Removal of Co(Ⅱ) from aqueous solutions by complexation-ultrafiltration was investigated using polyacrylic acid sodium(PAAS) as complexing agent with the help of rotating disk membrane,and the shear ability of PAA-Co...Removal of Co(Ⅱ) from aqueous solutions by complexation-ultrafiltration was investigated using polyacrylic acid sodium(PAAS) as complexing agent with the help of rotating disk membrane,and the shear ability of PAA-Co complex was studied. The effects of the mass ratio of PAAS to Co(Ⅱ)(P/M) and pH on the rejection of Co(Ⅱ) were studied,and the optimum conditions were P/M=8 and pH=7. The rejection of Co(Ⅱ) was over 97% when the rotating speed of the disk(n)was less than 710 r/min at the optimum P/M and pH. The distribution of the forms of cobalt on the membrane surface was established by the membrane partition model, and the critical shear rate,the smallest shear rate at which the PAA-Co complex begins to dissociate,was calculated to be1.4×10^4 s^-1,and the corresponding rotating speed was 710 r/min.The PAA-Co complex dissociated when the shear rate was greater than the critical one. The regeneration of PAAS and recovery of Co(Ⅱ) were achieved by shear-induced dissociation and ultrafiltration.展开更多
Copolymer of acrylic acid and maleic acid(PMA)was used to remove Hg^2+from aqueous solution by complexation-ultrafiltration(C-UF)through rotating disk membrane(RDM).The effects of P/M(mass ratio of PMA to metal ions),...Copolymer of acrylic acid and maleic acid(PMA)was used to remove Hg^2+from aqueous solution by complexation-ultrafiltration(C-UF)through rotating disk membrane(RDM).The effects of P/M(mass ratio of PMA to metal ions),pH and rotation speed(N)on the interception of Hg^2+were investigated.The interception could reach 99.7%at pH 7.0,P/M 6 and N less than 1890 r/min.The shear stability of PMA-Hg complex was studied by RDM.The critical rotation speed,at which the interception starts to decrease,was 1890 r/min,and the critical shear rate,the smallest shear rate at which PMA-Hg complex begins to dissociate,was 2.50×10^5s^-1 at pH 7.0.Furthermore,the critical radii were obtained at different rotation speeds and pHs.The results showed that the critical radius decreased with the rotation speed and increased with pH.Shear induced dissociation coupling with ultra?ltration(SID-UF)was efficiently used to recover Hg^2+and PMA.展开更多
基金supported by the National Natural Science Foundation of China(No.22178392)the Fundamental Research Funds for the Central Universities of Central South University,China(No.2022ZZTS0493)。
基金Project(24176265)supported by the National Natural Science Foundation of China
文摘Removal of Co(Ⅱ) from aqueous solutions by complexation-ultrafiltration was investigated using polyacrylic acid sodium(PAAS) as complexing agent with the help of rotating disk membrane,and the shear ability of PAA-Co complex was studied. The effects of the mass ratio of PAAS to Co(Ⅱ)(P/M) and pH on the rejection of Co(Ⅱ) were studied,and the optimum conditions were P/M=8 and pH=7. The rejection of Co(Ⅱ) was over 97% when the rotating speed of the disk(n)was less than 710 r/min at the optimum P/M and pH. The distribution of the forms of cobalt on the membrane surface was established by the membrane partition model, and the critical shear rate,the smallest shear rate at which the PAA-Co complex begins to dissociate,was calculated to be1.4×10^4 s^-1,and the corresponding rotating speed was 710 r/min.The PAA-Co complex dissociated when the shear rate was greater than the critical one. The regeneration of PAAS and recovery of Co(Ⅱ) were achieved by shear-induced dissociation and ultrafiltration.
基金Project(21476265)supported by the National Natural Science Foundation of China。
文摘Copolymer of acrylic acid and maleic acid(PMA)was used to remove Hg^2+from aqueous solution by complexation-ultrafiltration(C-UF)through rotating disk membrane(RDM).The effects of P/M(mass ratio of PMA to metal ions),pH and rotation speed(N)on the interception of Hg^2+were investigated.The interception could reach 99.7%at pH 7.0,P/M 6 and N less than 1890 r/min.The shear stability of PMA-Hg complex was studied by RDM.The critical rotation speed,at which the interception starts to decrease,was 1890 r/min,and the critical shear rate,the smallest shear rate at which PMA-Hg complex begins to dissociate,was 2.50×10^5s^-1 at pH 7.0.Furthermore,the critical radii were obtained at different rotation speeds and pHs.The results showed that the critical radius decreased with the rotation speed and increased with pH.Shear induced dissociation coupling with ultra?ltration(SID-UF)was efficiently used to recover Hg^2+and PMA.