期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
简易凝胶柱净化-气相色谱法检测动物源性样品中残留的敌敌畏 被引量:2
1
作者 高洁 郝学慧 朱莉萍 《食品安全质量检测学报》 CAS 2016年第1期356-361,共6页
目的建立动物源样品中敌敌畏的简易凝胶色谱净化-气相色谱检测方法。方法采用凝胶净化粉湿法装填于玻璃层析柱,制成长约15 cm、直径1 cm的简易凝胶净化柱,对样品的净化洗脱液进行分段收集,分析其中敌敌畏回收率的规律。结果最终确定4.6~... 目的建立动物源样品中敌敌畏的简易凝胶色谱净化-气相色谱检测方法。方法采用凝胶净化粉湿法装填于玻璃层析柱,制成长约15 cm、直径1 cm的简易凝胶净化柱,对样品的净化洗脱液进行分段收集,分析其中敌敌畏回收率的规律。结果最终确定4.6~25 m L体积段的洗脱液为敌敌畏的最佳洗脱体积段,乙酸乙酯-环己烷(6:4,V:V)为最优配比的洗脱溶液,凝胶柱装填3.00 g凝胶粉时净化效果最佳。选取猪肉、牛肉、鸡肉、鱼肉样品,进行确证试验,回收率和变异系数均满足精确度要求,方法检出限为0.003μg/m L,加标回收率为88.2%~100.7%,相对标准偏差为0.4%~1.2%。结论该方法快速、灵敏、准确,适合动物源性食品中敌敌畏的测定。 展开更多
关键词 敌敌畏 气相色谱法 凝胶净化柱 动物源样品
下载PDF
The Development of Gel Media and Columns for Large-Scale Chromatography of Proteins, a Historical Review 被引量:2
2
作者 Jan-Christer Janson 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2002年第6期690-695,共6页
The first dedicated protein chromatography media were introduced during the 1950s and 1960s. There was an early awareness of the possibility of using these for production applications within the biopharmaceutical indu... The first dedicated protein chromatography media were introduced during the 1950s and 1960s. There was an early awareness of the possibility of using these for production applications within the biopharmaceutical industry. However, the crucial limitation was the fact that those media that were most compatible with proteins lent themselves less favourably to scaling-up. The problems were primarily physical. Thus the fibrous cellulose media showed bed cracking tendencies and the bead shaped polyacrylamide, dextran, and agarose gel media, then available, were too soft to stand the hydrodynamic forces acting in large columns, leading to bed compaction and increased pressure drop. At the time, the best solution to the latter problem, after a number of intermediary solutions were tried, was the introduction of the stacked column concept in which several short column segments were connected by small bore tubing, thus reducing the force acting on the particles in each bed copartment. However, the ultimate remedy, the introduction of chromatographic matrices that combine the desired features of adequate rigidity, macroporosity, biocompatibility, chemical stability (for CIP and SIP) and derivatizability, did not occur until the middle of the 1980s when adquately cross-linked agarose gel media such as Sepharose Fast Flow were made available. The paper also recognizes the many attempts made during the past 50 years to develop continous chromatography columns. Most of the designs are based on an annular bed or on an array of anularly arranged parallel columns continuously fed with samples in a cyclic manner. The introduction of media and columns for expanded bed adsorption followed a demand for fewer purification steps and shorter process times. In recent years, columns have been introduced that allow packing and repacking without needing to open the column. The review provides an historical account of the developments that have led to the present state-of-the-art both regarding large diameter columns and gel media intended for industrial applications of protein chromatography and also discusses the current trends that point to possible future applications. 展开更多
关键词 CHROMATOGRAPHY PROTEIN review
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部