 10-51g. In this work, this claim is tested at a cosmological scale by looking at strong gravitational lensing data available and an upper limit of 8.71 x 10-39g on photon mass is given. Observations of energy-dependent gravitational lensing with not yet available higher accuracy astrometry instruments may constrain photon mass better.