The evolution of a molecular system excited above its ionization threshold depends on a number of parameters that include the nature of the excited states and their couplings to the various continua. The general natur...The evolution of a molecular system excited above its ionization threshold depends on a number of parameters that include the nature of the excited states and their couplings to the various continua. The general nature of the processes governing this evolution depends also essentially on the complexity of the molecule, more precisely on its size, density of states, and strength of the couplings among the various internal degrees of freedom. In this paper we address the question of the transition between autoionization that prevails in small molecules, and delayed ionization occurring in larger molecules or clusters. This transition is illustrated by autoionization of Na2 Rydberg states on one hand, delayed ionization in fullerene C60, and delayed detachment in small cluster anions on the other hand. All processes are studied in the case of nanosecond laser excitation, corresponding to a rather slow deposition of the internal energy.展开更多
Objective To describe the pitfalls in positron emission tomography/computed tomography (PET/CT) imaging and classify them according to the principles of their generation. Methods We summarized retrospectively the ^...Objective To describe the pitfalls in positron emission tomography/computed tomography (PET/CT) imaging and classify them according to the principles of their generation. Methods We summarized retrospectively the ^18F-fluorodeoxyglucose (FDP) PET/CT imaging pitfalls through reviewing the PET/CT images of 872 patients. The pitfalls were divided into artifacts and infrequent physiological uptake, and the artifacts were further classified according to their causes. Meanwhile, we calculated the incidences of various pitfalls. Whether the PET/CT pitfalls influenced the diagnostic decision was analyzed. The appearances of pitfalls in PET were also described. Results Pitfalls could be found in PET/CT images of 684(78.4%) patients. Artifacts were found in 664 (76.15%) patients, and could be classified into self-factor artifacts and equipment-or technology-related artifacts. Among self-factor artifacts, respiratory motion (57.5%), postprandial or hyperglycemia artifacts (2.41%), and metal or high density matter artifacts (1.38%) were frequent. As for equipment-or tectmology-related factors, injection point outleakage or radiotracer contamination (13.88%) and truncation artifacts (1.83%) were most common ones. Infrequent physiological FDG uptakes, including fatty up-take, endometrial uptake, and bilateral breast feeding period uptake, were found in 20 (2.29%) patients. Among all pitfalls, the artifacts in 92 (13.4%) patients and infrequent physiological uptakes in 6 (0.88%) patients affected the diagnostic results. Artifact images in PET could be described as hot or cold area and the images of infrequent physiological uptake were always shown as hot area. Conclusions The incidence of pitfall in PET/CT imaging was high and the causes of pitfalls are various. Among all causes that artifacts generated, respiratory motion is the most common. Some pitfalls may disturb clinical physicians' decision, so it is important to recognize artifacts and physiological uptake, and distinguish them from pathological uptakes.展开更多
Based on the light nucleus reaction model (Nucl. Sci. Eng. 133 (1999) 218), four aspects (neutron incident energy region, reaction channel analysis, the renewed level schemes and the optical model parameters) o...Based on the light nucleus reaction model (Nucl. Sci. Eng. 133 (1999) 218), four aspects (neutron incident energy region, reaction channel analysis, the renewed level schemes and the optical model parameters) of n+ ^12 C reaction are improved to calculate total outgoing neutron double-dilferential cross sections with modified LUNF code below 30 MeV. The calculated results agree fairly well with the experimental data at En = 14.1 MeV and 18 MeV. The analysis shows that the pre-equilibrium mechanism, which is exactly considered the conservation of energy, momentum and parity, dominates the whole reaction process. The contribution of the neutron emission from 5He to total energy- angular spectra is also considered properly. This modified LUNF code will be a useful tool to set up the file of neutron double-differential crass sections below 30 Me V in the neutron evaluation nuclear data library.展开更多
A subspace-based blind Signal-to-Noise Ratio (SNR) estimation algorithm for digital bandpass signals in Additive White Gaussian Noise (AWGN) channel is discussed. The lower bounds of the mean and variance of the estim...A subspace-based blind Signal-to-Noise Ratio (SNR) estimation algorithm for digital bandpass signals in Additive White Gaussian Noise (AWGN) channel is discussed. The lower bounds of the mean and variance of the estimation are derived, and simulations are performed for the commonly used digital bandpass signals, such as MPSK (M=2, 4, 8), MFSK (M=2, 4) and MQAM (M=16, 64, 128, 256) signals. Theoretical analyses and simulation results indicate that the proposed algorithm is ef- fective even when the SNR is below 0dB. Furthermore, the algorithm can provide a blind estimator in that it needs neither the parameters of the received signals, such as the carrier frequency, symbol rate and modulation scheme, nor the synchronization of the system.展开更多
