The ultrasonic, magnetic and transport properties of Nd0.5Ca0.5Mn1-xAlxO3 (x=0, 0.03) were studied from 15 to 300 K. The temperature dependencies of resistivity and magnetization show that Nd0.5Ca0.5MnO3 undergoes a...The ultrasonic, magnetic and transport properties of Nd0.5Ca0.5Mn1-xAlxO3 (x=0, 0.03) were studied from 15 to 300 K. The temperature dependencies of resistivity and magnetization show that Nd0.5Ca0.5MnO3 undergoes a charge ordering transition at TCO-257 K. An obvious softening of the longitudinal sound velocity above TCO and a dramatic stiffening below Too accompanied by an attenuation peak were observed. These features imply a strong electron phonom interaction via the Jahn-Teller effect iu the sample, Another broad attenuation peak was observed at around Tp-80 K. This anomaly is attributed to the phase separtion between the antiferromagnetic (AFM) and paramagnetic (PM) phases and gives a direct evidence for spin-phonon coupling in the compound. For the x=0.03 sample, both the minimum of sound velocity and attenuation peaks shift to a lower temperature. The results indicate that the charge ordering and CE-type AFM state in Nd0.5Ca0.5MnO3 are both partially suppressed by replacing Mn with A1.展开更多
In order to examine the fundamental characteristics of corner separation in a decelerating cascade flow,the experimental apparatus was made and separations around a NACA65 blade in a decelerating channel flow were exa...In order to examine the fundamental characteristics of corner separation in a decelerating cascade flow,the experimental apparatus was made and separations around a NACA65 blade in a decelerating channel flow were examined.Two-dimensional calculations show that the NACA65 cascade flow that has 45 deg.of turning,1.24 of solidity and 17 deg.of stagger angle is equivalent to the channel flow that has 14 deg.of stagger angle in terms of pitchwise blade force.Experimental investigation by five-hole probe shows that the accumulations of low energy fluid can be seen around the corner part and the overturning flow due to the secondary flow exists.And,as the periodicity of the blade wake in a pitchwise direction is comparably good,the wake of this channel flow is similar to the wake of the cascade flow for two pitch portion.PIV measurement results shows that a vortex pattern can be seen in the momentary streamline on the suction surface of the blade and in the averaged streamline on the perpendicular to both the suction surface and the endwall.展开更多
An experimental investigation was made into three-dimensional separated flow and the vortices within the flow separation in a decelerating channel flow generated by the suction from a porous side wall. The flows along...An experimental investigation was made into three-dimensional separated flow and the vortices within the flow separation in a decelerating channel flow generated by the suction from a porous side wall. The flows along the side and bottom walls were visualized by the surface tuft method. The turbulent internal flow was measured by the split-film probe to investigate the turbulent flow including the reverse flow. In the flow visualization for the strong decelerating flow (the suction flow ratio:0.8), two typical flow patterns appear alternatively. One is that the flow near the bottom wall separates more upstream than the flow near the top wall and a clockwise vortex can be seen in the separation region. Another is the reversal flow pattern with a counterclockwise vortex. By the turbulent flow measurement using the split-film probe, two peaks of turbulence level are observed for the strong decelerating flow case. These peaks can be related with two flow patterns mentioned above.展开更多
基金supported by the National Natural Science Foundation of China(No.10274075)the Specialized Research Fund for the Doctoral Program of Higher Education(No.20030358056).
文摘The ultrasonic, magnetic and transport properties of Nd0.5Ca0.5Mn1-xAlxO3 (x=0, 0.03) were studied from 15 to 300 K. The temperature dependencies of resistivity and magnetization show that Nd0.5Ca0.5MnO3 undergoes a charge ordering transition at TCO-257 K. An obvious softening of the longitudinal sound velocity above TCO and a dramatic stiffening below Too accompanied by an attenuation peak were observed. These features imply a strong electron phonom interaction via the Jahn-Teller effect iu the sample, Another broad attenuation peak was observed at around Tp-80 K. This anomaly is attributed to the phase separtion between the antiferromagnetic (AFM) and paramagnetic (PM) phases and gives a direct evidence for spin-phonon coupling in the compound. For the x=0.03 sample, both the minimum of sound velocity and attenuation peaks shift to a lower temperature. The results indicate that the charge ordering and CE-type AFM state in Nd0.5Ca0.5MnO3 are both partially suppressed by replacing Mn with A1.
文摘In order to examine the fundamental characteristics of corner separation in a decelerating cascade flow,the experimental apparatus was made and separations around a NACA65 blade in a decelerating channel flow were examined.Two-dimensional calculations show that the NACA65 cascade flow that has 45 deg.of turning,1.24 of solidity and 17 deg.of stagger angle is equivalent to the channel flow that has 14 deg.of stagger angle in terms of pitchwise blade force.Experimental investigation by five-hole probe shows that the accumulations of low energy fluid can be seen around the corner part and the overturning flow due to the secondary flow exists.And,as the periodicity of the blade wake in a pitchwise direction is comparably good,the wake of this channel flow is similar to the wake of the cascade flow for two pitch portion.PIV measurement results shows that a vortex pattern can be seen in the momentary streamline on the suction surface of the blade and in the averaged streamline on the perpendicular to both the suction surface and the endwall.
文摘An experimental investigation was made into three-dimensional separated flow and the vortices within the flow separation in a decelerating channel flow generated by the suction from a porous side wall. The flows along the side and bottom walls were visualized by the surface tuft method. The turbulent internal flow was measured by the split-film probe to investigate the turbulent flow including the reverse flow. In the flow visualization for the strong decelerating flow (the suction flow ratio:0.8), two typical flow patterns appear alternatively. One is that the flow near the bottom wall separates more upstream than the flow near the top wall and a clockwise vortex can be seen in the separation region. Another is the reversal flow pattern with a counterclockwise vortex. By the turbulent flow measurement using the split-film probe, two peaks of turbulence level are observed for the strong decelerating flow case. These peaks can be related with two flow patterns mentioned above.