期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
评价小型空调器性能的状态标志函数
1
作者 傅明星 曹琦 +1 位作者 刘顺波 王宜义 《暖通空调》 EI 北大核心 1998年第3期44-46,共3页
分析了现有空调器性能评价指标的不足,提出了评价空调器性能的状态标志函数SCF。SCF与空调器的过热度、过冷度、蒸发温度、冷凝温度、压缩机温度有关,它既能够说明空调器无效耗能的多少和空调器能效比高低的原因,又可以用于状... 分析了现有空调器性能评价指标的不足,提出了评价空调器性能的状态标志函数SCF。SCF与空调器的过热度、过冷度、蒸发温度、冷凝温度、压缩机温度有关,它既能够说明空调器无效耗能的多少和空调器能效比高低的原因,又可以用于状态的优化控制和故障诊断,作为微观评价指标,它与现有评价指标能效比结合,将使空调器的性能评价体系更为合理。 展开更多
关键词 空调器 能效比 变频控制 冷冷量 状态标志函数
下载PDF
Studies on Benign Working Pairs for Adsorption Refrigeration 被引量:1
2
作者 崔群 陈海军 姚虎卿 《Journal of Southeast University(English Edition)》 EI CAS 2002年第3期283-288,共6页
Water and ethanol were selected as refrigerants, 13x molecular sieve, silica gel, activated carbon and adsorbents NA and NB prepared by authors were selected as adsorbents, and the performance of adsorption working pa... Water and ethanol were selected as refrigerants, 13x molecular sieve, silica gel, activated carbon and adsorbents NA and NB prepared by authors were selected as adsorbents, and the performance of adsorption working pairs in adsorption refrigeration system was studied. The adsorption isotherms of adsorbents (NA and NB) were obtained by high vacuum gravimetric method. Desorption properties of adsorbents were analyzed and compared by thermal analysis method. The performance parameters of adsorption refrigerat... 展开更多
关键词 adsorption refrigeration working pairs ISOTHERM refrigeration volume
下载PDF
Optimum control strategy for all-variable speed chiller plant 被引量:3
3
作者 蒋小强 龙惟定 李敏 《Journal of Central South University》 SCIE EI CAS 2011年第2期573-579,共7页
The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation ... The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation model of water source chiller plant established in dynamic transient simulation program (TRNSYS),the four-variable quadratic orthogonal regression experiments were carried out by taking cooling load,cooling water supply temperature,cooling water flow rate and chilled water flow rate as variables,and the fitting formulas expressing the relationships between the total energy consumption of chiller plant with the four selected parameters was obtained. With the SAS statistical software and MATHEMATICA mathematical software,the optimal chilled water flow rate and cooling water flow rate which result in the minimum total energy consumption were determined under continuously varying cooling load and cooling water supply temperature. With regard to a chiller plant serving an office building in Shanghai,the total energy consumptions under different control strategies were computed in terms of the forecasting function of cooling load and water source temperature. The results show that applying the optimal control strategy to the chiller plant can bring a saving of 23.27% in power compared with the corresponding conventional variable speed plant,indicating that the optimal control strategy can improve the energy efficiency of chiller plant. 展开更多
关键词 chiller plant control strategy variable speed cooling water flow rate chilled water flow rate
下载PDF
Influence of thermal flow field of cooling tower on recirculation ratio of a direct air-cooled system for a power plant
4
作者 Zhao Wanli Liu Peiqing 《Engineering Sciences》 EI 2008年第4期64-70,共7页
In order to get thermal flow field of direct air-cooled system,the hot water was supplied to the model of direct air-cooled condenser(ACC). The particle image velocimetery (PIV) experiments were carried out to get the... In order to get thermal flow field of direct air-cooled system,the hot water was supplied to the model of direct air-cooled condenser(ACC). The particle image velocimetery (PIV) experiments were carried out to get thermal flow field of a ACC under different conditions in low velocity wind tunnel,at the same time,the recirculation ratio at cooling tower was measured,so the relationship between flow field characteristics and recirculation ratio of cooling tower can be discussed. From the results we can see that the flow field configuration around cooling tower has great effects on average recirculation ratio under cooling tower. The eddy formed around cooling tower is a key reason that recirculation produces. The eddy intensity relates to velocity magnitude and direction angle,and the configuration of eddy lies on the geometry size of cooling tower. So changing the flow field configuration around cooling tower reasonably can decrease recirculation ratio under cooling tower,and heat dispel effect of ACC can also be improved. 展开更多
