A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The t...A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The topology of a single-phase CCM and DCM Boost-PFC switching converter was also analyzed.Its operating prniciples and control methods were expounded.Based on these,a new type of AC/DC switching converter circuits for PFC combined with one-cycle control technology was presented herein.The proposed AC/DC switching converter significantly helps improve the converter efficiency and its power factor value.展开更多
For the battery only power system is hard to meet the energy and power requirements reasonably, a hybrid power system with uhracapacitor and battery is studied. A Topology structure is analyzed that the uhracapacitor ...For the battery only power system is hard to meet the energy and power requirements reasonably, a hybrid power system with uhracapacitor and battery is studied. A Topology structure is analyzed that the uhracapacitor system is connected with battery pack parallel after a bidirectional DC/DC converter. The ultracapacitor, battery and the hybrid power system are modeled. For the plug-in hybrid electric vehicle (PHEV) application, the control target and control strategy of the hybrid power system are put forward. From the simulation results based on the Chinese urban driving cycle, the hybrid power system could meet the peak power requirements reasonably while the battery pack' s current is controlled in a reasonable limit which will be helpful to optimize the battery pack' s working conditions to get long cycling life and high efficiency.展开更多
This paper presents a comprehensive overview study of the DDPMSG (direct driven permanent magnet synchronous generator) for wind energy generation system. Wind turbine controls are provided. The PMSG (permanent mag...This paper presents a comprehensive overview study of the DDPMSG (direct driven permanent magnet synchronous generator) for wind energy generation system. Wind turbine controls are provided. The PMSG (permanent magnet synchronous generator) is introduced as construction and model. Configurations of different power converters are presented for use with DDPMSG in wind systems at variable speed operation and maximum power capture. Control techniques for the system are discussed for both machine-side and grid-side in details. Grid integration is provided with focus on how to insure power quality of the system and the performance at disturbances.展开更多
In order to ensure power system stability, modern wind turbines are required to be able to endure deep voltage dips. The specifications that determine the voltage dip versus time are called fault r/de-through (FRT) ...In order to ensure power system stability, modern wind turbines are required to be able to endure deep voltage dips. The specifications that determine the voltage dip versus time are called fault r/de-through (FRT) requirements. The purpose of this paper is not only to examine the FRT behavior of a full-power converter wind turbine but also to combine the power system viewpoint to the studies. It is not enough for the turbine to be FRT capable; the loss of mains (LOM) protection of the turbine must also be set to allow the FRT. Enabling FRT, however, means that the LOM protection settings must be loosen, which may sometimes pose a safety hazard. This article introduces unique real-time simulation environment and proposes an FRT method for a wind turbine that also takes the operation of LOM protection relay into account. Simulations are carried out using the simulation environment and results show that wind turbine is able to ride-through a symmetrical power system fault.展开更多
The conventional structures in the Switched Reluctance machines are introduced, such as three-phase 12/8 structure Switched Reluctance machine, three-phase 6/4 structure Switched Reluctance machine, four-phase 16/12 s...The conventional structures in the Switched Reluctance machines are introduced, such as three-phase 12/8 structure Switched Reluctance machine, three-phase 6/4 structure Switched Reluctance machine, four-phase 16/12 structure Switched Reluctance machine, and four-phase 8/6 structure Switched Reluctance machine. Three-phase 12/8 structure Switched Reluctance machine is the best choice for the large power Switched Reluctance machine system in coal mines. The asymmetric bridge power converter main circuit and the bifilar winding power converter main circuit are also introduced. