Prestack reverse time migration(PSTM) is a common imaging method; however low-frequency noises reduce the structural imaging precision. Thus, the suppression of migration noises must be considered. The generation me...Prestack reverse time migration(PSTM) is a common imaging method; however low-frequency noises reduce the structural imaging precision. Thus, the suppression of migration noises must be considered. The generation mechanism of low-frequency noises is analyzed and the up-, down-, left-, and right-going waves are separated using the Poynting vector of the acoustic wave equation. The computational complexity and memory capacitance of the proposed method are far smaller than that required when using the conventional separation algorithm of 2D Fourier transform. The normalized wavefield separation crosscorrelation imaging condition is used to suppress low-frequency noises in reverse time migration and improve the imaging precision. Numerical experiments using the Marmousi model are performed and the results show that the up-, down-, left-, and right-going waves are well separated in the continuation of the wavefield using the Poynting vector. We compared the imaging results with the conventional method, Laplacian filtering, and wavefield separation with the 2D Fourier transform. The comparison shows that the migration noises are well suppressed using the normalized wavefield separation cross-correlation imaging condition and higher precision imaging results are obtained.展开更多
A noise model for the analog correlator used in the ultra wideband receivers is proposed due to lack of simulation capability on noise performance of the correlator in current EDA tools.The analog correlator circuit i...A noise model for the analog correlator used in the ultra wideband receivers is proposed due to lack of simulation capability on noise performance of the correlator in current EDA tools.The analog correlator circuit is divided into several parts to calculate the equivalent noise sources respectively.The ideal impulse generators,instead of the noise sources,are then applied to obtain the time varying transfer functions.Fourier transforms are carried out to explore the relationship between the noise input and output in frequency domain for each part.Then the symmetrical noise sources are grouped together and the periodicity of the circuit is utilized to further simplify the model.This model can be used to evaluate noise performance of the correlator.展开更多
Two gain forms of spectral amplitude subtraction are derived theoretically without neglecting the correlation of speech and noise spectrum during the period of a fralne. In the implementation, the constrained gain is ...Two gain forms of spectral amplitude subtraction are derived theoretically without neglecting the correlation of speech and noise spectrum during the period of a fralne. In the implementation, the constrained gain is expressed as a function of noncausal a priori SNR (Signal-to-Noise Ratio). Noise and noncausal a priori SNR are estimated from the multitaper spectrum of the noisy signal with algorithms modified to be suitable for the multitaper spectruln. Objective evaluations show that in case of white Gaussian noise the proposed method outperforms some methods based on LSA (Log Spectral Amplitude) in terms of MBSD (Modified Bark Spectral Distortion), segmental SNR and overall SNR, and informal listening tests show that speech reconstructed in this way has little speech distortion and musical noise is nearly inaudible even at low SNR.展开更多
When Kalman filter is used in the estimation of Vasicek term structure of interest rates,it is usual to assume that the measurement noise is uncorrelated.Study results are more favorable to the assumption of correlate...When Kalman filter is used in the estimation of Vasicek term structure of interest rates,it is usual to assume that the measurement noise is uncorrelated.Study results are more favorable to the assumption of correlated measurement noise.An augmented state Kalman filter form for Vasicek model is proposed to optimally estimate the unobservable state variable with the assumption of correlated measurement noise.Empirical results indicate that the model with sequentially correlated measurement noise can more accurately describe the dynamics of the term structure of interest rates.展开更多
