Bulk anisotropic Nd-Fe-B magnets were prepared from hydrogen-disproportionation-desorption-recombination(HDDR) powders via spark plasma sintering(SPS) and subsequent hot deformation. The influence of sintering tem...Bulk anisotropic Nd-Fe-B magnets were prepared from hydrogen-disproportionation-desorption-recombination(HDDR) powders via spark plasma sintering(SPS) and subsequent hot deformation. The influence of sintering temperature on the structure and magnetic properties of the spark plasma sintered Nd-Fe-B magnets were studied. The remanence Br, intrinsic coercivity Hcj, and the maximum energy product(BH)max, of sintered Nd-Fe-B magnets first increase and then decrease with the increase of sintering temperature, TSPS, from 650 °C to 900 °C. The optimal magnetic properties can be obtained when TSPS is 800 °C. The Nd-Fe-B magnet sinter treated at 800 °C was subjected to further hot deformation. Compared with the starting HDDR powders or the SPS treated magnets, the hot-deformed magnets present more obvious anisotropy and possess much better magnetic properties due to the good c-axis texture formed in the deformation process. The anisotropic magnet deformed at 800 °C with 50% compression ratio has a microstructure consisting of well aligned and platelet-shaped Nd2Fe14 B grains without abnormal grain growth and exhibits excellent magnetic properties parallel to the pressing axis.展开更多
A novel magnetic adsorbent was synthesized by magnetizing bentonite by APTES-Fe_3O_4 via a functional groupbridged interaction. The characterization of APTES-Fe_3O_4/bentonite was conducted via transmission electron m...A novel magnetic adsorbent was synthesized by magnetizing bentonite by APTES-Fe_3O_4 via a functional groupbridged interaction. The characterization of APTES-Fe_3O_4/bentonite was conducted via transmission electron microscope(TEM), X-ray diffraction(XRD), Fourier transform infrared spectrophotometer(FT-IR), thermal gravimetric analysis(TGA), vibrating sample magnetometer(VSM), zeta potential analysis and Brunner–Emmet–Teller(BET). The APTES-Fe_3O_4/bentonite was assessed as adsorbents for methylene blue(MB) with a high adsorption capacity(91.83 mg·g^(-1)). Factors affecting the adsorption of MB(such as p H, equilibrium time, temperature and initial concentration) were investigated. The adsorption process completely reaches equilibrium after 120 min and the maximum sorption is achieved at p H 8.0. The adsorption trend follows the pseudosecond order kinetics model. The adsorption data gives good fits with Langmuir isotherm model. The parameter factor RLfalls between 0 and 1, indicating the adsorption of MB is favorable. The adsorption process is endothermic with positive ΔH^0 values. The positive values of ΔG^0 confirm the affinity of the adsorbent towards MB, and suggest an increased randomness at the solid–liquid interface during the adsorption process. Regeneration of the saturated adsorbent was easily carried out via gamma-irradiation.展开更多
To reveal the deformation process of the middle Yangtze fold belt, we conducted a paleomagnetic study on Middle Triassic limestones and Middle to Late Jurassic sandstones from Wanzhou, Chongqing. Stepwise thermal and ...To reveal the deformation process of the middle Yangtze fold belt, we conducted a paleomagnetic study on Middle Triassic limestones and Middle to Late Jurassic sandstones from Wanzhou, Chongqing. Stepwise thermal and alternating field demagnetization were used to isolate the multi-component re- manent magnetizations. The Jurassic samples were overprinted by recent geomagnetic field, while three magnetization components were isolated from the Middle Triassic samples. A low temperature component (LTC) was isolated at temperatures below 200℃, an intermediate temperature component (ITC) at 200―360℃ and a high temperature component (HTC) at 400―460℃. The LTC is distributed around the present-day Earth magnetic field, probably a viscous component. Stepwise unfolding indi- cates that the maximum precision parameters of ITC and HTC components are achieved at 33±8% and 50±27% (with 95% confidence) unfolding, respectively. The best-clustered ITC mean