关键词 direct air-cooled condenser thermal flow field characteristics recirculation ratio PIV experiment
下载PDF
Application of Taguchi Method for the Optimization of System Parameters of Centrifugal Evaporative Air Cooler 被引量:6
5
作者 K.Senthilkumar PSS.Srinivasan 《Journal of Thermal Science》 SCIE EI CAS CSCD 2010年第5期473-479,共7页
A new evaporative cooling system based on the action of centrifugal forces is proposed.Such systems are suitable for cooling large air volumes in tropical climates.Effects of geometrical and operational parameters on ... A new evaporative cooling system based on the action of centrifugal forces is proposed.Such systems are suitable for cooling large air volumes in tropical climates.Effects of geometrical and operational parameters on system performance are optimized using Taguchi method.It is observed that disc speed,air flow rate and water flow rate are found to have major influence on system performance and other parameter,viz.,disc diameter,pin geometry,evaporation chamber length and orientation of pin have less influence. 展开更多
关键词 HUMIDIFIER Evaporative air cooler Centrifugal force Taguchi method
原文传递
Research trend of cascade heat pumps 被引量:6
6
作者 BOAHEN Samuel CHOI JongMin 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2017年第11期1597-1615,共19页
Most commercial and industrial facilities require very low temperatures for refrigeration and high temperatures for space heating and hot water purposes. Single stage heat pumps have not been able to meet these temper... Most commercial and industrial facilities require very low temperatures for refrigeration and high temperatures for space heating and hot water purposes. Single stage heat pumps have not been able to meet these temperature demands and have been characterized by low capacities and coefficient of performance(COP). Cascade heat pump has been developed to overcome the weaknesses of single stage heat pumps. This study reviews recent works done by researchers on cascade heat pumps for refrigeration, heating and hot water generation. Selection of suitable refrigerants to meet the pressure and temperature demands of each stage of the cascade heat pump has been discussed. Optimization of design parameters such as intermediate temperature(low stage condensing and high stage evaporating temperatures), and temperature difference in the cascade heat exchanger for optimum performance of the cascade heat pump has been reviewed. It was found that optimising each design parameter of the cascade heat pump is necessary for maximum system performance and this may improve the exergetic efficiency, especially of cascade refrigeration systems, by about 30.88%. Cascade heat pumps have wider range of application especially for artificial snow production, in the supermarkets,for natural gas liquefaction, in drying clothes and food and as heat recovery system. The performance of cascade heat pumps can be improved by 19% when coupled with other renewable energy sources for various real time applications. Also, there is the need for much research on refrigerant charge amount of cascade heat pumps, refrigerant-refrigerant heat exchangers to be used as cascade heat exchanger, cascade heat pumps for simultaneous cooling, heating and hot water generation and on the use of variable speed compressors and their control strategies in matching system capacity especially at part load conditions. 展开更多
关键词 cascade heat pump low stage high stage OPTIMIZATION system performance REFRIGERANT
原文传递
Thermo-flow characteristics and air flow field leading of the air-cooled condenser cell in a power plant 被引量:8
7
作者 ZHANG WanXi YANG LiJun +1 位作者 DU XiaoZe YANG YongPing 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第9期2475-2482,共8页
Special A-frame geometry of the air-cooled condenser cell and the complicated flow field at the exit of the axial flow fan bring on the air mal-distribution on the surface of the finned tube bundles and the deteriorat... Special A-frame geometry of the air-cooled condenser cell and the complicated flow field at the exit of the axial flow fan bring on the air mal-distribution on the surface of the finned tube bundles and the deteriorated thermo-flow performances of a condenser cell. It is of benefit to the design and operation optimization of the direct dry cooling system in a power plant to investigate the thermo-flow characteristics of the condenser cell and propose the flow