A positioning volume ellipsoid method is proposed to represent tumor volume in the workspace of a high-intensity-focused ultrasound (HIFU) surgery platform during the platform's positioning motion. To this simplif...A positioning volume ellipsoid method is proposed to represent tumor volume in the workspace of a high-intensity-focused ultrasound (HIFU) surgery platform during the platform's positioning motion. To this simplified tumor model, a nearest neighbor search method is used to determine intermediate configuration and goal configuration, which the treatment head and ultrasound focus must pass in their localization to target volume. Based on the decided configurations, the continuity condition of combined Bezier curve in Euclidean space and De Casteljau algorithm on Lie group SO(3) are integrated to construct a combined Bezier positioning path of C2 continuity at junctional configuration, and an illustration of different positioning path planning is analyzed based on a liver tumor case.展开更多
In this paper, the vibration arid sound radiation of the underwater complexshell-structure which is the cylindrical shell with hemi-spherical shell on the ends are studied bystatistical energy analysis (SEA). The whol...In this paper, the vibration arid sound radiation of the underwater complexshell-structure which is the cylindrical shell with hemi-spherical shell on the ends are studied bystatistical energy analysis (SEA). The whole shell-structure is divided into the four subsystems,and the SEA physical model and power flow balance equations among these subsystems are established.The similitude relations of input power, coupling loss factor and modal density of the subsystemsbetween the complex shell-structure and its scaled-down model are analyzed. According to thesimilitude theory and power flow balance equations, when the immerged shell-structures are excited,the similar relations of spatially averaged vibration response and underwater radiating sound powerare established for the complex shell-structure and its scaled-down model.展开更多
We study the steady state properties ofa genotype selection model in presence of correlated Gaussian whitenoise. The effect of the noise on the genotype selection model is discussed. It is found that correlated noise ...We study the steady state properties ofa genotype selection model in presence of correlated Gaussian whitenoise. The effect of the noise on the genotype selection model is discussed. It is found that correlated noise can breakthe balance of gene selection and induce the phase transition which can makes us select one type gene haploid from agene group.展开更多
Objective To evaluate the efficacy of minimally invasive perventricular device closure of ventricular septal defect(VSD). Methods Between September 2011 and February 2013, we collected 40 patients who underwent perven...Objective To evaluate the efficacy of minimally invasive perventricular device closure of ventricular septal defect(VSD). Methods Between September 2011 and February 2013, we collected 40 patients who underwent perventricular closure via a small lower sternal incision(minimally invasive group), aged 15.5±3.5 years(12 months to 32 years) with a body weight of 24.2±7.5 kg(10.8-58.0 kg). The mean size of VSD was 5.6±0.5 mm(2-14 mm). Another 40 patients were included as the surgical group, receiving the conventional surgical repair of VSD. The device of the minimally invasive group was released under the guidance of transesophageal echocardiography. Success rate, cardiac indicators, and clinical outcomes of the 2 groups were compared. Results The patients in the surgical group and those in the minimally invasive group showed similar results in success rate(both 97.5%). The procedure time, intensive care unit stay, hospital stay, and postoperative recovery time in the minimally invasive group were significantly shorter than those in the surgical group(58±21 minutes versus 145±26 minutes, 2±1 days versus 8±3 days, 5±1 days versus 16±6 days, 3±1 days versus 90±20 days, all P<0.05). The minimally invasive group had a higher incidence of conduction anomalies(17.5% versus 2.5%, P<0.05). In the follow-up period of 3-12 months, there was no new residual shunt, noticeable aortic regurgitation, significant arrhythmias, or device failure except for new complications in the surgical group. Conclusions The success rate of minimally invasive perventricular device closure of VSD under transesophageal echocardiography guidance is similar to that of conventional surgical repair, but the short-term outcomes of the minimally invasive approach is much better. Long-term follow-up is necessary to confirm the effectiveness of this technique.展开更多
A T equivalent high frequency heterojunction bipolar transistor (HBT) noise model is reported.This model is derived from Hawkins noise model commonly used in Si BJT.The main modifications include the influence of th...A T equivalent high frequency heterojunction bipolar transistor (HBT) noise model is reported.This model is derived from Hawkins noise model commonly used in Si BJT.The main modifications include the influence of the ideality factor,emitter resistance,intrinsic base collector capacitance,extrinsic base collector capacitance and other parasitic elements of HBT represented in equivalent circuit topology.In order to calculate accurate noise parameters from the equivalent circuit,the noise correlation matrix method is used to avoid any simplifications generated in circuit transformations and complex noise measurements.The analysis of the influence of the equivalent circuit elements on the minimum noise figure is reported,the results of analysis agree well with the physics explanations.By means of the formulae derived from device physics of HBT,the influence of device parameters on the minimum noise figure is also represented.展开更多
