目的:探讨间断式全自动血细胞分离机对低血容量患者进行血浆置换。方法:用MCS+间断式全自动血细胞分离机对4例血容量≤3 000 m 患者进行血浆置换术,在术前及术中采取补充血容量的办法,以预防低血容量反应。结果:4例血浆置换术均达到了...目的:探讨间断式全自动血细胞分离机对低血容量患者进行血浆置换。方法:用MCS+间断式全自动血细胞分离机对4例血容量≤3 000 m 患者进行血浆置换术,在术前及术中采取补充血容量的办法,以预防低血容量反应。结果:4例血浆置换术均达到了治疗目的。结论:运用间断式全自动血细胞分离机对低容量患者开展血浆置换术效果理想。展开更多
A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filte...A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filter for MS. The sample ions were created at ambient pressure by ion source, which was equipped with a 10.6 eV UV discharge lamp (A=116.5 nm). The drift tube of FAIMS is composed of two parallel planar electrodes and the dimension is 10 mm×8 mm×0.5 mm. FAIMS was investigated when driven by the high-filed rectangular asymmetric waveform with the peak-to-peak voltage of 1.36 kV at the frequency of 1 MHz and the duty cycle of 30%. The acetone, the butanone, and their mixture were adopted to characterize the FAIMS-MS. The mass spectra obtained from MS illustrate that there are ion-molecular reactions between the ions and the sample neutral molecular. And the proton transfer behavior in the mixture of the acetone and the butanone is also observed. With the compensation voltage tuned from -30 V to 10 V with a step size of 0.1 V, the ion pre-separation before MS is realized.展开更多
A new method for the determination of Fe by thin layer resin phase spectrophotometry in alkali condition was reported. The complex anion formed by Fe(Ⅱ) and VA was absorbed on the 717w resin and Fe was determined b...A new method for the determination of Fe by thin layer resin phase spectrophotometry in alkali condition was reported. The complex anion formed by Fe(Ⅱ) and VA was absorbed on the 717w resin and Fe was determined by making thin layer. This method had a high sensitivity (ε620= 3.0×10^5L/mol.cm), which was 15 times higher than that of liquid phase spectrophotometry. It had been proved a satisfactory precision (5.01μg Fe, n=6, RSD=1.8%). The trace Fe in natural water was determined and the recovery was 97%.展开更多
文摘目的:探讨间断式全自动血细胞分离机对低血容量患者进行血浆置换。方法:用MCS+间断式全自动血细胞分离机对4例血容量≤3 000 m 患者进行血浆置换术,在术前及术中采取补充血容量的办法,以预防低血容量反应。结果:4例血浆置换术均达到了治疗目的。结论:运用间断式全自动血细胞分离机对低容量患者开展血浆置换术效果理想。
文摘A combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with mass spectrometer (MS) was analyzed. FAIMS separates ions from the volatile organic compounds in the gas-phase as an ion-filter for MS. The sample ions were created at ambient pressure by ion source, which was equipped with a 10.6 eV UV discharge lamp (A=116.5 nm). The drift tube of FAIMS is composed of two parallel planar electrodes and the dimension is 10 mm×8 mm×0.5 mm. FAIMS was investigated when driven by the high-filed rectangular asymmetric waveform with the peak-to-peak voltage of 1.36 kV at the frequency of 1 MHz and the duty cycle of 30%. The acetone, the butanone, and their mixture were adopted to characterize the FAIMS-MS. The mass spectra obtained from MS illustrate that there are ion-molecular reactions between the ions and the sample neutral molecular. And the proton transfer behavior in the mixture of the acetone and the butanone is also observed. With the compensation voltage tuned from -30 V to 10 V with a step size of 0.1 V, the ion pre-separation before MS is realized.
文摘A new method for the determination of Fe by thin layer resin phase spectrophotometry in alkali condition was reported. The complex anion formed by Fe(Ⅱ) and VA was absorbed on the 717w resin and Fe was determined by making thin layer. This method had a high sensitivity (ε620= 3.0×10^5L/mol.cm), which was 15 times higher than that of liquid phase spectrophotometry. It had been proved a satisfactory precision (5.01μg Fe, n=6, RSD=1.8%). The trace Fe in natural water was determined and the recovery was 97%.