leading measures of cooling air. On the basis of the representative configuration of the air-cooled condenser cell in a 600 MW direct dry cooling power plant, the computa- tional models of the air side fluid and heat flows are built, in which the actual fan blade geometric details are considered. Various flow field leading ways of cooling air are presented and the thermo-flow characteristics in the A-frame condenser cell and through the finned tube bundles are compared. Results show that the flow field leading measures can result in the increased volumetric flow rate and heat rejection, thus bringing on the improved performance of the condenser cell. The improvement of thermo-flow oerformances depends upon the geometric details of the flow guiding device. 展开更多
关键词 air-cooled condenser axial flow fan t'mned tube bundle flow and heat transfer characteristics flow field leading
原文传递
Research on Cooling Effect with Coolant Groove Structure Parameters in Platelet Transpiration Cooled Nosetip
8
作者 RONG Yisheng and LIU Weiqiang College of Aerospace and Material Engineering,National Univ.of Defense Technology,Changsha 410073,China 《Journal of Thermal Science》 SCIE EI CAS CSCD 2010年第5期438-444,共7页
A platelet transpiration cooled nosetip is considered as thermal protection system (TPS) to prevent hypersonic ve- hicle from the serious aerodynamic heating. Based on the one dimensional flow model, a distribution ... A platelet transpiration cooled nosetip is considered as thermal protection system (TPS) to prevent hypersonic ve- hicle from the serious aerodynamic heating. Based on the one dimensional flow model, a distribution model of coolant is proposed for the temperature calculation. When Si = Sj (i, j=1,… 24), the first cooling effect parameter Pmax is proposed and its relationship with total mass flux and Sc0/Si is investigated. The result shows that Pmax increases while the total mass flux increases, and when the mass flux is fixed, Pmax increases rapidly at the be- ginning and then turns to a nearly stable value while Sc0/Si increases. Then under the precondition of cooling ef- fect, we fix Sc0/Si to insure there is enough space for the pipe. Numerical investigation shows the design of the nosetip makes the transpiration cooling extremely effective. In order to reduce the temperature difference on the nosetip, the second cooling effect parameter Pdiff is proposed and different Pdiff with different 0gi (i=1,..., 23) are analyzed. According to the cases we design, Pdiff decreases while the upstream 0gi decreases or the down- stream 0gi increases. The best result among cases shows Pdiff is reduced by 15.1%. 展开更多
关键词 PLATELET transpiration cooling nosetip thermal protection system aerodynamic heating
原文传递
Research on Cooling Effectiveness in Stepped Slot Film Cooling Vane
9
作者 LI Yulong WU Hong +1 位作者 ZHOU Feng RONG Chengjun 《Journal of Thermal Science》 SCIE EI CAS CSCD 2016年第3期273-279,共7页
As one of the most important developments in air cooling technology for hot parts of the aero-engine, film cool- ing technology has been widely used. Film cooling hole structure exists mainly in areas that have high t... As one of the most important developments in air cooling technology for hot parts of the aero-engine, film cool- ing technology has been widely used. Film cooling hole structure exists mainly in areas that have high temperature, uneven cooling effectiveness issues when in actual use. The first stage turbine vanes of the aero-engine consume the largest portion of cooling air, thereby the research on reducing the amount of cooling air has the greatest potential. A new stopped slot film cooling vane with a high cooling effectiveness and a high cooling uniformity was researched initially. Through numerical methods, the affecting factors of the cooling effectiveness of a vane with the stepped slot film cooling structure were researched. This paper focuses on the cooling effectiveness and the pressure loss in different blowing ratio conditions, then the most reasonable and scientific structure parameter can be obtained by analyzing the results. The results show that 1.0 mm is the optimum slot width and 10.0 is the most reasonable blowing ratio. Under this condition, the vane achieved the best cooling result and the highest cooling effectiveness, and also retained a low pressure loss. 展开更多
关键词 Film cooling Cooling effectiveness Blowing ratio Pressure loss
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部