Coated wire sensor for potentiometric determination ofDAP (dapoxetine HCI) in pure form and in biological fluidsbased on DAP-TPB (dapoxetine-tetraphenyl borate) as the sensing element in the presence of DOP (dioc...Coated wire sensor for potentiometric determination ofDAP (dapoxetine HCI) in pure form and in biological fluidsbased on DAP-TPB (dapoxetine-tetraphenyl borate) as the sensing element in the presence of DOP (dioctylphthalate) as the plasticizing solvent mediator was prepared. The best performance was obtained with a membrane composition of 10.0% (w/w) ion-pair, 45.0% DOP (w/w) and 45.0% PVC (w/w). The electrode showed a Nemstian response (with a slope of 58.70 mV decade-1) for the concentration range of 4.2 × 10-5-1.0 ×10-2 mol/L. It illustrates a relatively fast response time in the whole concentration range (-15 s) in a pH range of 3.0-7.5. The selectivity coefficients were determined in relation to several inorganic and organic species. DAP is determined successfully in pure solutions and in biological fuids using the standard additions and petentiometric titrations methods.展开更多
This paper provides a method to infer finger flexing motions using a 4-channel surface Electronyogram (sEMG). Surface EMGs are hannless to the humnan body and easily done. However, they do not reflect the activity o...This paper provides a method to infer finger flexing motions using a 4-channel surface Electronyogram (sEMG). Surface EMGs are hannless to the humnan body and easily done. However, they do not reflect the activity of specific nerves or muscles, unlike invasive EMCs. On the other hand, the non-invasive type is difficult to use for discriminating various motions while using only a small number of electrodes. Surface EMG data in this study were obtained from four electodes placed around the forearm. The motions were the flexion of each 5 single fingers (thumb, index finger, middle finger, ring finger, and little fingers). One subject was trained with these motions and another left was untrained. The maximum likelihood estimation method was used to infer the finger motion. Experimental results have showed that this method could be useful for recognizing finger motions.The average accuracy was as high as 95%.展开更多
文摘Coated wire sensor for potentiometric determination ofDAP (dapoxetine HCI) in pure form and in biological fluidsbased on DAP-TPB (dapoxetine-tetraphenyl borate) as the sensing element in the presence of DOP (dioctylphthalate) as the plasticizing solvent mediator was prepared. The best performance was obtained with a membrane composition of 10.0% (w/w) ion-pair, 45.0% DOP (w/w) and 45.0% PVC (w/w). The electrode showed a Nemstian response (with a slope of 58.70 mV decade-1) for the concentration range of 4.2 × 10-5-1.0 ×10-2 mol/L. It illustrates a relatively fast response time in the whole concentration range (-15 s) in a pH range of 3.0-7.5. The selectivity coefficients were determined in relation to several inorganic and organic species. DAP is determined successfully in pure solutions and in biological fuids using the standard additions and petentiometric titrations methods.
基金supported by the The Ministry of Knowledge Economy,Koreaunder the ITRC(Information Technology Research Center)support programsupervised by the ⅡTA(Institute for Information Technology Advancement)ⅡTA-2008-C1090-0803-0006
文摘This paper provides a method to infer finger flexing motions using a 4-channel surface Electronyogram (sEMG). Surface EMGs are hannless to the humnan body and easily done. However, they do not reflect the activity of specific nerves or muscles, unlike invasive EMCs. On the other hand, the non-invasive type is difficult to use for discriminating various motions while using only a small number of electrodes. Surface EMG data in this study were obtained from four electodes placed around the forearm. The motions were the flexion of each 5 single fingers (thumb, index finger, middle finger, ring finger, and little fingers). One subject was trained with these motions and another left was untrained. The maximum likelihood estimation method was used to infer the finger motion. Experimental results have showed that this method could be useful for recognizing finger motions.The average accuracy was as high as 95%.