The finite element method was used for analysis of raft foundation design in high-rise building.Compared with other conventional methods,this method is more adapted to the practical condition since both superstructure...The finite element method was used for analysis of raft foundation design in high-rise building.Compared with other conventional methods,this method is more adapted to the practical condition since both superstructure stiffness and soil conditions were considered in calculation.The calculation results by example show that the base reaction is more uniform and the maximum reaction decreases obviously.Accordingly,the raft foundation design is more economic without any loss of security for high-rise building.展开更多
The steel plate shear wall system has been used in a number of buildings as an innovative lateral force resistant system.Openings often exist in the steel plate shear walls due to the various functional requirements o...The steel plate shear wall system has been used in a number of buildings as an innovative lateral force resistant system.Openings often exist in the steel plate shear walls due to the various functional requirements of structures.These openings may negatively impact the lateral stiffness of steel plate shear walls.Therefore,an experimental research was instituted to investigate the seismic behavior of steel plate shear walls,with and without openings.The experimental results showed that steel plate shear walls have the satisfying seismic behavior,and,as expected,the strength and stiffness characteristics of the walls were reduced due to openings.Then a single-story wall panel FE model and an analytical deep beam model are developed in order to find the critical factors dominating the thickness reduction coefficient of wall panels with the opening.Furthermore,extensive parametric analysis is conducted to derive a simplified formula for the determination of the thickness reduction coefficient of wall panels with the opening for substituting solid wall panels with reduced thickness for actual wall panels with the opening.Finally,the design method for calculating the lateral stiffness is verified by some experimental programs and recommended for the routine practice of steel plate shear walls.展开更多
文摘The finite element method was used for analysis of raft foundation design in high-rise building.Compared with other conventional methods,this method is more adapted to the practical condition since both superstructure stiffness and soil conditions were considered in calculation.The calculation results by example show that the base reaction is more uniform and the maximum reaction decreases obviously.Accordingly,the raft foundation design is more economic without any loss of security for high-rise building.
基金supported by the National Key Technology R&D Program of China(Grant No.2011BAJ09B01)the National Natural Science Foundation of China(Grant Nos.51178246,51222810)Tsinghua University Initiative Scientific Research Program(Grant No.20101081766)
文摘The steel plate shear wall system has been used in a number of buildings as an innovative lateral force resistant system.Openings often exist in the steel plate shear walls due to the various functional requirements of structures.These openings may negatively impact the lateral stiffness of steel plate shear walls.Therefore,an experimental research was instituted to investigate the seismic behavior of steel plate shear walls,with and without openings.The experimental results showed that steel plate shear walls have the satisfying seismic behavior,and,as expected,the strength and stiffness characteristics of the walls were reduced due to openings.Then a single-story wall panel FE model and an analytical deep beam model are developed in order to find the critical factors dominating the thickness reduction coefficient of wall panels with the opening.Furthermore,extensive parametric analysis is conducted to derive a simplified formula for the determination of the thickness reduction coefficient of wall panels with the opening for substituting solid wall panels with reduced thickness for actual wall panels with the opening.Finally,the design method for calculating the lateral stiffness is verified by some experimental programs and recommended for the routine practice of steel plate shear walls.