A novel modeling method which can restore the shape of the femoral head with collapse induced by ischemic necrosis is proposed. First, sequential tomograms of the hip are obtained from a CT scan; secondly, an accurate...A novel modeling method which can restore the shape of the femoral head with collapse induced by ischemic necrosis is proposed. First, sequential tomograms of the hip are obtained from a CT scan; secondly, an accurate and automatic method is used to extract the profile of the acetabulum; thirdly, a hybrid method is utilized to gather fiducial marks on the acetabulum; fourthly, bulky error sampling points are removed. Finally, an ellipsoid fitting method is used to fit the ellipsoid model of the femoral head. Two male sufferers with different necrosis extents are chosen as experimental subjects for contrastive simulation. Fifty cases of different ages (from 25 to 79 years old) are utilized for statistical comparisons of matching errors. The prosthetic models highly resemble the primary shape of the femoral head in health. This new method provides not only a theoretical model for accurate operation position fixing in an orthopaedics clinic, but it is also an innovative practical means for the individual manufacture of artificial femoral heads.展开更多
基金The National High Technology Research and Development Program of China(863 Program)(No.863-306-ZD13-03-6)the High Technology Research and Development Program of Dalian City(No.2005E21SF134)
文摘A novel modeling method which can restore the shape of the femoral head with collapse induced by ischemic necrosis is proposed. First, sequential tomograms of the hip are obtained from a CT scan; secondly, an accurate and automatic method is used to extract the profile of the acetabulum; thirdly, a hybrid method is utilized to gather fiducial marks on the acetabulum; fourthly, bulky error sampling points are removed. Finally, an ellipsoid fitting method is used to fit the ellipsoid model of the femoral head. Two male sufferers with different necrosis extents are chosen as experimental subjects for contrastive simulation. Fifty cases of different ages (from 25 to 79 years old) are utilized for statistical comparisons of matching errors. The prosthetic models highly resemble the primary shape of the femoral head in health. This new method provides not only a theoretical model for accurate operation position fixing in an orthopaedics clinic, but it is also an innovative practical means for the individual manufacture of artificial femoral heads.