The reaction dynamics of the fluorine atom with vibrationally excited D2(v=1, v=0) was investigated using the crossed beam method. The scheme of stimulated Raman pumping was employed for preparation of vibrationally e...The reaction dynamics of the fluorine atom with vibrationally excited D2(v=1, v=0) was investigated using the crossed beam method. The scheme of stimulated Raman pumping was employed for preparation of vibrationally excited D2 molecules. Contribution from the reaction of spin-orbit excited F*(2P1/2) with vibrationally excited D2 was not found. Reaction of spin-orbit ground F(2P3/2) with vibrationally excited D2 was measured and DF products populated in v'=2, 3, 4, 5 were observed. Compared with the vibrationally ground reaction, DF products from the vibrationally excited reaction of F(2P3/2)+D2(v=1, j=0) are rotationally “hotter”. Differential cross sections at four collision energies, ranging from 0.32 kcal/mol to 2.62 kcal/mol, were obtained. Backward scattering dominates for DF products in all vibrational levels at the lowest collision energy of 0.32 kcal/mol. As the collision energy increases, angular distribution of DF products gradually shifts from backward to sideway. The collision-energy dependence of differential cross section of DF(v’=5) at forward direction was also measured. Forward-scattered signal of DF(v'=5) appears at the collision energy of 1.0 kcal/mol, and becomes dominated at 2.62 kcal/mol.展开更多
The diagnostic potential of brain positron emission tomography (PET) imaging is limited by low spatial resolution. For solving this problem we propose a technique for the fusion of PET and MRI images. This fusion is...The diagnostic potential of brain positron emission tomography (PET) imaging is limited by low spatial resolution. For solving this problem we propose a technique for the fusion of PET and MRI images. This fusion is a trade-off between the spectral information extracted from PET images and the spatial information extracted from high spatial resolution MRI. The proposed method can control this trade-off. To achieve this goal, it is necessary to build a multiscale fusion model, based on the retinal cell photoreceptors model. This paper introduces general prospects of this model, and its application in multispectral medical image fusion. Results showed that the proposed method preserves more spectral features with less spatial distortion. Comparing with hue-intensity-saturation (HIS), discrete wavelet transform (DWT), wavelet-based sharpening and wavelet-a trous transform methods, the best spectral and spatial quality is only achieved simultaneously with the proposed feature-based data fusion method. This method does not require resampling images, which is an advantage over the other methods, and can perform in any aspect ratio between the pixels of MRI and PET images.展开更多
文摘The evolution of a molecular system excited above its ionization threshold depends on a number of parameters that include the nature of the excited states and their couplings to the various continua. The general nature of the processes governing this evolution depends also essentially on the complexity of the molecule, more precisely on its size, density of states, and strength of the couplings among the various internal degrees of freedom. In this paper we address the question of the transition between autoionization that prevails in small molecules, and delayed ionization occurring in larger molecules or clusters. This transition is illustrated by autoionization of Na2 Rydberg states on one hand, delayed ionization in fullerene C60, and delayed detachment in small cluster anions on the other hand. All processes are studied in the case of nanosecond laser excitation, corresponding to a rather slow deposition of the internal energy.
文摘Objective To describe the pitfalls in positron emission tomography/computed tomography (PET/CT) imaging and classify them according to the principles of their generation. Methods We summarized retrospectively the ^18F-fluorodeoxyglucose (FDP) PET/CT imaging pitfalls through reviewing the PET/CT images of 872 patients. The pitfalls were divided into artifacts and infrequent physiological uptake, and the artifacts were further classified according to their causes. Meanwhile, we calculated the incidences of various pitfalls. Whether the PET/CT pitfalls influenced the diagnostic decision was analyzed. The appearances of pitfalls in PET were also described. Results Pitfalls could be found in PET/CT images of 684(78.4%) patients. Artifacts were found in 664 (76.15%) patients, and could be classified into self-factor artifacts and equipment-or technology-related artifacts. Among self-factor artifacts, respiratory motion (57.5%), postprandial or hyperglycemia artifacts (2.41%), and metal or high density matter artifacts (1.38%) were frequent. As for equipment-or tectmology-related factors, injection point outleakage or radiotracer contamination (13.88%) and truncation artifacts (1.83%) were most common ones. Infrequent physiological FDG uptakes, including fatty up-take, endometrial uptake, and bilateral breast feeding period uptake, were found in 20 (2.29%) patients. Among all pitfalls, the artifacts in 92 (13.4%) patients and infrequent physiological uptakes in 6 (0.88%) patients affected the diagnostic results. Artifact images in PET could be described as hot or cold area and the images of infrequent physiological uptake were always shown as hot area. Conclusions The incidence of pitfall in PET/CT imaging was high and the causes of pitfalls are various. Among all causes that artifacts generated, respiratory motion is the most common. Some pitfalls may disturb clinical physicians' decision, so it is important to recognize artifacts and physiological uptake, and distinguish them from pathological uptakes.
