期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
一种新型固支结构石英音叉陀螺的设计 被引量:2
1
作者 张瀚 金小锋 邹江波 《仪表技术与传感器》 CSCD 北大核心 2009年第B11期313-315,共3页
石英音叉陀螺的固支结构对陀螺器件的性能影响很大。提出一种新型固支结构的石英音叉陀螺,把固支结构的支撑梁设计在元件拾取运动零位移线处,目的在于提高陀螺对外界振动和温度变化的抗干扰能力,从而改善零位稳定性。运用ANSYS软件对新... 石英音叉陀螺的固支结构对陀螺器件的性能影响很大。提出一种新型固支结构的石英音叉陀螺,把固支结构的支撑梁设计在元件拾取运动零位移线处,目的在于提高陀螺对外界振动和温度变化的抗干扰能力,从而改善零位稳定性。运用ANSYS软件对新结构做仿真验证,结果表明新结构在元件灵敏度、抗振动等重要性能上都有一定提高。新结构同时能缩短元件制造流程,更易工程实现。 展开更多
关键词 石英音叉陀螺 内部固支 拾取模态零位移线 ANSYS
下载PDF
Internal fixation with headless compression screws and back buttress plate for treatment of old Hoffa fracture 被引量:7
2
作者 Min Li Tu Chongqi Wang Guanglin Fang Yue Duan Hong Liu Lei Zhang Hui 《Chinese Journal of Traumatology》 CAS CSCD 2014年第2期79-83,共5页
Objective: To analyze the early clinical and radiographic outcomes of Hoffa fractures treated by a standard protocol of open reduction and internal fixation using headless compression screws combined with back buttre... Objective: To analyze the early clinical and radiographic outcomes of Hoffa fractures treated by a standard protocol of open reduction and internal fixation using headless compression screws combined with back buttress plate in a consecutive series of 8 Chinese patients. Methods: Open reduction and internal fixation was performed on all patients. The fractures were anatomical- ly reduced and held temporarily by K-wire. If the ends of fractures were atrophic, autologous bone graft from the ipsilateral iliac crest was packed between the ends. Then the fracture fragments were fixed with AO 6.5 mm headless compression cannulated screws. At least two screws were used to provide rotational stability. One pre-contoured reconstruction plate was placed on the nonarticular surface posteromedially or posterolaterally as back buttress plate. Results: All the patients were followed up for at least 12 months (range 12-25 months). All fractures achieved anatomical reduction and healed clinically and radiographically. At recent follow-up, the mean flexion degree was 120.6° (range 110°-135°) and the mean extension degree was 2.5° (range 0°-5°). The average visual analogue scale score was 1.6 points (range 0-3). Six patients were assessed as excellent and 2 as good according to the hospital for special surgery knee score system. There were no superficial or deep infections, or hardware breakages. No patient had giving way or locking of the knee, though some had intermittent pain and swelling after strenuous exercise. Injury mechanism had significant influence on the functional outcome (P=0.046). Conclusion: Headless compression screws combined with back buttress plate and/or autologous bone grafting to treat old Hoffa fracture is one of effective measures. It would be conducive to not only fracture healing but also early exercise and functional recovery. 展开更多
关键词 Fractures bone Fracture foration internal Intra-articular fractures
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部