The degradation process of organosol coated tinplate in beverage was investigated by electrochemical noise (EN) technique combined with morphology characterization.EN data were analyzed using phase space reconstructio...The degradation process of organosol coated tinplate in beverage was investigated by electrochemical noise (EN) technique combined with morphology characterization.EN data were analyzed using phase space reconstruction theory.With the correlation dimensions obtained from the phase space reconstruction,the chaotic behavior of EN was quantitatively evaluated.The results show that both electrochemical potential noise (EPN) and electrochemical current noise (ECN) have chaotic properties.The correlation dimensions of EPN increase with corrosion extent,while those of ECN seem nearly unchanged.The increased correlation dimensions of EPN during the degradation process are associated with the increased susceptibility to local corrosion.展开更多
Aiming at the effective realization of particle filter for maneuvering target tracking in multi-sensor measurements,a novel multi-sensor multiple model particle filtering algorithm with correlated noises is proposed.C...Aiming at the effective realization of particle filter for maneuvering target tracking in multi-sensor measurements,a novel multi-sensor multiple model particle filtering algorithm with correlated noises is proposed.Combined with the kinetic evolution equation of target state,a multi-sensor multiple model particle filter is firstly constructed,which is also used as the basic framework of a new algorithm.In the new algorithm,in order to weaken the adverse influence from random measurement noises in the measuring process of particle weight,a weight optimization strategy is introduced to improve the reliability and stability of particle weight.In addition,considering the correlated noise existing in the practical engineering,a decoupling method of correlated noise is given by the rearrangement and transformation of the state transition equation and measurement equation.Since the weight optimization strategy and noise decoupling method adopt respectively the center fusion structure and the off-line way,it improves the adverse effect effectively on computational complexity for increasing state dimension and sensor number.Finally,the theoretical analysis and experimental results show the feasibility and efficiency of the proposed algorithm.展开更多
Molecular dynamics calculation of UO2 in a wide temperature range are presented and dis- cussed. The calculated lattice parameters, mean square displacements, and dynamic prop- erty of phonon-level density of the velo...Molecular dynamics calculation of UO2 in a wide temperature range are presented and dis- cussed. The calculated lattice parameters, mean square displacements, and dynamic prop- erty of phonon-level density of the velocity auto-correlation functions for UO2 are provided. The Morelon potential and the Basak potential are employed. It confirms that the cal- culated lattice parameters using the Basak potential are in nearly perfect agreement with the reported values. The models successfully predict mean square displacement and Bredig transition. Furthermore, the phonon-level density of uranium dioxide are discussed. The intensity of phonon-level density increases with temperature, and the properties of UO2 are characterized by large thermal vibrations rather than extensive disorder.展开更多
Background: Until recently it has not been possible to isolate the mechanical behavior of individual muscles during passive stretching. Muscle shear modulus(an index of muscle stiffness) measured using ultrasound shea...Background: Until recently it has not been possible to isolate the mechanical behavior of individual muscles during passive stretching. Muscle shear modulus(an index of muscle stiffness) measured using ultrasound shear wave elastography can be used to estimate changes in stiffness of an individual muscle. The aims of the present study were(1) to determine the shear modulus—knee angle relationship and the slack angle of the vastus medialis oblique(VMO), rectus femoris(RF), and vastus lateralis(VL) muscles;(2) to determine whether this differs between the muscles.Methods: Nine male rowers took