Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Base...Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.展开更多
Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiogr...Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiography without oral metoprolol preparation was prospectively performed in 600 patients.Calcium scoring with plain scan images as well as multi-planar reconstruction(MPR),maximum intensity projection(MIP),and volume rendering technique(VRT) reconstruction with enhanced scan images were performed in all cases.The scan technique and post-reconstruction experience was summarized.The image quality was classified as 1 to 4 points,and coronary segments classified according to the American Heart Association standards were evaluated.Results The average calcium score of the 600 cases was 213.6±298.7(0-3 216.5).The average heart rate of the enhanced scan was 82.1±16.2(47-139) bpm.The post-reconstruction methods with which coronary segments could be shown as best as possible consisted of single phase reconstruction method,two or more phases supplemented method,and electrocardiogram editing method.Altogether 8 457 coronary segments were evaluated,among which 97.2% were evaluated as point 1,1.7% point 2,0.5% point 3,and 0.6% point 4.The coronary segments in 261 cases were completely normal,while 360 segments were diagnosed with <50% stenosis and 625 segments with ≥50% stenosis.Conclusions Excellent coronary artery image can be obtained with dual source CT in patients with any heart rate without oral metoprolol preparation.Heart rate is not a major source of the artifact,coronary segments can be well shown with single or multiple-phase reconstruction method.展开更多
Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acqu...Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv,P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique.展开更多
Objective: To explore the relationship between C-reactive protein(CRP) concentration and severity of coronary artery lesion. Methods: The plasma CRP concentration were tested in 166 cases who underwent coronary angiog...Objective: To explore the relationship between C-reactive protein(CRP) concentration and severity of coronary artery lesion. Methods: The plasma CRP concentration were tested in 166 cases who underwent coronary angiography(CAG),coronary heart disease(CHD) was presented in 86 patients and absent in 80 cases as normal control group, and results of the two groups and different numbers of diseased coronary vessels in CHD group were analyzed. Results: The plasma CRP concentration were 2293±198, 5126±508, 12969±1076 μg/L, respectively,for the normal control group, the stable angina group and the unstable angina group. The CRP concentration in the stable angina group and unstable angina group were significantly higher than those of the normal control group (P<0.05, P<0.01, respectively). In the CHD group, the plasma CRP concentration were 5131±513, 7024±689, 11970±2075 μg/L, respectively,for the 1-vessel-disease-group, the 2-vessel-disease-group and the 3-vessel-disease-group. The CRP concentration of the three groups were significantly higher than those of the normal control group (P<0.01). Conclusion: CRP concentration is closely associated with severity of coronary artery lesion.展开更多
Objective: The aim of the present study was to assess the early clinical outcome and risk factors in old patients with acute ST elevation myocardial infarction (STEMI) following primary percutaneous coronary intervent...Objective: The aim of the present study was to assess the early clinical outcome and risk factors in old patients with acute ST elevation myocardial infarction (STEMI) following primary percutaneous coronary intervention (PCI). Methods: A total of 136 patients older than 60 years with STEMI who received successful PCI were included in this study. The patients were classified in 2 age groups: patients ≥75 years and <75 years of age. The extent of coronary artery lesions was measured by quantitative coronary artery angiography (QCA). Subjects were tracked for subsequent cardiovascular events: cardiac death, myocardial infarction, heart failure, percutaneous coronary intervention, coronary artery bypass and stroke. Results: Though the older group had a higher prevalence of adverse baseline characteristics and lower final TIMI flow than patients<75y (P<0.05), the procedural success did not make difference between the two groups. In 12 months follow-up of 136 study participants, there occurred 39 CV events : cardiac death (five patients), heart failure (nineteen patients), and