The metastable liquid phase separation and rapid solidification behaviours of Co61.8Cu38.2 alloy were investigated by using differential thermal analysis (DTA) in combination with glass fluxing, electromagnetic levi...The metastable liquid phase separation and rapid solidification behaviours of Co61.8Cu38.2 alloy were investigated by using differential thermal analysis (DTA) in combination with glass fluxing, electromagnetic levitation (EML) and drop tube techniques. It is found that the liquid phase separation process and the solidification microstructures intensively depend on the experimental processing parameters, such as undercooling level, cooling rate, gravity level, liquid surface tension and the wetting state of crucible. Large undercooling and surface tension difference of the two liquids tend to facilitate further separation and cause severe macrosegregation. On the other hand, rapid cooling and low gravity effectively suppress the coalescence of the minority phase, Severe maerosegregation patterns are formed in the bulk samples processed by both DTA and EML. In contrast, disperse structures with fine spherical Cu-rich spheres homogeneously distributed in the matrix of Co-rich phase have been obtained in drop tube.展开更多
In order to assess the influences of curved hole passage on cooling effectiveness and flow structure of turbine blade leading edge,the detached eddy simulation is applied to numerically investigate the AGTB turbine ca...In order to assess the influences of curved hole passage on cooling effectiveness and flow structure of turbine blade leading edge,the detached eddy simulation is applied to numerically investigate the AGTB turbine cascade under the condition of global blowing ratio M=0.7.The straight or curved cooling holes are located at either the pressure or suction side near the leading edge.The analysis and discussion focus on the local turbulence structure;influence of pressure gradient on the structure,and distribution of cooling effectiveness on the blade surface.The numerical results show that cooling hole with curved passage could bring positive impact on the increase of the local cooling effectiveness.On the suction side,the increased cooling effectiveness could be about 82% and about 77% on the pressure side,compared to the conventional straight hole.展开更多
In order to resolve the problems of the current air separation process such as the complex process, cumbersome operation and high operating costs, a novel air separation process cooled by LNG cold energy is proposed i...In order to resolve the problems of the current air separation process such as the complex process, cumbersome operation and high operating costs, a novel air separation process cooled by LNG cold energy is proposed in this paper, which is based on high-efficiency heat exchanger network and chemical packing separation technology. The operating temperature range of LNG cold energy is widened from 133K-203K to l13K-283K by high- efficiency heat exchanger network and air separation pressure is declined from 0.5MPa to about 0.35MPa due to packing separation technology, thereby greatly improve the energy efficiency. Both the traditional and novel air separation processes are simulated with air handling capacity of 20t'h-1. Comparing with the traditional process, the LNG consumption is reduced by 44.2%, power consumption decrease is 211.5 kWh per hour, which means the annual benefit will be up to 1.218 million CNY. And the exergy efficiency is also improved by 42.5%.展开更多
The heat generation model and three-dimensional computational fluid dynamics model for lithium ion cells were established with boundary conditions defined.In order to provide a better insight about the behaviors of hi...The heat generation model and three-dimensional computational fluid dynamics model for lithium ion cells were established with boundary conditions defined.In order to provide a better insight about the behaviors of high-power lithium ion cells under realistic discharge conditions,the temperature difference of the cells and an active thermal management system with a pure air-cooling mode were analyzed and predicted with the factors affecting the unevenness of temperature field discussed.The results show a significant effect of the cooling flow rate on the temperature rise of the cells for all discharge rates.Average surface temperatures are relatively uniform at lower discharge rate that makes it easier to control the temperature of the pack.Cell temperatures are expected to rise significantly toward the end of discharge and they show non-uniformity at higher discharge rates.Adequate air flow rate of active cooling is required at high discharge rate and high ambient temperature for practical pack thermal management system.展开更多
文摘The metastable liquid phase separation and rapid solidification behaviours of Co61.8Cu38.2 alloy were investigated by using differential thermal analysis (DTA) in combination with glass fluxing, electromagnetic levitation (EML) and drop tube techniques. It is found that the liquid phase separation process and the solidification microstructures intensively depend on the experimental processing parameters, such as undercooling level, cooling rate, gravity level, liquid surface tension and the wetting state of crucible. Large undercooling and surface tension difference of the two liquids tend to facilitate further separation and cause severe macrosegregation. On the other hand, rapid cooling and low gravity effectively suppress the coalescence of the minority phase, Severe maerosegregation patterns are formed in the bulk samples processed by both DTA and EML. In contrast, disperse structures with fine spherical Cu-rich spheres homogeneously distributed in the matrix of Co-rich phase have been obtained in drop tube.
基金supported by the National Natural Science Foundation of China (Grant No. 50876028)
文摘In order to assess the influences of curved hole passage on cooling effectiveness and flow structure of turbine blade leading edge,the detached eddy simulation is applied to numerically investigate the AGTB turbine cascade under the condition of global blowing ratio M=0.7.The straight or curved cooling holes are located at either the pressure or suction side near the leading edge.The analysis and discussion focus on the local turbulence structure;influence of pressure gradient on the structure,and distribution of cooling effectiveness on the blade surface.The numerical results show that cooling hole with curved passage could bring positive impact on the increase of the local cooling effectiveness.On the suction side,the increased cooling effectiveness could be about 82% and about 77% on the pressure side,compared to the conventional straight hole.
文摘In order to resolve the problems of the current air separation process such as the complex process, cumbersome operation and high operating costs, a novel air separation process cooled by LNG cold energy is proposed in this paper, which is based on high-efficiency heat exchanger network and chemical packing separation technology. The operating temperature range of LNG cold energy is widened from 133K-203K to l13K-283K by high- efficiency heat exchanger network and air separation pressure is declined from 0.5MPa to about 0.35MPa due to packing separation technology, thereby greatly improve the energy efficiency. Both the traditional and novel air separation processes are simulated with air handling capacity of 20t'h-1. Comparing with the traditional process, the LNG consumption is reduced by 44.2%, power consumption decrease is 211.5 kWh per hour, which means the annual benefit will be up to 1.218 million CNY. And the exergy efficiency is also improved by 42.5%.
基金supported by the National Natural Science Foundation of China(No.50976011)the Fundamental Research Funds for the Central Universities(No.2009JBM090)
文摘The heat generation model and three-dimensional computational fluid dynamics model for lithium ion cells were established with boundary conditions defined.In order to provide a better insight about the behaviors of high-power lithium ion cells under realistic discharge conditions,the temperature difference of the cells and an active thermal management system with a pure air-cooling mode were analyzed and predicted with the factors affecting the unevenness of temperature field discussed.The results show a significant effect of the cooling flow rate on the temperature rise of the cells for all discharge rates.Average surface temperatures are relatively uniform at lower discharge rate that makes it easier to control the temperature of the pack.Cell temperatures are expected to rise significantly toward the end of discharge and they show non-uniformity at higher discharge rates.Adequate air flow rate of active cooling is required at high discharge rate and high ambient temperature for practical pack thermal management system.