part in the study. The shear modulus of VMO, RF, and VL muscles was measured while the quadriceps was passively stretched at 3°/s. The relationship between the muscle shear modulus and knee angle was plotted as shear modulus—knee angle curve through which the slack angle of each muscle was determined.Results: The shear modulus of RF was higher than that of VMO and VL when the muscles were stretched over 54°(all p < 0.01). No significant difference was found between the VMO and VL(all p > 0.05). The slack angle was similar among the muscles: 41.3°± 10.6°, 44.3°± 9.1°, and 44.3°± 5.6° of knee flexion for VMO, RF, and VL, respectively(p = 0.626).Conclusion: This is the first study to experimentally determine the muscle mechanical behavior of individual heads of the quadriceps during passive stretching. Different pattern of passive tension was observed between mono-and bi-articular muscles. Further research is needed to determine whether changes in muscle stiffness are muscle-specific in pathological conditions or after interventions such as stretching protocols.展开更多
New sigma point filtering algorithms, including the unscented Kalman filter (UKF) and the divided difference filter (DDF), are designed to solve the nonlinear filtering problem under the condition of correlated no...New sigma point filtering algorithms, including the unscented Kalman filter (UKF) and the divided difference filter (DDF), are designed to solve the nonlinear filtering problem under the condition of correlated noises. Based on the minimum mean square error estimation theory, the nonlinear optimal predictive and correction recursive formulas under the hypothesis that the input noise is correlated with the measurement noise are derived and can be described in a unified framework. Then, UKF and DDF with correlated noises are proposed on the basis of approximation of the posterior mean and covariance in the unified framework by using unscented transformation and second order Stirling's interpolation. The proposed UKF and DDF with correlated noises break through the limitation that input noise and measurement noise must be assumed to be uneorrelated in standard UKF and DDF. Two simulation examples show the effectiveness and feasibility of new algorithms for dealing with nonlinear filtering issue with correlated noises.展开更多
The ground penetrating radar (GPR) detection data is a wide band signal, always disturbed by some noise, such as ambient random noise and muhiple refleetion waves. The noise affects the target identification of unde...The ground penetrating radar (GPR) detection data is a wide band signal, always disturbed by some noise, such as ambient random noise and muhiple refleetion waves. The noise affects the target identification of underground medium seriously. A method based on principal component analysis (PCA) was proposed to ex- tract the target signal and remove the uncorrelated noise. According to the correlation of signal, the authors get the eigenvalues and corresponding eigenvectors by decomposing the covariance matrix of GPR data and make linear transformation for the GPR data to get the principal components (PCs). The lower-order PCs stand h^r the strong correlated target signals of the raw data, and the higher-order ones present the uneorrelated noise. Thus the authors can extract the target signal and filter uncorrelated noise effectively by the PCA. This method was demonstrated on real ultra-wideband through-wall radar data and simulated GPR data. Both of the results show that the PCA method can effectively extract the GPR target signal and remove the uncorrelated noise.展开更多
The dispersion relation is derived for three-dimensional dust-acoustic waves in a current-driven dusty plasmas with both positively and negatively charged dust particles. The dependencies of the frequency and the grow...The dispersion relation is derived for three-dimensional dust-acoustic waves in a current-driven dusty plasmas with both positively and negatively charged dust particles. The dependencies of the frequency and the growth rate on the wave number K, the intensity of magnetic field B, and the inclination angle θ have been numerically shown in this paper. The growth rate is negative for the laboratory dusty plasma, but it is positive for the cosmic dusty plasma. It is found that when the inclination angle θ = π/2, there is no instability. The effect of the electrostatic field Eo has also been studied in this paper.展开更多