stroke (six patients). Three patients received coronary bypass grafts and six patients underwent PCI. Heart failure and overall cardiovascular event rates were higher in older patients compared with those in patients<75y. The main adverse clinical events (MACE) for the old group were a little higher comparing with the younger in 12-month follow-up (P=0.029 6 and P=0.043 4). Multivariate cox analysis identified that a diagnosis of diabetes (HR 2.495, 95%CI 1.224 to 5.083, P= 0.011 8) and time from symptom(HR 1.450, 95%CI 1.143 to 1.841, P= 0.008 2) to PCI as independent predictors of CV events after adjustment of all entered baseline variables. Conclusion: Our study suggests that drug-eluting stent implantation in older patients with acute ST elevation myocardial infarction has high initial procedural success rates despite having more severe baseline risk characteristics, and to shorten the time from symptom onset to PCI may decrease cardiovascular events in old patients following PCI.展开更多
文摘Objective To observe value of 0D-1D coupling model and 3D fluid-structure interaction(FSI)model based on coronary CT angiography(CCTA)for displaying hemodynamic characteristics of coronary artery stenosis.Methods Based on CCTA data of the stenosed left anterior descending branch(LAD)in a patient with coronary heart disease,an 0D-1D coupling model and 3D FSI model were built,respectively.Then hemodynamic characteristic indexes,including the pressure,flow velocity and wall shear stress(WSS)were obtained in every 0.01 s during 1 s at 5 sampling points(i.e.sampling point 1—5)using these 2 models,respectively,and the consistencies of the results between models were evaluated with Spearman correlation coefficient r s.Results The time consuming for construction of 0D-1D coupling model and 3D FSI model was 0.033 min and 704 min,respectively.Both models showed basically distribution of the pressure,flow velocity and WSS of the stenosed LAD.For more details,the pressure at the stenosed segment of LAD and the proximal segment of stenosis were both higher,which gradually decreased at the distal segment of stenosis,and the flow velocity at the proximal segment of stenosis was in a relatively slow and uniform condition,with significantly increased flow velocity and WSS at the stenosed segment.Compared with 3D FSI model,0D-1D vascular coupling model was relatively unrefined and lack of distal flow lines when displaying blood flow velocity.For sampling point 2 at the stenosed segment of LAD,no significant consistency for pressure between 2 models was found(P=0.118),but strong consistency for the flow velocity and WSS(r s=0.730,0.807,both P<0.05).The consistencies of pressure,flow velocity and WSS between 2 models at the proximal and distal segment of stenosis,i.e.1,3—5 sampling points were week to moderate(r s=0.237—0.669,all P<0.05).Conclusion 0D-1D coupling model exhibited outstanding computational efficiency and might provide relatively reasonable results,while 3D FSI model showed higher accuracy for details and streamline when simulating LAD stenosis.
文摘Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiography without oral metoprolol preparation was prospectively performed in 600 patients.Calcium scoring with plain scan images as well as multi-planar reconstruction(MPR),maximum intensity projection(MIP),and volume rendering technique(VRT) reconstruction with enhanced scan images were performed in all cases.The scan technique and post-reconstruction experience was summarized.The image quality was classified as 1 to 4 points,and coronary segments classified according to the American Heart Association standards were evaluated.Results The average calcium score of the 600 cases was 213.6±298.7(0-3 216.5).The average heart rate of the enhanced scan was 82.1±16.2(47-139) bpm.The post-reconstruction methods with which coronary segments could be shown as best as possible consisted of single phase reconstruction method,two or more phases supplemented method,and electrocardiogram editing method.Altogether 8 457 coronary segments were evaluated,among which 97.2% were evaluated as point 1,1.7% point 2,0.5% point 3,and 0.6% point 4.The coronary segments in 261 cases were completely normal,while 360 segments were diagnosed with <50% stenosis and 625 segments with ≥50% stenosis.Conclusions Excellent coronary artery image can be obtained with dual source CT in patients with any heart rate without oral metoprolol preparation.Heart rate is not a major source of the artifact,coronary segments can be well shown with single or multiple-phase reconstruction method.
