A study was carried out to evaluate the treatment efficiency of modified model of septic tank(ST)for the treatment of domestic wastewater.The objective was to explore the possibility of increasing the removal effici...A study was carried out to evaluate the treatment efficiency of modified model of septic tank(ST)for the treatment of domestic wastewater.The objective was to explore the possibility of increasing the removal efficiency,at household level,thereby reducing cost and treatment burden on city level treatment plants.For this purpose,a bench scale model of ST was prepared and operated continuously for 78 days at different detention times i.e.,48,24 and 12 h and at two reactor temperatures viz.15℃ and 25℃.Domestic wastewater was fed to the bench scale ST without pre-settling.Research was conducted under two different arrangements.Firstly,by installing baffles in the bench scale ST(called Run-1 setup),and secondly by installing perforated plates between the baffles(called Run-2 setup).Results demonstrated that Run-2 setup is better than Run-1 setup.Temperature significantly affects the efficiency.Detention time of 24 h was found feasible.Run-2 setup demonstrated a percentage BOD removal of 45%with effluent BOD of 113 mg·L^-1 at 15℃ and 85%removal with effluent BOD of 31 mg·L^-1 at 25℃.It is concluded that if a modified design of ST using Run-2 setup is provided at household level,the effluent coming out of the house will meet the National Environmental Quality Standards(NEQS)when reactor temperature is close to 25℃.Development authorities are suggested to change their by-laws and make modified ST mandatory for all households.This may significantly reduce the cost and footprint of city level wastewater treatment plants being planned.展开更多
Tidal currents are a resource of great potentiality and not yet fully explored. Several efforts have been made to exploit these resources, but the costs associated to the deployment of tidal plants in marine environme...Tidal currents are a resource of great potentiality and not yet fully explored. Several efforts have been made to exploit these resources, but the costs associated to the deployment of tidal plants in marine environments are usually too high. The aim of this work is to present a system able to handle with the above mentioned problems, through the development of a particular hydrokinetic turbine design. In previous works, the authors described a basic turbine configuration achieving interesting performances, although some operational inconveniences were detected. Those problems have been existing so the solution should be optimized and redesigned. As a result, a new design of the turbine is proposed, consisting of a double rotor spinning in opposite directions in order to balance the induced mechanical torque. From preliminary evaluations related to the Messina Strait tidal cycles (Punta Pezzo site, RC, Italy), a single 12 m diameter turbine can supply a power of about 500 kW with a peak current speed of 3 m/s and deliver up to 450 MWh/year.展开更多
The paper presents to managers' and scholars' reasons for using models to determine the strategic importance of innovation and its potential value creation. The model of value based innovation (VBI) provides a cle...The paper presents to managers' and scholars' reasons for using models to determine the strategic importance of innovation and its potential value creation. The model of value based innovation (VBI) provides a clear definition of the adequate value curve to be pursued in any innovation action, from strategic definition to operational product conceptualization and production. The VBI model has been applied in strategic planning in over 100 SMEs throughout Portugal and USA by the authors and other consultant companies. The VBI model provides the practitioners and scholars with a pragmatic tool to determine innovation's value creation. Connecting this information with strategic thinking and planning will reduce risk and avoid failure. The theoretical model when converted into a technological application provides an immediate insight into the most adequate strategic innovation to be chosen by top management and operational product developers. The paper demonstrates the relation between innovation and value creation.展开更多
As the application undergraduate course colleges and universities, a distinctive talent training system must be formed to achieve the target of practical and innovative talents training, which needs to constantly expl...As the application undergraduate course colleges and universities, a distinctive talent training system must be formed to achieve the target of practical and innovative talents training, which needs to constantly explore and innovate teaching mode. In the paper, talent training model based on the occupation ability development and Excellence Engineer training has carried on the deep discussion and research, thorough study and research.展开更多
基金Funding by the University of Engineering&Technology,Lahore and support of lab staff
文摘A study was carried out to evaluate the treatment efficiency of modified model of septic tank(ST)for the treatment of domestic wastewater.The objective was to explore the possibility of increasing the removal efficiency,at household level,thereby reducing cost and treatment burden on city level treatment plants.For this purpose,a bench scale model of ST was prepared and operated continuously for 78 days at different detention times i.e.,48,24 and 12 h and at two reactor temperatures viz.15℃ and 25℃.Domestic wastewater was fed to the bench scale ST without pre-settling.Research was conducted under two different arrangements.Firstly,by installing baffles in the bench scale ST(called Run-1 setup),and secondly by installing perforated plates between the baffles(called Run-2 setup).Results demonstrated that Run-2 setup is better than Run-1 setup.Temperature significantly affects the efficiency.Detention time of 24 h was found feasible.Run-2 setup demonstrated a percentage BOD removal of 45%with effluent BOD of 113 mg·L^-1 at 15℃ and 85%removal with effluent BOD of 31 mg·L^-1 at 25℃.It is concluded that if a modified design of ST using Run-2 setup is provided at household level,the effluent coming out of the house will meet the National Environmental Quality Standards(NEQS)when reactor temperature is close to 25℃.Development authorities are suggested to change their by-laws and make modified ST mandatory for all households.This may significantly reduce the cost and footprint of city level wastewater treatment plants being planned.
文摘Tidal currents are a resource of great potentiality and not yet fully explored. Several efforts have been made to exploit these resources, but the costs associated to the deployment of tidal plants in marine environments are usually too high. The aim of this work is to present a system able to handle with the above mentioned problems, through the development of a particular hydrokinetic turbine design. In previous works, the authors described a basic turbine configuration achieving interesting performances, although some operational inconveniences were detected. Those problems have been existing so the solution should be optimized and redesigned. As a result, a new design of the turbine is proposed, consisting of a double rotor spinning in opposite directions in order to balance the induced mechanical torque. From preliminary evaluations related to the Messina Strait tidal cycles (Punta Pezzo site, RC, Italy), a single 12 m diameter turbine can supply a power of about 500 kW with a peak current speed of 3 m/s and deliver up to 450 MWh/year.
文摘The paper presents to managers' and scholars' reasons for using models to determine the strategic importance of innovation and its potential value creation. The model of value based innovation (VBI) provides a clear definition of the adequate value curve to be pursued in any innovation action, from strategic definition to operational product conceptualization and production. The VBI model has been applied in strategic planning in over 100 SMEs throughout Portugal and USA by the authors and other consultant companies. The VBI model provides the practitioners and scholars with a pragmatic tool to determine innovation's value creation. Connecting this information with strategic thinking and planning will reduce risk and avoid failure. The theoretical model when converted into a technological application provides an immediate insight into the most adequate strategic innovation to be chosen by top management and operational product developers. The paper demonstrates the relation between innovation and value creation.
文摘As the application undergraduate course colleges and universities, a distinctive talent training system must be formed to achieve the target of practical and innovative talents training, which needs to constantly explore and innovate teaching mode. In the paper, talent training model based on the occupation ability development and Excellence Engineer training has carried on the deep discussion and research, thorough study and research.