A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building...A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building: Xijindu exhibition hall, which is located in Zhenjiang city in China. Numerical studies on the thermal comfort and energy consumption of the system are carded out by using TRNSYS software. The results indicate that the system with the radiant floor method or the radiant ceiling method shows good thermal comfort without mechanical ventilation in winter. However, the system with either of the methods should add mechanical ventilation to ensure good comfort in summer. At the same level of thermal comfort, it can also be found that the annual energy consumption of the radiant ceiling system is less than that of the radiant floor system.展开更多
In Turkey, most of the common type projects of mass production residential buildings are being developed and constructed by TOK1 (Housing Development Administration of Turkey). These buildings, in which energy effic...In Turkey, most of the common type projects of mass production residential buildings are being developed and constructed by TOK1 (Housing Development Administration of Turkey). These buildings, in which energy efficient approach has been disregarded for years, cause to gradually increase on heating and cooling energy consumptions. In regards to national economics, it is essential to evaluate energy efficiency and to develop suggestions to decrease energy consumptions in residential buildings. To achieve appropriate solutions, cost evaluation also becomes necessary. Therefore, this paper aims to introduce a study which serves the purpose of producing a choice of energy efficient solutions in order to reduce energy consumptions and energy cost. In this study, different heating and cooling energy efficient scenarios have been developed for a selected residential building, constructed by TOKI, for climatic zones of Turkey. For each scenario, energy simulations have been executed by means of the simulation program--DesignBuilder, the user-friendly visual interface of EnergyPlus, and cost analysis has been carried out by using the net present value and discounted payback period method. As a result, energy and cost effective solutions have been presented and discussed for different climatic zones.展开更多
Preliminary investigation shows that air sourced type heat pumps by energy efficiency are competitive with gas boilers having 93% of coefficient of performance (COP) if heat pumps are used in climatic zones, having ...Preliminary investigation shows that air sourced type heat pumps by energy efficiency are competitive with gas boilers having 93% of coefficient of performance (COP) if heat pumps are used in climatic zones, having outside air temperature higher than (-3 ℃ to -5 ℃). But, in such conditions the heat pump's evaporator is covered by ice crust, which cuts off the flow of outside air-heat source through the evaporator of heat pump. For avoiding stating problems it is recommended to use as heat source a mixture of waste warm gases. In this article a high efficiency heating-cooling system is developed, consisting of warm gases mixture sourced heat pump, heating boiler operating simultaneously with heat pump and solar air heater. The heating demand of the served house is shared between boiler and heat pump. Instead of outside air the warm gases mixture enters into evaporator of heat pump. A new construction of heat exchanger was developed. The article presents the structure and principle of operation, as well as the method for optimization and design of suggested system. Analysis proved high energy efficiency and cost effectiveness of the new system.展开更多
基金The National Natural Science Foundation of China(No. 51036001 )the Natural Science Foundation of Jiangsu Province(No. BK2010043)
文摘A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building: Xijindu exhibition hall, which is located in Zhenjiang city in China. Numerical studies on the thermal comfort and energy consumption of the system are carded out by using TRNSYS software. The results indicate that the system with the radiant floor method or the radiant ceiling method shows good thermal comfort without mechanical ventilation in winter. However, the system with either of the methods should add mechanical ventilation to ensure good comfort in summer. At the same level of thermal comfort, it can also be found that the annual energy consumption of the radiant ceiling system is less than that of the radiant floor system.
文摘In Turkey, most of the common type projects of mass production residential buildings are being developed and constructed by TOK1 (Housing Development Administration of Turkey). These buildings, in which energy efficient approach has been disregarded for years, cause to gradually increase on heating and cooling energy consumptions. In regards to national economics, it is essential to evaluate energy efficiency and to develop suggestions to decrease energy consumptions in residential buildings. To achieve appropriate solutions, cost evaluation also becomes necessary. Therefore, this paper aims to introduce a study which serves the purpose of producing a choice of energy efficient solutions in order to reduce energy consumptions and energy cost. In this study, different heating and cooling energy efficient scenarios have been developed for a selected residential building, constructed by TOKI, for climatic zones of Turkey. For each scenario, energy simulations have been executed by means of the simulation program--DesignBuilder, the user-friendly visual interface of EnergyPlus, and cost analysis has been carried out by using the net present value and discounted payback period method. As a result, energy and cost effective solutions have been presented and discussed for different climatic zones.
文摘Preliminary investigation shows that air sourced type heat pumps by energy efficiency are competitive with gas boilers having 93% of coefficient of performance (COP) if heat pumps are used in climatic zones, having outside air temperature higher than (-3 ℃ to -5 ℃). But, in such conditions the heat pump's evaporator is covered by ice crust, which cuts off the flow of outside air-heat source through the evaporator of heat pump. For avoiding stating problems it is recommended to use as heat source a mixture of waste warm gases. In this article a high efficiency heating-cooling system is developed, consisting of warm gases mixture sourced heat pump, heating boiler operating simultaneously with heat pump and solar air heater. The heating demand of the served house is shared between boiler and heat pump. Instead of outside air the warm gases mixture enters into evaporator of heat pump. A new construction of heat exchanger was developed. The article presents the structure and principle of operation, as well as the method for optimization and design of suggested system. Analysis proved high energy efficiency and cost effectiveness of the new system.