讨论空压机冷却水软化前后对空压机运行的影响 被引量:1
1
作者 黄小强 《江西化工》 2019年第6期96-98,共3页
随着当前工矿行业的飞速发展,空压机的应用也就随之大幅增加,而空压机的运行效率受很多因素的影响,其中空压机冷却水软化对于空压机的影响就是其中一方面,恰恰工作人员最容易忽视的就是对空压机冷却水进行软化,应当采取措施加强工作人... 随着当前工矿行业的飞速发展,空压机的应用也就随之大幅增加,而空压机的运行效率受很多因素的影响,其中空压机冷却水软化对于空压机的影响就是其中一方面,恰恰工作人员最容易忽视的就是对空压机冷却水进行软化,应当采取措施加强工作人员对于空压机冷却水软化重要性观念的培养,据此,本文将主要围绕空压机啊冷却水软化前后对空压机运行的影响进行分析讨论[1]. 展开更多
关键词 空压机冷却水软化 空压机运行 影响讨论
下载PDF
水平连铸结晶器冷却水系统软化改造 被引量:1
2
作者 钟春生 《湖南冶金》 2003年第2期43-44,共2页
介绍了水平连铸结晶器冷却水系统的改造措施 ,新系统的工作原理 。
关键词 水平连铸 结晶器 冷却水软化
下载PDF
Optimum control strategy for all-variable speed chiller plant 被引量:3
3
作者 蒋小强 龙惟定 李敏 《Journal of Central South University》 SCIE EI CAS 2011年第2期573-579,共7页
The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation ... The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation model of water source chiller plant established in dynamic transient simulation program (TRNSYS),the four-variable quadratic orthogonal regression experiments were carried out by taking cooling load,cooling water supply temperature,cooling water flow rate and chilled water flow rate as variables,and the fitting formulas expressing the relationships between the total energy consumption of chiller plant with the four selected parameters was obtained. With the SAS statistical software and MATHEMATICA mathematical software,the optimal chilled water flow rate and cooling water flow rate which result in the minimum total energy consumption were determined under continuously varying cooling load and cooling water supply temperature. With regard to a chiller plant serving an office building in Shanghai,the total energy consumptions under different control strategies were computed in terms of the forecasting function of cooling load and water source temperature. The results show that applying the optimal control strategy to the chiller plant can bring a saving of 23.27% in power compared with the corresponding conventional variable speed plant,indicating that the optimal control strategy can improve the energy efficiency of chiller plant. 展开更多
关键词 chiller plant control strategy variable speed cooling water flow rate chilled water flow rate
下载PDF