This paper presents results on the combustion of syngas fuel in re-circulating vortex combustor. The combustion stability is achieved through the use of cavities in which recirculation zones of hot products generated ...This paper presents results on the combustion of syngas fuel in re-circulating vortex combustor. The combustion stability is achieved through the use of cavities in which recirculation zones of hot products generated by the direct injection of fuel and air are created and acting as a continuous source of ignition for the incoming main fuel-air stream. CFD (computational fluid dynamics) analysis was performed in this study to test the combustion performance and emissions from the vortex trapped combustor using synthetic gas or syngas fuel produced from the gasification process. The flame temperature, the flow field and species concentrations inside the vortex trapped combustor were obtained. Several syngas fuels with different fuel compositions (H2, CO, CH4, CO2, N2 and H20) and lower heating values were tested in this study. The changes on the flame temperature and species concentrations inside the combustor, the emissions of NOx, CO, CO2 at the exit of the combustor, the combustor efficiency and the total pressure drop for syngas fuels are presented in this paper. The effect of H2/CO ratio and the mass fraction of each constituent of syngas fuels and hydrogen-methane fuel mixtures on the combustion and emissions performances were investigated.展开更多
An integrated program was established to design a combustor for a liquid rocket engine and to analyze regenerative cooling results on a preliminary design level.Properties of burnt gas from a kerosene-LOx mixture in t...An integrated program was established to design a combustor for a liquid rocket engine and to analyze regenerative cooling results on a preliminary design level.Properties of burnt gas from a kerosene-LOx mixture in the combustor and rocket performance were calculated from CEA which is the code for the calculation of chemical equilibrium.The heat transfer of regenerative cooling was analyzed by using SUPERTRAPP code for coolant properties and by one-dimensional correlations of the heat transfer coefficient from the combustor liner to the coolant.Profiles of the combustors of F-1 and RS-27A engines were designed from similar input data and the present results were compared to actual data for validation.Finally,the combustors of 30 tonf class,75 tonf class and 150 tonf class were designed from the required thrust,combustion chamber,exit pressure and mixture ratio of propellants.The wall temperature,heat flux and pressure drop were calculated for heat transfer analysis of regenerative cooling using the profiles.展开更多
文摘This paper presents results on the combustion of syngas fuel in re-circulating vortex combustor. The combustion stability is achieved through the use of cavities in which recirculation zones of hot products generated by the direct injection of fuel and air are created and acting as a continuous source of ignition for the incoming main fuel-air stream. CFD (computational fluid dynamics) analysis was performed in this study to test the combustion performance and emissions from the vortex trapped combustor using synthetic gas or syngas fuel produced from the gasification process. The flame temperature, the flow field and species concentrations inside the vortex trapped combustor were obtained. Several syngas fuels with different fuel compositions (H2, CO, CH4, CO2, N2 and H20) and lower heating values were tested in this study. The changes on the flame temperature and species concentrations inside the combustor, the emissions of NOx, CO, CO2 at the exit of the combustor, the combustor efficiency and the total pressure drop for syngas fuels are presented in this paper. The effect of H2/CO ratio and the mass fraction of each constituent of syngas fuels and hydrogen-methane fuel mixtures on the combustion and emissions performances were investigated.
基金supported by the Output-oriented Project of Collaborative Research Program with Higher Education Partners of Korea Aerospace Research Insti-tute in 2009
文摘An integrated program was established to design a combustor for a liquid rocket engine and to analyze regenerative cooling results on a preliminary design level.Properties of burnt gas from a kerosene-LOx mixture in the combustor and rocket performance were calculated from CEA which is the code for the calculation of chemical equilibrium.The heat transfer of regenerative cooling was analyzed by using SUPERTRAPP code for coolant properties and by one-dimensional correlations of the heat transfer coefficient from the combustor liner to the coolant.Profiles of the combustors of F-1 and RS-27A engines were designed from similar input data and the present results were compared to actual data for validation.Finally,the combustors of 30 tonf class,75 tonf class and 150 tonf class were designed from the required thrust,combustion chamber,exit pressure and mixture ratio of propellants.The wall temperature,heat flux and pressure drop were calculated for heat transfer analysis of regenerative cooling using the profiles.