Harmonic suppression, non-periodic and non-closing in straightness profile error that will bring about harmonic component distortion in measurement result are analyzed. The countermeasure-a novel accurate two-probe me...Harmonic suppression, non-periodic and non-closing in straightness profile error that will bring about harmonic component distortion in measurement result are analyzed. The countermeasure-a novel accurate two-probe method in time domain is put forward to measure straight-going component motion error in machine tools based on the frequency domain 3-point method after symmetrical continuation of probes' primitive signal. Both straight-going component motion error in machine tools and the profile error in workpiece that is manufactured on this machine can be measured at the same time. The information is available to diagnose the fault origin of machine tools. The analysis result is proved to be correct by the experiment.展开更多
To evaluate measurement uncertainty for small sample size and measurement data from an unknown distribution, we propose a grey evaluation method of measurement uncertainty based on the grey relation coefficient. The u...To evaluate measurement uncertainty for small sample size and measurement data from an unknown distribution, we propose a grey evaluation method of measurement uncertainty based on the grey relation coefficient. The uncertainty of measurement is analyzed using grey system theory, and the defects of the grey evaluation model of measurement uncertainty (GEMU) are studied. We then establish an improved grey evaluation model of measurement uncertainty (IGEMU). Simulations show that the precision of IGEMU is greater than that of GEMU, and that sample size has only a small effect on the precision of IGEVU. In particular, IGEMU is applied to evaluating measurement uncertainty for small sample size and measurement data from an unknown distribution. The measurement uncertainty of total profile deviation, which is measured by the CNC gear measuring center, can be evaluated by a combination of IGEMU and the Monte Carlo method.展开更多
基金National Nature Science Foundation of China.No.50075056
文摘Harmonic suppression, non-periodic and non-closing in straightness profile error that will bring about harmonic component distortion in measurement result are analyzed. The countermeasure-a novel accurate two-probe method in time domain is put forward to measure straight-going component motion error in machine tools based on the frequency domain 3-point method after symmetrical continuation of probes' primitive signal. Both straight-going component motion error in machine tools and the profile error in workpiece that is manufactured on this machine can be measured at the same time. The information is available to diagnose the fault origin of machine tools. The analysis result is proved to be correct by the experiment.
基金supported by the National Natural Science Foundation of China (Grant Nos. 61108052 and 61108073)the Technology Program of the Educational Office of Hei Longjiang Province in China (Grant No.11553016)
文摘To evaluate measurement uncertainty for small sample size and measurement data from an unknown distribution, we propose a grey evaluation method of measurement uncertainty based on the grey relation coefficient. The uncertainty of measurement is analyzed using grey system theory, and the defects of the grey evaluation model of measurement uncertainty (GEMU) are studied. We then establish an improved grey evaluation model of measurement uncertainty (IGEMU). Simulations show that the precision of IGEMU is greater than that of GEMU, and that sample size has only a small effect on the precision of IGEVU. In particular, IGEMU is applied to evaluating measurement uncertainty for small sample size and measurement data from an unknown distribution. The measurement uncertainty of total profile deviation, which is measured by the CNC gear measuring center, can be evaluated by a combination of IGEMU and the Monte Carlo method.