Objective:To determine the relations between endothelium-dependent vasodilator function and blood flow in the brachial and coronary arteries in patients with suspected coronary artery disease.Methods:Twenty-eight pati...Objective:To determine the relations between endothelium-dependent vasodilator function and blood flow in the brachial and coronary arteries in patients with suspected coronary artery disease.Methods:Twenty-eight patients with suspected coronary artery disease underwent brachial artery endothelial function test by using high-resolution B-mode ultrasound before coronary angiography(CAG)and coronary flow reserve(CFR)test by using intracoronary Doppler technique.The correlation of coronary artery dilatation induced by an increase in blood flow after intracoronary adenosine infusion and brachial artery flow-mediated dilatation(FMD) following reactive hyperemia was evaluated.The relation between the change of brachial artery blood flow and CFR was also studied.Results:There was a positive correlation between brachial FMD and percent change of coronary diameter after adenosine infusion(12.50%±9.35% vs 11.38%±7.55%,r=0.425,P=0.02).There was also a weak negative relation between brachial flow change following reactive hy-peremia and CFR(r=-0.397,P=0.04).Conclusion:There is a correlation between the coronary endo-thelial function and the CFR by ultrasonic determination of brachial flow changes following reactive hyperemia.展开更多
基金supported by the National Natural Science Foundation of China(No.41174087,41204089)the National Oil and Gas Major Project(No.2011ZX05005-005)
文摘Prestack reverse time migration(PSTM) is a common imaging method; however low-frequency noises reduce the structural imaging precision. Thus, the suppression of migration noises must be considered. The generation mechanism of low-frequency noises is analyzed and the up-, down-, left-, and right-going waves are separated using the Poynting vector of the acoustic wave equation. The computational complexity and memory capacitance of the proposed method are far smaller than that required when using the conventional separation algorithm of 2D Fourier transform. The normalized wavefield separation crosscorrelation imaging condition is used to suppress low-frequency noises in reverse time migration and improve the imaging precision. Numerical experiments using the Marmousi model are performed and the results show that the up-, down-, left-, and right-going waves are well separated in the continuation of the wavefield using the Poynting vector. We compared the imaging results with the conventional method, Laplacian filtering, and wavefield separation with the 2D Fourier transform. The comparison shows that the migration noises are well suppressed using the normalized wavefield separation cross-correlation imaging condition and higher precision imaging results are obtained.
文摘A noise model for the analog correlator used in the ultra wideband receivers is proposed due to lack of simulation capability on noise performance of the correlator in current EDA tools.The analog correlator circuit is divided into several parts to calculate the equivalent noise sources respectively.The ideal impulse generators,instead of the noise sources,are then applied to obtain the time varying transfer functions.Fourier transforms are carried out to explore the relationship between the noise input and output in frequency domain for each part.Then the symmetrical noise sources are grouped together and the periodicity of the circuit is utilized to further simplify the model.This model can be used to evaluate noise performance of the correlator.
基金Supported by 973 Project of China (No.2002 CB312102)and the National Natural Science Foundation of China (No.60272044).
文摘Two gain forms of spectral amplitude subtraction are derived theoretically without neglecting the correlation of speech and noise spectrum during the period of a fralne. In the implementation, the constrained gain is expressed as a function of noncausal a priori SNR (Signal-to-Noise Ratio). Noise and noncausal a priori SNR are estimated from the multitaper spectrum of the noisy signal with algorithms modified to be suitable for the multitaper spectruln. Objective evaluations show that in case of white Gaussian noise the proposed method outperforms some methods based on LSA (Log Spectral Amplitude) in terms of MBSD (Modified Bark Spectral Distortion), segmental SNR and overall SNR, and informal listening tests show that speech reconstructed in this way has little speech distortion and musical noise is nearly inaudible even at low SNR.
文摘When Kalman filter is used in the estimation of Vasicek term structure of interest rates,it is usual to assume that the measurement noise is uncorrelated.Study results are more favorable to the assumption of correlated measurement noise.An augmented state Kalman filter form for Vasicek model is proposed to optimally estimate the unobservable state variable with the assumption of correlated measurement noise.Empirical results indicate that the model with sequentially correlated measurement noise can more accurately describe the dynamics of the term structure of interest rates.