direction, Dec = 11.2°, Inc = 45.2° (α95 = 4.5°, N = 34), corresponding to a paleopole at 79.3°N, 219.5°E (dp = 3.6°, dm = 5.7°), is consistent with the Cretaceous reference direction of the South China Block (SCB). The best-clustered HTC mean direction (taking 70% unfolding), Dec = 24.2°, Inc =49.0° (α95 = 3.6°, N = 23), corresponding to a paleopole at 69.2°N, 195.5°E (dp =3.1°, dm = 4.8°), suggests a clockwise rotation of 12.8°±3.5°. These synfolding remagnetization components clearly reveal that a clockwise rotation happened at the middle stage of folding, thus supporting that at least part of the variation in fold axis strikes is due to orocline rotation. Combined with published data, our analysis indicates that the Wan- zhou-Xiangxi segment of the middle Yangtze fold belt experienced oroclinal bending. Furthermore, a published post-folding component isolated from the Middle Triassic Puqi Formation suggests a 27.5°±5.8° clockwise rotation, confirming that at least 50% of the observed clockwise rotations in the eastern middle Yangtze fold belt can be attributed to oroclinal bending. The remagnetization data and geological evidence observed in the middle Yangtze fold belt suggest that collision between SCB and North China Block (NCB) probably lasted till the early period of Early Cretaceous.展开更多
Objective To investigate the effects of magnetic stents on coronary restenosis after percutaneous transluminal coronary angioplasty (PTCA). Methods Twenty dogs were randomly divided into the control and experimental...Objective To investigate the effects of magnetic stents on coronary restenosis after percutaneous transluminal coronary angioplasty (PTCA). Methods Twenty dogs were randomly divided into the control and experimental groups, each with 10 dogs. The control group was given common Palmaz-stents in the 6-8 segment of left anterior descending coronary artery or in the 11-14 segment of the left circumflexus. The experimental group was given magnetic stents in the same parts of the coronary arteries. The dogs were not given antiplatelet or anticoagulant drugs before or after the operation. Six months later, the 20 dogs were subjected to coronary angiographies, and then were sacrificed. Three centimeter long segments of the target vessels were cut for pathological examination. Results The degree of restenosis in 3 dogs of the control group was more than 50%, but none in the experimental group experienced restenosis. The average thickness of the tunica intima of the target artery was 2.98±0.56?mm in the control and 1.13±0.41?mm in the experimental group (P<0.05). Conclusion Magnetic stents could have a significant preventive effect on coronary restenosis.展开更多
基金Project(NCET-10-0364)supported by the Program for New Century Excellent Talents in University,ChinaProject(2012ZG0006)supported by the Fundamental Research Funds for the Central Universities,ChinaProject(51174095)supported the National Natural Science Foundation of China
文摘Bulk anisotropic Nd-Fe-B magnets were prepared from hydrogen-disproportionation-desorption-recombination(HDDR) powders via spark plasma sintering(SPS) and subsequent hot deformation. The influence of sintering temperature on the structure and magnetic properties of the spark plasma sintered Nd-Fe-B magnets were studied. The remanence Br, intrinsic coercivity Hcj, and the maximum energy product(BH)max, of sintered Nd-Fe-B magnets first increase and then decrease with the increase of sintering temperature, TSPS, from 650 °C to 900 °C. The optimal magnetic properties can be obtained when TSPS is 800 °C. The Nd-Fe-B magnet sinter treated at 800 °C was subjected to further hot deformation. Compared with the starting HDDR powders or the SPS treated magnets, the hot-deformed magnets present more obvious anisotropy and possess much better magnetic properties due to the good c-axis texture formed in the deformation process. The anisotropic magnet deformed at 800 °C with 50% compression ratio has a microstructure consisting of well aligned and platelet-shaped Nd2Fe14 B grains without abnormal grain growth and exhibits excellent magnetic properties parallel to the pressing axis.