基金Supported by the Ministry of Science and Technology of Inner Mongolia, China (20110504)
文摘Objective To investigate the feasibility of acquiring the similar homogeneous enhancement using bolus-tracking techniques with shortened respiratory time in prospectively electrocardiogram-gated high-pitch spiral acquisition mode (Flash mode) coronary computed tomography angiography (CCTA) compared with test bolus technique. Methods One hundred and eighty-four consecutive patients with mean heart rate ≤65 beats per minute undergoing CCTA were prospectively included in this study. The patients were randomly divided into two groups. Patients in the group A (n=92) instructed to shorten respiratory time received CCTA using bolus-tracking technique with high-pitch spiral acquisition mode (Flash mode), while those in the group B (n=92) underwent CCTA with test bolus technique. The attenuation in the ascending aorta, image noise, contrast-to-noise ratio and radiation doses of the two groups were assessed. Results There were no significant differences in the mean attenuation values in the ascending aorta (483.18±59.07 HU vs. 498.7±83.51 HU, P=0.183), image noise (21.4±4.5 HU vs. 20.9±4.3 HU, P=0.414), contrast-to-noise ratio (12.1±4.2 vs. 13.8±5.1, P=0.31) between the groups A and B. There were no significant differences in the radiation dose of dynamic monitoring scans (0.056±0.026 mSv vs. 0.062±0.018 mSv, P=0.068) and radiation dose of angiography (0.94±0.07 mSv vs. 0.96±0.15 mSv,P=0.926) between the two groups, while 15 mL less contrast material volume was administered in the group A than the group B. Conclusion Bolus-tracking technique with shortened time of respiratory in Flash mode of dual-source CT yields the similar homogeneous enhancement with less contrast material in comparison to the test bolus technique.
文摘Objective: To explore the relationship between C-reactive protein(CRP) concentration and severity of coronary artery lesion. Methods: The plasma CRP concentration were tested in 166 cases who underwent coronary angiography(CAG),coronary heart disease(CHD) was presented in 86 patients and absent in 80 cases as normal control group, and results of the two groups and different numbers of diseased coronary vessels in CHD group were analyzed. Results: The plasma CRP concentration were 2293±198, 5126±508, 12969±1076 μg/L, respectively,for the normal control group, the stable angina group and the unstable angina group. The CRP concentration in the stable angina group and unstable angina group were significantly higher than those of the normal control group (P<0.05, P<0.01, respectively). In the CHD group, the plasma CRP concentration were 5131±513, 7024±689, 11970±2075 μg/L, respectively,for the 1-vessel-disease-group, the 2-vessel-disease-group and the 3-vessel-disease-group. The CRP concentration of the three groups were significantly higher than those of the normal control group (P<0.01). Conclusion: CRP concentration is closely associated with severity of coronary artery lesion.
文摘Objective: The aim of the present study was to assess the early clinical outcome and risk factors in old patients with acute ST elevation myocardial infarction (STEMI) following primary percutaneous coronary intervention (PCI). Methods: A total of 136 patients older than 60 years with STEMI who received successful PCI were included in this study. The patients were classified in 2 age groups: patients ≥75 years and <75 years of age. The extent of coronary artery lesions was measured by quantitative coronary artery angiography (QCA). Subjects were tracked for subsequent cardiovascular events: cardiac death, myocardial infarction, heart failure, percutaneous coronary intervention, coronary artery bypass and stroke. Results: Though the older group had a higher prevalence of adverse baseline characteristics and lower final TIMI flow than patients<75y (P<0.05), the procedural success did not make difference between the two groups. In 12 months follow-up of 136 study participants, there occurred 39 CV events : cardiac death (five patients), heart failure (nineteen patients), and stroke (six patients). Three patients received coronary bypass grafts and six patients underwent PCI. Heart failure and overall cardiovascular event rates were higher in older patients compared with those in patients<75y. The main adverse clinical events (MACE) for the old group were a little higher comparing with the younger in 12-month follow-up (P=0.029 6 and P=0.043 4). Multivariate cox analysis identified that a diagnosis of diabetes (HR 2.495, 95%CI 1.224 to 5.083, P= 0.011 8) and time from symptom(HR 1.450, 95%CI 1.143 to 1.841, P= 0.008 2) to PCI as independent predictors of CV events after adjustment of all entered baseline variables. Conclusion: Our study suggests that drug-eluting stent implantation in older patients with acute ST elevation myocardial infarction has high initial procedural success rates despite having more severe baseline risk characteristics, and to shorten the time from symptom onset to PCI may decrease cardiovascular events in old patients following PCI.