基金TheDevelopingFoundationofShanghaiScienceandTechnologyCommittee (No .9944 190 2 7) .
文摘A positioning volume ellipsoid method is proposed to represent tumor volume in the workspace of a high-intensity-focused ultrasound (HIFU) surgery platform during the platform's positioning motion. To this simplified tumor model, a nearest neighbor search method is used to determine intermediate configuration and goal configuration, which the treatment head and ultrasound focus must pass in their localization to target volume. Based on the decided configurations, the continuity condition of combined Bezier curve in Euclidean space and De Casteljau algorithm on Lie group SO(3) are integrated to construct a combined Bezier positioning path of C2 continuity at junctional configuration, and an illustration of different positioning path planning is analyzed based on a liver tumor case.
文摘In this paper, the vibration arid sound radiation of the underwater complexshell-structure which is the cylindrical shell with hemi-spherical shell on the ends are studied bystatistical energy analysis (SEA). The whole shell-structure is divided into the four subsystems,and the SEA physical model and power flow balance equations among these subsystems are established.The similitude relations of input power, coupling loss factor and modal density of the subsystemsbetween the complex shell-structure and its scaled-down model are analyzed. According to thesimilitude theory and power flow balance equations, when the immerged shell-structures are excited,the similar relations of spatially averaged vibration response and underwater radiating sound powerare established for the complex shell-structure and its scaled-down model.
文摘We study the steady state properties ofa genotype selection model in presence of correlated Gaussian whitenoise. The effect of the noise on the genotype selection model is discussed. It is found that correlated noise can breakthe balance of gene selection and induce the phase transition which can makes us select one type gene haploid from agene group.
文摘Objective To evaluate the efficacy of minimally invasive perventricular device closure of ventricular septal defect(VSD). Methods Between September 2011 and February 2013, we collected 40 patients who underwent perventricular closure via a small lower sternal incision(minimally invasive group), aged 15.5±3.5 years(12 months to 32 years) with a body weight of 24.2±7.5 kg(10.8-58.0 kg). The mean size of VSD was 5.6±0.5 mm(2-14 mm). Another 40 patients were included as the surgical group, receiving the conventional surgical repair of VSD. The device of the minimally invasive group was released under the guidance of transesophageal echocardiography. Success rate, cardiac indicators, and clinical outcomes of the 2 groups were compared. Results The patients in the surgical group and those in the minimally invasive group showed similar results in success rate(both 97.5%). The procedure time, intensive care unit stay, hospital stay, and postoperative recovery time in the minimally invasive group were significantly shorter than those in the surgical group(58±21 minutes versus 145±26 minutes, 2±1 days versus 8±3 days, 5±1 days versus 16±6 days, 3±1 days versus 90±20 days, all P<0.05). The minimally invasive group had a higher incidence of conduction anomalies(17.5% versus 2.5%, P<0.05). In the follow-up period of 3-12 months, there was no new residual shunt, noticeable aortic regurgitation, significant arrhythmias, or device failure except for new complications in the surgical group. Conclusions The success rate of minimally invasive perventricular device closure of VSD under transesophageal echocardiography guidance is similar to that of conventional surgical repair, but the short-term outcomes of the minimally invasive approach is much better. Long-term follow-up is necessary to confirm the effectiveness of this technique.
文摘A T equivalent high frequency heterojunction bipolar transistor (HBT) noise model is reported.This model is derived from Hawkins noise model commonly used in Si BJT.The main modifications include the influence of the ideality factor,emitter resistance,intrinsic base collector capacitance,extrinsic base collector capacitance and other parasitic elements of HBT represented in equivalent circuit topology.In order to calculate accurate noise parameters from the equivalent circuit,the noise correlation matrix method is used to avoid any simplifications generated in circuit transformations and complex noise measurements.The analysis of the influence of the equivalent circuit elements on the minimum noise figure is reported,the results of analysis agree well with the physics explanations.By means of the formulae derived from device physics of HBT,the influence of device parameters on the minimum noise figure is also represented.
