Studies on the self-leveling behavior of debris bed are crucial for the assessment of core-disruptive accident (CDA) occurred in sodium-cooled fast reactors (SFR). To clarify this behavior over a comparatively wider r...Studies on the self-leveling behavior of debris bed are crucial for the assessment of core-disruptive accident (CDA) occurred in sodium-cooled fast reactors (SFR). To clarify this behavior over a comparatively wider range of gas velocities, a series of experiments were performed by injecting nitrogen gas uniformly from a pool bottom. Current experiments were conducted in a cylindrical tank, in which water, nitrogen gas and different kinds of solid particles, simulate the coolant, vapor (generated by coolant boiling) and fuel debris, respectively. Based on the quantitative data obtained (mainly the time variation of bed inclination angle), with the help of dimensional analysis technique, a set of empirical correlations to predict the self-leveling development depending on particle size, particle density and gas injection velocity was proposed and discussed. It was seen that good agreement could be obtained between the calculated and experimental values. Rationality of the correlations was further confirmed through detailed analyses of the effects of experimental parameters such as particle size, particle density, gas flow rate and boiling mode. In order to facilitate future analyses and simulations of CDAs in SFRs, the obtained results in this work will be utilized for the validations of an advanced fast reactor safety analysis code.展开更多
This study constructed a mathematic model of a variable frequency centrifugal chiller using Simulink software. By running the simulation, it was discovered that when the other factors are constant, the EER(Energy Effi...This study constructed a mathematic model of a variable frequency centrifugal chiller using Simulink software. By running the simulation, it was discovered that when the other factors are constant, the EER(Energy Efficiency Ratio) of the chiller increases with decreases in the temperature of the cooling water and increases in the temperature of the chilled water. The effect of changes in the cooling water temperature on the EER of the chiller is stronger than that of changes in the chilled water temperature. In addition, as the chiller load decreases, the EER increases until reaching a maximum, after which it decreases. Furthermore, the EER of chillers working under a constant flow rate is slightly higher than that of those working under varying flow rates.展开更多
A grate cooler is key equipment in quenching clinker and recovering heat in cement production. A two-dimensional numerical model based on a 5000 t/d cement plant is proposed to for a study on the gas-solid coupled hea...A grate cooler is key equipment in quenching clinker and recovering heat in cement production. A two-dimensional numerical model based on a 5000 t/d cement plant is proposed to for a study on the gas-solid coupled heat transfer process between the cooling air and clinker in a grate cooler. In this study, we use the Fluent dynamic mesh technique and porous media model through which the transient temperature distribution with the clinker motion process and steady temperature and pressure distribution are obtained. We validate the numerical model with the operating data of the cooling air outlet temperature. Then, we discuss the amount of mid-temperature air outlet and average diameter of clinker particles, which affect the heat effective utilization and cooling air pressure drop in clinker layer. We found that after adding one more mid-temperature air outlet, the average temperature of the air flowing into the heat recovery boiler increases by 29.04℃ and the ratio of heat effective utilization increases by 5.3%. This means heat recovery is more effective on adding one more mid-temperature air outlet. Further, the smaller the clinker particles, the more is the pressure drop in clinker layer; thus more power consumption is needed by the cooling fan.展开更多
基金Supported by an annual joint research project between Japan Atomic Energy Agency (JAEA) and Kyushu University
文摘Studies on the self-leveling behavior of debris bed are crucial for the assessment of core-disruptive accident (CDA) occurred in sodium-cooled fast reactors (SFR). To clarify this behavior over a comparatively wider range of gas velocities, a series of experiments were performed by injecting nitrogen gas uniformly from a pool bottom. Current experiments were conducted in a cylindrical tank, in which water, nitrogen gas and different kinds of solid particles, simulate the coolant, vapor (generated by coolant boiling) and fuel debris, respectively. Based on the quantitative data obtained (mainly the time variation of bed inclination angle), with the help of dimensional analysis technique, a set of empirical correlations to predict the self-leveling development depending on particle size, particle density and gas injection velocity was proposed and discussed. It was seen that good agreement could be obtained between the calculated and experimental values. Rationality of the correlations was further confirmed through detailed analyses of the effects of experimental parameters such as particle size, particle density, gas flow rate and boiling mode. In order to facilitate future analyses and simulations of CDAs in SFRs, the obtained results in this work will be utilized for the validations of an advanced fast reactor safety analysis code.
基金supported by a Grant-in-Aid for Scientific Research through grant number KM200610016003 from the Beijing Municipal Commission of Education
文摘This study constructed a mathematic model of a variable frequency centrifugal chiller using Simulink software. By running the simulation, it was discovered that when the other factors are constant, the EER(Energy Efficiency Ratio) of the chiller increases with decreases in the temperature of the cooling water and increases in the temperature of the chilled water. The effect of changes in the cooling water temperature on the EER of the chiller is stronger than that of changes in the chilled water temperature. In addition, as the chiller load decreases, the EER increases until reaching a maximum, after which it decreases. Furthermore, the EER of chillers working under a constant flow rate is slightly higher than that of those working under varying flow rates.
基金supported by the Horizontal Subject(Grant No.11471501)the National Basic Research Program of China("973"Project)(Grant No.2013CB228305)
文摘A grate cooler is key equipment in quenching clinker and recovering heat in cement production. A two-dimensional numerical model based on a 5000 t/d cement plant is proposed to for a study on the gas-solid coupled heat transfer process between the cooling air and clinker in a grate cooler. In this study, we use the Fluent dynamic mesh technique and porous media model through which the transient temperature distribution with the clinker motion process and steady temperature and pressure distribution are obtained. We validate the numerical model with the operating data of the cooling air outlet temperature. Then, we discuss the amount of mid-temperature air outlet and average diameter of clinker particles, which affect the heat effective utilization and cooling air pressure drop in clinker layer. We found that after adding one more mid-temperature air outlet, the average temperature of the air flowing into the heat recovery boiler increases by 29.04℃ and the ratio of heat effective utilization increases by 5.3%. This means heat recovery is more effective on adding one more mid-temperature air outlet. Further, the smaller the clinker particles, the more is the pressure drop in clinker layer; thus more power consumption is needed by the cooling fan.