CO2 removal from biogas by water washing system was investigated with various parameters, including liquid/ gas ratio, pressure, temperature, and CO2 content. The results indicate that CO2 removal ratio could reach 34...CO2 removal from biogas by water washing system was investigated with various parameters, including liquid/ gas ratio, pressure, temperature, and CO2 content. The results indicate that CO2 removal ratio could reach 34.6%- 94.2% as liquid/gas ratio increased from 0.14 to 0.50. Increasing pressure (from 0.8 to 1.2 MPa) could improve gas purification with a constant inflow rate of gas. Temperature played a key role in the process and lower temper- ature in absorption tower was beneficial for reducing CO2 content. CO2 removal ratio could reach 24.4%-83.2% when CO2 content in the simulated gas was 25%-45%. The lowest CO2 content after absorption was 2.6% at 1.2 MPa with 400 L·h-1 gas flow and 200 L·h-1 water flow, which meets the requirement of CO2 content in natural Ras for vehicle fuel.展开更多
To better remove the contamination on the surface of a heat-exchanger in urban sewage source heat pump system (USSHPS), this paper analyzes the feasibility of strong self-flushing on the basis of experiments and pre...To better remove the contamination on the surface of a heat-exchanger in urban sewage source heat pump system (USSHPS), this paper analyzes the feasibility of strong self-flushing on the basis of experiments and presents a new on-line self-flushing technique, which alternately flushes part of heat transfer tubes. In addition, operation principles and the structure of the new heat-exchanger are introduced and the feasible economi- cal and technological cleaning plans are given by design calculation and scheme comparison. The result shows that keeping each tube washed for one minute with 5 m/s, the operating cost is lower than ¥5 and when one flushing pump ahemately flushes 10-20 heat exchangers, the saved costs of flushing 10 tubes alternately are over 4 times of the increased costs.展开更多
基金Supported by the National Technology Research and Development Program of China(2008AA062402)the China-US International Cooperation Project(2011DFA90800)the Ministry of Science and Technology,China
文摘CO2 removal from biogas by water washing system was investigated with various parameters, including liquid/ gas ratio, pressure, temperature, and CO2 content. The results indicate that CO2 removal ratio could reach 34.6%- 94.2% as liquid/gas ratio increased from 0.14 to 0.50. Increasing pressure (from 0.8 to 1.2 MPa) could improve gas purification with a constant inflow rate of gas. Temperature played a key role in the process and lower temper- ature in absorption tower was beneficial for reducing CO2 content. CO2 removal ratio could reach 24.4%-83.2% when CO2 content in the simulated gas was 25%-45%. The lowest CO2 content after absorption was 2.6% at 1.2 MPa with 400 L·h-1 gas flow and 200 L·h-1 water flow, which meets the requirement of CO2 content in natural Ras for vehicle fuel.
基金Sponsored by the National Natural Science Foundation of China (Grant No.50578048)
文摘To better remove the contamination on the surface of a heat-exchanger in urban sewage source heat pump system (USSHPS), this paper analyzes the feasibility of strong self-flushing on the basis of experiments and presents a new on-line self-flushing technique, which alternately flushes part of heat transfer tubes. In addition, operation principles and the structure of the new heat-exchanger are introduced and the feasible economi- cal and technological cleaning plans are given by design calculation and scheme comparison. The result shows that keeping each tube washed for one minute with 5 m/s, the operating cost is lower than ¥5 and when one flushing pump ahemately flushes 10-20 heat exchangers, the saved costs of flushing 10 tubes alternately are over 4 times of the increased costs.