基金Supported by Major State Basic Research Program of China ("973" Program,No. 2011CB610505)Specialized Research Fund for the Doctoral Program of Higher Education (No. 20120032110029)
文摘The degradation process of organosol coated tinplate in beverage was investigated by electrochemical noise (EN) technique combined with morphology characterization.EN data were analyzed using phase space reconstruction theory.With the correlation dimensions obtained from the phase space reconstruction,the chaotic behavior of EN was quantitatively evaluated.The results show that both electrochemical potential noise (EPN) and electrochemical current noise (ECN) have chaotic properties.The correlation dimensions of EPN increase with corrosion extent,while those of ECN seem nearly unchanged.The increased correlation dimensions of EPN during the degradation process are associated with the increased susceptibility to local corrosion.
基金Supported by the National Natural Science Foundation of China(No.61300214)the National Natural Science Foundation of Henan Province(No.132300410148)+1 种基金the Post-doctoral Science Foundation of China(No.2014M551999)the Funding Scheme of Young Key Teacher ofHenan Province Universities(No.2013GGJS-026)
文摘Aiming at the effective realization of particle filter for maneuvering target tracking in multi-sensor measurements,a novel multi-sensor multiple model particle filtering algorithm with correlated noises is proposed.Combined with the kinetic evolution equation of target state,a multi-sensor multiple model particle filter is firstly constructed,which is also used as the basic framework of a new algorithm.In the new algorithm,in order to weaken the adverse influence from random measurement noises in the measuring process of particle weight,a weight optimization strategy is introduced to improve the reliability and stability of particle weight.In addition,considering the correlated noise existing in the practical engineering,a decoupling method of correlated noise is given by the rearrangement and transformation of the state transition equation and measurement equation.Since the weight optimization strategy and noise decoupling method adopt respectively the center fusion structure and the off-line way,it improves the adverse effect effectively on computational complexity for increasing state dimension and sensor number.Finally,the theoretical analysis and experimental results show the feasibility and efficiency of the proposed algorithm.
文摘Molecular dynamics calculation of UO2 in a wide temperature range are presented and dis- cussed. The calculated lattice parameters, mean square displacements, and dynamic prop- erty of phonon-level density of the velocity auto-correlation functions for UO2 are provided. The Morelon potential and the Basak potential are employed. It confirms that the cal- culated lattice parameters using the Basak potential are in nearly perfect agreement with the reported values. The models successfully predict mean square displacement and Bredig transition. Furthermore, the phonon-level density of uranium dioxide are discussed. The intensity of phonon-level density increases with temperature, and the properties of UO2 are characterized by large thermal vibrations rather than extensive disorder.
文摘Background: Until recently it has not been possible to isolate the mechanical behavior of individual muscles during passive stretching. Muscle shear modulus(an index of muscle stiffness) measured using ultrasound shear wave elastography can be used to estimate changes in stiffness of an individual muscle. The aims of the present study were(1) to determine the shear modulus—knee angle relationship and the slack angle of the vastus medialis oblique(VMO), rectus femoris(RF), and vastus lateralis(VL) muscles;(2) to determine whether this differs between the muscles.Methods: Nine male rowers took part in the study. The shear modulus of VMO, RF, and VL muscles was measured while the quadriceps was passively stretched at 3°/s. The relationship between the muscle shear modulus and knee angle was plotted as shear modulus—knee angle curve through which the slack angle of each muscle was determined.Results: The shear modulus of RF was higher than that of VMO and VL when the muscles were stretched over 54°(all p < 0.01). No significant difference was found between the VMO and VL(all p > 0.05). The slack angle was similar among the muscles: 41.3°± 10.6°, 44.3°± 9.1°, and 44.3°± 5.6° of knee flexion for VMO, RF, and VL, respectively(p = 0.626).Conclusion: This is the first study to experimentally determine the muscle mechanical behavior of individual heads of the quadriceps during passive stretching. Different pattern of passive tension was observed between mono-and bi-articular muscles. Further research is needed to determine whether changes in muscle stiffness are muscle-specific in pathological conditions or after interventions such as stretching protocols.