基金The project supported by National Natural Science Foundation of China under Grant No. 10547005
文摘Based on the light nucleus reaction model (Nucl. Sci. Eng. 133 (1999) 218), four aspects (neutron incident energy region, reaction channel analysis, the renewed level schemes and the optical model parameters) of n+ ^12 C reaction are improved to calculate total outgoing neutron double-dilferential cross sections with modified LUNF code below 30 MeV. The calculated results agree fairly well with the experimental data at En = 14.1 MeV and 18 MeV. The analysis shows that the pre-equilibrium mechanism, which is exactly considered the conservation of energy, momentum and parity, dominates the whole reaction process. The contribution of the neutron emission from 5He to total energy- angular spectra is also considered properly. This modified LUNF code will be a useful tool to set up the file of neutron double-differential crass sections below 30 Me V in the neutron evaluation nuclear data library.
文摘A subspace-based blind Signal-to-Noise Ratio (SNR) estimation algorithm for digital bandpass signals in Additive White Gaussian Noise (AWGN) channel is discussed. The lower bounds of the mean and variance of the estimation are derived, and simulations are performed for the commonly used digital bandpass signals, such as MPSK (M=2, 4, 8), MFSK (M=2, 4) and MQAM (M=16, 64, 128, 256) signals. Theoretical analyses and simulation results indicate that the proposed algorithm is ef- fective even when the SNR is below 0dB. Furthermore, the algorithm can provide a blind estimator in that it needs neither the parameters of the received signals, such as the carrier frequency, symbol rate and modulation scheme, nor the synchronization of the system.
基金supported by the Ministry of Science and Technology (No.2017YFF0104500)the Chinese Academy of Sciences (No.XDB17000000)the National Natural Science Foundation of China (No.21573226, No.21822305)
文摘The reaction dynamics of the fluorine atom with vibrationally excited D2(v=1, v=0) was investigated using the crossed beam method. The scheme of stimulated Raman pumping was employed for preparation of vibrationally excited D2 molecules. Contribution from the reaction of spin-orbit excited F*(2P1/2) with vibrationally excited D2 was not found. Reaction of spin-orbit ground F(2P3/2) with vibrationally excited D2 was measured and DF products populated in v'=2, 3, 4, 5 were observed. Compared with the vibrationally ground reaction, DF products from the vibrationally excited reaction of F(2P3/2)+D2(v=1, j=0) are rotationally “hotter”. Differential cross sections at four collision energies, ranging from 0.32 kcal/mol to 2.62 kcal/mol, were obtained. Backward scattering dominates for DF products in all vibrational levels at the lowest collision energy of 0.32 kcal/mol. As the collision energy increases, angular distribution of DF products gradually shifts from backward to sideway. The collision-energy dependence of differential cross section of DF(v’=5) at forward direction was also measured. Forward-scattered signal of DF(v'=5) appears at the collision energy of 1.0 kcal/mol, and becomes dominated at 2.62 kcal/mol.
基金Project (No. TMU 85-05-33) supported in part by the Iran Telecommunication Research Center (ITRC)
文摘The diagnostic potential of brain positron emission tomography (PET) imaging is limited by low spatial resolution. For solving this problem we propose a technique for the fusion of PET and MRI images. This fusion is a trade-off between the spectral information extracted from PET images and the spatial information extracted from high spatial resolution MRI. The proposed method can control this trade-off. To achieve this goal, it is necessary to build a multiscale fusion model, based on the retinal cell photoreceptors model. This paper introduces general prospects of this model, and its application in multispectral medical image fusion. Results showed that the proposed method preserves more spectral features with less spatial distortion. Comparing with hue-intensity-saturation (HIS), discrete wavelet transform (DWT), wavelet-based sharpening and wavelet-a trous transform methods, the best spectral and spatial quality is only achieved simultaneously with the proposed feature-based data fusion method. This method does not require resampling images, which is an advantage over the other methods, and can perform in any aspect ratio between the pixels of MRI and PET images.