The effect of Ce addition on the morphology of the α(Al)-Al2Cu eutectic in Al-Si-Cu alloy was investigated using thermal analysis, light microscopy, scanning electron microscopy, focused ion beam and energy dispers...The effect of Ce addition on the morphology of the α(Al)-Al2Cu eutectic in Al-Si-Cu alloy was investigated using thermal analysis, light microscopy, scanning electron microscopy, focused ion beam and energy dispersive analysis. The results show that the eutectic α(Al)-Al2Cu forms within small space between dendrites, silicon and AlSiFeMn plates. Eutectic Al2Cu is not lamellar but degenerated. However, Al2Cu in Ce-modified alloys is more compact. Ce partially dissolves in Al2Cu, which is a viable reason for the formation of coarser Al2Cu. The addition of Ce also increases the microhardness of theα(Al)-Al2Cu eutectic by almost 10%compared with the basic Al-Si-Cu alloy.展开更多
annular beam tri-heterodyne confocal microscope has been proposed to improve the anti-environmental interference capability and the resolution of a eonfoeal microscope. It simultaneously detects far-, on-, and near-fo...annular beam tri-heterodyne confocal microscope has been proposed to improve the anti-environmental interference capability and the resolution of a eonfoeal microscope. It simultaneously detects far-, on-, and near-focus signals with given phase differences by dividing the measured light path of the eonfoeal microscope into three sub-paths (signals). Pair-wise real-time heterodyne subtraction of the three signals is used to improve the anti-environmental interference capability, axial resolution, and linearity; and a shaped annular beam super-resolution technique is used to improve lateral resolution. Theoretical analyses and preliminary experiments indicate that an axial resolution of about 1 nm can be achieved with a shaped annular beam tri-heterodyne confoeal microscope and its lateral resolution can be better than 0.2 um for A = 632.8 nm, the numerical aperture of the lens of the microscope is NA = 0.85, and the normalized radius e = 0.5.展开更多
A single-axis normal-tracking measurement system is proposed, which can solve the problem of measuring large curved surface. According to Collins formula, the tilt dependent error of the measurement system is studied,...A single-axis normal-tracking measurement system is proposed, which can solve the problem of measuring large curved surface. According to Collins formula, the tilt dependent error of the measurement system is studied, which uses Gaussian beam as the light source. By theoretical analysis and numerical simulation, the influence of the error is presented. The results show that there is the difference between point source and Gaussian beam for differential confocal microscopy. The opti-mal diameter of pinhole can be determined by the mathematical model and the actual parameters of the measurement system. The optimal pinhole diameter of this measurement system is 20 to 35 pm for 633 nm wavelength light source.展开更多
High-speed vehicle dynamic envelope curve is defined as the maximum limit outline affected by a variety of adverse factors while the train is running. Considering the difficulties in the current measurement system suc...High-speed vehicle dynamic envelope curve is defined as the maximum limit outline affected by a variety of adverse factors while the train is running. Considering the difficulties in the current measurement system such as complicated calibration process,cumbersome aided-instruments,strict limitation of working distance, this paper carries out an optical method in which two high-speed cameras with variable-zoom lenses are adopted as binocular stereo sensors of measurement system and a high-ac-curacy 3D target with fast reconstruction is designed. The intrinsic parameters of the sensors and the relative positions between coordinate systems are solved by the method of colinearity constrained optimization algorithm. The calibration process is easy to operate and the device is also of portability. Most importantly, the severe working distance limitation between sensors and measured body is solved, enhancing the adaptability of measurement system to environment. Experimental results show that when the sensors are in the range of 8 -16 m away from the measured body, system accuracy can reach up to ±0. 5 mm, which meets the requirements to measure the dynamic envelope curve of high-speed vehicle.展开更多
文摘The effect of Ce addition on the morphology of the α(Al)-Al2Cu eutectic in Al-Si-Cu alloy was investigated using thermal analysis, light microscopy, scanning electron microscopy, focused ion beam and energy dispersive analysis. The results show that the eutectic α(Al)-Al2Cu forms within small space between dendrites, silicon and AlSiFeMn plates. Eutectic Al2Cu is not lamellar but degenerated. However, Al2Cu in Ce-modified alloys is more compact. Ce partially dissolves in Al2Cu, which is a viable reason for the formation of coarser Al2Cu. The addition of Ce also increases the microhardness of theα(Al)-Al2Cu eutectic by almost 10%compared with the basic Al-Si-Cu alloy.
基金Project supported by the National Natural Science Foundation of China (Grant No 50475035), the Doctoral Program of Higher Education of China (Grant No 20050213035) and the Program for New Century Excellent Talents in University of China (Grant No NCET-05-0348).
文摘annular beam tri-heterodyne confocal microscope has been proposed to improve the anti-environmental interference capability and the resolution of a eonfoeal microscope. It simultaneously detects far-, on-, and near-focus signals with given phase differences by dividing the measured light path of the eonfoeal microscope into three sub-paths (signals). Pair-wise real-time heterodyne subtraction of the three signals is used to improve the anti-environmental interference capability, axial resolution, and linearity; and a shaped annular beam super-resolution technique is used to improve lateral resolution. Theoretical analyses and preliminary experiments indicate that an axial resolution of about 1 nm can be achieved with a shaped annular beam tri-heterodyne confoeal microscope and its lateral resolution can be better than 0.2 um for A = 632.8 nm, the numerical aperture of the lens of the microscope is NA = 0.85, and the normalized radius e = 0.5.
基金Quantity Dissemination and Quality Safety Project of AQSIQ(No.ALC1501)National Key Scientific Instrument and Equipment Development Projects,China(No.2013YQ170539)
文摘A single-axis normal-tracking measurement system is proposed, which can solve the problem of measuring large curved surface. According to Collins formula, the tilt dependent error of the measurement system is studied, which uses Gaussian beam as the light source. By theoretical analysis and numerical simulation, the influence of the error is presented. The results show that there is the difference between point source and Gaussian beam for differential confocal microscopy. The opti-mal diameter of pinhole can be determined by the mathematical model and the actual parameters of the measurement system. The optimal pinhole diameter of this measurement system is 20 to 35 pm for 633 nm wavelength light source.
基金National Science and Technology Major Project(No.2016ZX04003001)
文摘High-speed vehicle dynamic envelope curve is defined as the maximum limit outline affected by a variety of adverse factors while the train is running. Considering the difficulties in the current measurement system such as complicated calibration process,cumbersome aided-instruments,strict limitation of working distance, this paper carries out an optical method in which two high-speed cameras with variable-zoom lenses are adopted as binocular stereo sensors of measurement system and a high-ac-curacy 3D target with fast reconstruction is designed. The intrinsic parameters of the sensors and the relative positions between coordinate systems are solved by the method of colinearity constrained optimization algorithm. The calibration process is easy to operate and the device is also of portability. Most importantly, the severe working distance limitation between sensors and measured body is solved, enhancing the adaptability of measurement system to environment. Experimental results show that when the sensors are in the range of 8 -16 m away from the measured body, system accuracy can reach up to ±0. 5 mm, which meets the requirements to measure the dynamic envelope curve of high-speed vehicle.