基金Projects(61135001, 61075029, 61074155) supported by the National Natural Science Foundation of ChinaProject(20110491690) supported by the Postdocteral Science Foundation of China
文摘New sigma point filtering algorithms, including the unscented Kalman filter (UKF) and the divided difference filter (DDF), are designed to solve the nonlinear filtering problem under the condition of correlated noises. Based on the minimum mean square error estimation theory, the nonlinear optimal predictive and correction recursive formulas under the hypothesis that the input noise is correlated with the measurement noise are derived and can be described in a unified framework. Then, UKF and DDF with correlated noises are proposed on the basis of approximation of the posterior mean and covariance in the unified framework by using unscented transformation and second order Stirling's interpolation. The proposed UKF and DDF with correlated noises break through the limitation that input noise and measurement noise must be assumed to be uneorrelated in standard UKF and DDF. Two simulation examples show the effectiveness and feasibility of new algorithms for dealing with nonlinear filtering issue with correlated noises.
基金Supported by project of Natural Science Foundation of China(No.41174097)
文摘The ground penetrating radar (GPR) detection data is a wide band signal, always disturbed by some noise, such as ambient random noise and muhiple refleetion waves. The noise affects the target identification of underground medium seriously. A method based on principal component analysis (PCA) was proposed to ex- tract the target signal and remove the uncorrelated noise. According to the correlation of signal, the authors get the eigenvalues and corresponding eigenvectors by decomposing the covariance matrix of GPR data and make linear transformation for the GPR data to get the principal components (PCs). The lower-order PCs stand h^r the strong correlated target signals of the raw data, and the higher-order ones present the uneorrelated noise. Thus the authors can extract the target signal and filter uncorrelated noise effectively by the PCA. This method was demonstrated on real ultra-wideband through-wall radar data and simulated GPR data. Both of the results show that the PCA method can effectively extract the GPR target signal and remove the uncorrelated noise.
文摘The dispersion relation is derived for three-dimensional dust-acoustic waves in a current-driven dusty plasmas with both positively and negatively charged dust particles. The dependencies of the frequency and the growth rate on the wave number K, the intensity of magnetic field B, and the inclination angle θ have been numerically shown in this paper. The growth rate is negative for the laboratory dusty plasma, but it is positive for the cosmic dusty plasma. It is found that when the inclination angle θ = π/2, there is no instability. The effect of the electrostatic field Eo has also been studied in this paper.
文摘Objective:To determine the relations between endothelium-dependent vasodilator function and blood flow in the brachial and coronary arteries in patients with suspected coronary artery disease.Methods:Twenty-eight patients with suspected coronary artery disease underwent brachial artery endothelial function test by using high-resolution B-mode ultrasound before coronary angiography(CAG)and coronary flow reserve(CFR)test by using intracoronary Doppler technique.The correlation of coronary artery dilatation induced by an increase in blood flow after intracoronary adenosine infusion and brachial artery flow-mediated dilatation(FMD) following reactive hyperemia was evaluated.The relation between the change of brachial artery blood flow and CFR was also studied.Results:There was a positive correlation between brachial FMD and percent change of coronary diameter after adenosine infusion(12.50%±9.35% vs 11.38%±7.55%,r=0.425,P=0.02).There was also a weak negative relation between brachial flow change following reactive hy-peremia and CFR(r=-0.397,P=0.04).Conclusion:There is a correlation between the coronary endo-thelial function and the CFR by ultrasonic determination of brachial flow changes following reactive hyperemia.