In the structures whose long-term behavior should be monitored and controlled, creep and shrinkage effects have to be included precisely in the analysis and design procedures. Creep and shrinkage, vary with the consti...In the structures whose long-term behavior should be monitored and controlled, creep and shrinkage effects have to be included precisely in the analysis and design procedures. Creep and shrinkage, vary with the constituent and mixtures proportions, and depend on the curing conditions and work environment as well. Self-compacting concrete (SCC) contains combinations of various components, such as aggregate, cement, superplasticizer, water-reducing agent and other ingredients which affect the properties of the SCC including creep and shrinkage of the SCC. Hence, the realistic prediction creep and shrinkage strains of SCC are an important requirement of the design process of this type of concrete structures. In this study, three proposed creep models and four shrinkage models available in the literature are compared with the measured results of 52 mixtures for creep and 165 mixtures for shrinkage of SCC. The influence of various parameters, such as mixture design, cement content, filler content, aggregate content, and water cement ratio (w/c) on the creep and shrinkage of SCC are also compared and discussed.展开更多
Control of supersonic flow fields with shock wave is important for some industrial fields. There are many studies for control of the supersonic flow fields using active or passive control. When non-equilibrium condens...Control of supersonic flow fields with shock wave is important for some industrial fields. There are many studies for control of the supersonic flow fields using active or passive control. When non-equilibrium condensation occurs in a supersonic flow field, the flow is affected by latent heat released. Many studies for the condensation have been conducted and the characteristics have been almost clarified. Further, it was found that non-equilibrium condensation can control the flow field. In these studies, the condensation occurs across the passage of the flow field and it causes the total pressure loss in the flow field. However, local occurrence of non-equilibrium condensation in the flow field may change the characteristics of total pressure loss compared with that by the condensation across the passage of the nozzle and there are few for researches of locally occurred non-equilibrium condensation in supersonic flow field. The purpose in the present study is to clarify the effect of local occurrence of non-equilibrium condensation on the transonic flow field in a nozzle with a circular bump. As a result, local occurrence of non-equilibrium condensation reduced the shock strength and total pressure loss in the transonic flow field by flowing the moist air from trailing edge of the circular bump to the mainstream.展开更多
文摘In the structures whose long-term behavior should be monitored and controlled, creep and shrinkage effects have to be included precisely in the analysis and design procedures. Creep and shrinkage, vary with the constituent and mixtures proportions, and depend on the curing conditions and work environment as well. Self-compacting concrete (SCC) contains combinations of various components, such as aggregate, cement, superplasticizer, water-reducing agent and other ingredients which affect the properties of the SCC including creep and shrinkage of the SCC. Hence, the realistic prediction creep and shrinkage strains of SCC are an important requirement of the design process of this type of concrete structures. In this study, three proposed creep models and four shrinkage models available in the literature are compared with the measured results of 52 mixtures for creep and 165 mixtures for shrinkage of SCC. The influence of various parameters, such as mixture design, cement content, filler content, aggregate content, and water cement ratio (w/c) on the creep and shrinkage of SCC are also compared and discussed.
文摘Control of supersonic flow fields with shock wave is important for some industrial fields. There are many studies for control of the supersonic flow fields using active or passive control. When non-equilibrium condensation occurs in a supersonic flow field, the flow is affected by latent heat released. Many studies for the condensation have been conducted and the characteristics have been almost clarified. Further, it was found that non-equilibrium condensation can control the flow field. In these studies, the condensation occurs across the passage of the flow field and it causes the total pressure loss in the flow field. However, local occurrence of non-equilibrium condensation in the flow field may change the characteristics of total pressure loss compared with that by the condensation across the passage of the nozzle and there are few for researches of locally occurred non-equilibrium condensation in supersonic flow field. The purpose in the present study is to clarify the effect of local occurrence of non-equilibrium condensation on the transonic flow field in a nozzle with a circular bump. As a result, local occurrence of non-equilibrium condensation reduced the shock strength and total pressure loss in the transonic flow field by flowing the moist air from trailing edge of the circular bump to the mainstream.