A chilling-repressed cDNA fragment was cloned from rice ( Oryza sativa L.) seedlings by reverse transcription-polymerase chain reaction (RT-PCR) differential display. Database comparison of the cDNA sequence is identi...A chilling-repressed cDNA fragment was cloned from rice ( Oryza sativa L.) seedlings by reverse transcription-polymerase chain reaction (RT-PCR) differential display. Database comparison of the cDNA sequence is identical to atpH encoded by rice chloroplast genome. Northern hybridization showed that its RNA transcript was reduced greatly on the first day and fully inhibited after 2 d of chilling treatment.展开更多
An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of t...An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of the cooler is experimentally examined. Two parallelplaced needle valves with an opposite flow direction called as double-valved configuration, instead of conventional single-valved configuration as the double-inlet is used to reduce the DC flow. With the double-valved configuration, the minimum temperatures of 18.4 K and 14.7 K, and the cooling powers of 11.5 W and 29.5 W are also obtained by RW2 and CP4000, respectively.展开更多
文摘A chilling-repressed cDNA fragment was cloned from rice ( Oryza sativa L.) seedlings by reverse transcription-polymerase chain reaction (RT-PCR) differential display. Database comparison of the cDNA sequence is identical to atpH encoded by rice chloroplast genome. Northern hybridization showed that its RNA transcript was reduced greatly on the first day and fully inhibited after 2 d of chilling treatment.
文摘An experimental investigation on DC flow suppression in a single-stage G-M type pulse tube cooler is made. The influence of DC flow induced by the introduction of the double-inlet on the refrigeration performance of the cooler is experimentally examined. Two parallelplaced needle valves with an opposite flow direction called as double-valved configuration, instead of conventional single-valved configuration as the double-inlet is used to reduce the DC flow. With the double-valved configuration, the minimum temperatures of 18.4 K and 14.7 K, and the cooling powers of 11.5 W and 29.5 W are also obtained by RW2 and CP4000, respectively.