Preliminary investigation shows that air sourced type heat pumps by energy efficiency are competitive with gas boilers having 93% of coefficient of performance (COP) if heat pumps are used in climatic zones, having ...Preliminary investigation shows that air sourced type heat pumps by energy efficiency are competitive with gas boilers having 93% of coefficient of performance (COP) if heat pumps are used in climatic zones, having outside air temperature higher than (-3 ℃ to -5 ℃). But, in such conditions the heat pump's evaporator is covered by ice crust, which cuts off the flow of outside air-heat source through the evaporator of heat pump. For avoiding stating problems it is recommended to use as heat source a mixture of waste warm gases. In this article a high efficiency heating-cooling system is developed, consisting of warm gases mixture sourced heat pump, heating boiler operating simultaneously with heat pump and solar air heater. The heating demand of the served house is shared between boiler and heat pump. Instead of outside air the warm gases mixture enters into evaporator of heat pump. A new construction of heat exchanger was developed. The article presents the structure and principle of operation, as well as the method for optimization and design of suggested system. Analysis proved high energy efficiency and cost effectiveness of the new system.展开更多
Cooling water is an important part in a Spallation Neutron Source target cooling system, but the unstable vortexes at the exits of the slits between every two tungsten target slices have a negative impact on the stabl...Cooling water is an important part in a Spallation Neutron Source target cooling system, but the unstable vortexes at the exits of the slits between every two tungsten target slices have a negative impact on the stable running of the target system. We apply the field synergy principle for fluid flow to obtain the optimal flow field, which has a uniform velocity distribution without eddy, and then, optimize the geometrical structure of the cooling water flow channel based on the optimal flow field. The results show that when the cooling water flows in the optimized channel, the eddy sizes decrease, the time fluctuations of velocity and pressure almost vanish, and the volume flow rates of the cooling water in each parallel slit are uniform. Therefore, it effectively improves the running stability of the target system with the premise of satisfying the target heat load.展开更多
文摘Preliminary investigation shows that air sourced type heat pumps by energy efficiency are competitive with gas boilers having 93% of coefficient of performance (COP) if heat pumps are used in climatic zones, having outside air temperature higher than (-3 ℃ to -5 ℃). But, in such conditions the heat pump's evaporator is covered by ice crust, which cuts off the flow of outside air-heat source through the evaporator of heat pump. For avoiding stating problems it is recommended to use as heat source a mixture of waste warm gases. In this article a high efficiency heating-cooling system is developed, consisting of warm gases mixture sourced heat pump, heating boiler operating simultaneously with heat pump and solar air heater. The heating demand of the served house is shared between boiler and heat pump. Instead of outside air the warm gases mixture enters into evaporator of heat pump. A new construction of heat exchanger was developed. The article presents the structure and principle of operation, as well as the method for optimization and design of suggested system. Analysis proved high energy efficiency and cost effectiveness of the new system.
基金supported by the National Natural Science Foundation of China (Grant Nos. 51006060, 51036003)the Foundation for the Author of National Excellent Doctoral Dissertation of China (Grant No.201150)
文摘Cooling water is an important part in a Spallation Neutron Source target cooling system, but the unstable vortexes at the exits of the slits between every two tungsten target slices have a negative impact on the stable running of the target system. We apply the field synergy principle for fluid flow to obtain the optimal flow field, which has a uniform velocity distribution without eddy, and then, optimize the geometrical structure of the cooling water flow channel based on the optimal flow field. The results show that when the cooling water flows in the optimized channel, the eddy sizes decrease, the time fluctuations of velocity and pressure almost vanish, and the volume flow rates of the cooling water in each parallel slit are uniform. Therefore, it effectively improves the running stability of the target system with the premise of satisfying the target heat load.