基金Supported by the National Natural Science Foundation of China(61601227)the Natural Science Foundation of Jiangsu Province(BK20160939)+1 种基金the Natural Science Foundation of the Jiangsu Higher Education Institutions of China(16KJB180010)the Qing Lan Project and Priority Academic Program Development of Jiangsu Higher Education Institutions(PAPD)
文摘A novel magnetic adsorbent was synthesized by magnetizing bentonite by APTES-Fe_3O_4 via a functional groupbridged interaction. The characterization of APTES-Fe_3O_4/bentonite was conducted via transmission electron microscope(TEM), X-ray diffraction(XRD), Fourier transform infrared spectrophotometer(FT-IR), thermal gravimetric analysis(TGA), vibrating sample magnetometer(VSM), zeta potential analysis and Brunner–Emmet–Teller(BET). The APTES-Fe_3O_4/bentonite was assessed as adsorbents for methylene blue(MB) with a high adsorption capacity(91.83 mg·g^(-1)). Factors affecting the adsorption of MB(such as p H, equilibrium time, temperature and initial concentration) were investigated. The adsorption process completely reaches equilibrium after 120 min and the maximum sorption is achieved at p H 8.0. The adsorption trend follows the pseudosecond order kinetics model. The adsorption data gives good fits with Langmuir isotherm model. The parameter factor RLfalls between 0 and 1, indicating the adsorption of MB is favorable. The adsorption process is endothermic with positive ΔH^0 values. The positive values of ΔG^0 confirm the affinity of the adsorbent towards MB, and suggest an increased randomness at the solid–liquid interface during the adsorption process. Regeneration of the saturated adsorbent was easily carried out via gamma-irradiation.
基金Supported by the National Natural Science Foundation of China (Grant No. 40374023)the "Hundred Talents Project" of CAS
文摘To reveal the deformation process of the middle Yangtze fold belt, we conducted a paleomagnetic study on Middle Triassic limestones and Middle to Late Jurassic sandstones from Wanzhou, Chongqing. Stepwise thermal and alternating field demagnetization were used to isolate the multi-component re- manent magnetizations. The Jurassic samples were overprinted by recent geomagnetic field, while three magnetization components were isolated from the Middle Triassic samples. A low temperature component (LTC) was isolated at temperatures below 200℃, an intermediate temperature component (ITC) at 200―360℃ and a high temperature component (HTC) at 400―460℃. The LTC is distributed around the present-day Earth magnetic field, probably a viscous component. Stepwise unfolding indi- cates that the maximum precision parameters of ITC and HTC components are achieved at 33±8% and 50±27% (with 95% confidence) unfolding, respectively. The best-clustered ITC mean direction, Dec = 11.2°, Inc = 45.2° (α95 = 4.5°, N = 34), corresponding to a paleopole at 79.3°N, 219.5°E (dp = 3.6°, dm = 5.7°), is consistent with the Cretaceous reference direction of the South China Block (SCB). The best-clustered HTC mean direction (taking 70% unfolding), Dec = 24.2°, Inc =49.0° (α95 = 3.6°, N = 23), corresponding to a paleopole at 69.2°N, 195.5°E (dp =3.1°, dm = 4.8°), suggests a clockwise rotation of 12.8°±3.5°. These synfolding remagnetization components clearly reveal that a clockwise rotation happened at the middle stage of folding, thus supporting that at least part of the variation in fold axis strikes is due to orocline rotation. Combined with published data, our analysis indicates that the Wan- zhou-Xiangxi segment of the middle Yangtze fold belt experienced oroclinal bending. Furthermore, a published post-folding component isolated from the Middle Triassic Puqi Formation suggests a 27.5°±5.8° clockwise rotation, confirming that at least 50% of the observed clockwise rotations in the eastern middle Yangtze fold belt can be attributed to oroclinal bending. The remagnetization data and geological evidence observed in the middle Yangtze fold belt suggest that collision between SCB and North China Block (NCB) probably lasted till the early period of Early Cretaceous.
文摘Objective To investigate the effects of magnetic stents on coronary restenosis after percutaneous transluminal coronary angioplasty (PTCA). Methods Twenty dogs were randomly divided into the control and experimental groups, each with 10 dogs. The control group was given common Palmaz-stents in the 6-8 segment of left anterior descending coronary artery or in the 11-14 segment of the left circumflexus. The experimental group was given magnetic stents in the same parts of the coronary arteries. The dogs were not given antiplatelet or anticoagulant drugs before or after the operation. Six months later, the 20 dogs were subjected to coronary angiographies, and then were sacrificed. Three centimeter long segments of the target vessels were cut for pathological examination. Results The degree of restenosis in 3 dogs of the control group was more than 50%, but none in the experimental group experienced restenosis. The average thickness of the tunica intima of the target artery was 2.98±0.56?mm in the control and 1.13±0.41?mm in the experimental group (P<0.05). Conclusion Magnetic stents could have a significant preventive effect on coronary restenosis.