期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
逆流式冷却器的结构分析 被引量:5
1
作者 王进红 周玉姣 《粮食与饲料工业》 CAS 北大核心 2011年第10期39-41,共3页
逆流式冷却器是现代颗粒饲料生产工艺中冷却系统的关键设备。它直接影响颗粒饲料的降温除湿效果和产品的质量指标。介绍了逆流式冷却器的冷却原理,并分析了重要结构部件散料器、排料机构等的工作原理和特点,在生产实践和理论分析的基础... 逆流式冷却器是现代颗粒饲料生产工艺中冷却系统的关键设备。它直接影响颗粒饲料的降温除湿效果和产品的质量指标。介绍了逆流式冷却器的冷却原理,并分析了重要结构部件散料器、排料机构等的工作原理和特点,在生产实践和理论分析的基础上,为合理选择和正确使用逆流式冷却器提供参考。 展开更多
关键词 颗粒饲料 逆流式冷却 喂料器 散料器 冷却仓 排料机构
下载PDF
Influence of Cooling Systems on the Behaviour of Dairy Cows Housed in Cubicle Barn
2
作者 Matteo Barbari Lorenzo Leso Giuseppe Rossi Alberto Scaramelli Stefano Simonini 《Journal of Agricultural Science and Technology(A)》 2012年第1期40-49,共10页
The aim of this paper is to collect information about dairy cow's behaviour connected to different environmental conditions. During summer 2009 and winter 2010 experimental trials were arranged to verify the behaviou... The aim of this paper is to collect information about dairy cow's behaviour connected to different environmental conditions. During summer 2009 and winter 2010 experimental trials were arranged to verify the behaviour of dairy cows in a farm located in Po Plain (Italy). The barn was provided with an air-water cooling system, based on the use of fans and sprinklers placed only in the feeding alley. Two different trials were carried out. The first experiment was targeted on verifying the use of the cubicles by the cows in relation to the availability of the cooling system only in feeding area. The second trial aimed at testing the effectiveness of zone cooling systems placed in the front of cubicles. For this purpose three cubicles in the barn were provided with cooling systems, based on the input of high velocity conditioned air streams. The results clearly remark that the behaviour of the animals is greatly influenced by the environmental conditions. With high temperatures the use of the cubicles is deeply reduced and the animals prefer to stay in feeding area, thus benefiting from the cooling effect of water sprinkled by the showers and of the air streams created by the fans. With air temperatures increasing from 21℃ to 33 ℃ the cows reduce the staying in the cubicles, which gets down from 540 to 32% (r2 = 0.2608). As regards the efficacy of zone cooling system in the cubicles, the results are not particularly encouraging. The cows continue to use the cubicles without changing the behaviour in relation to the presence of conditioned air flow. 展开更多
关键词 Dairy cows BEHAVIOUR microclimatic conditions cooling systems cubicles
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部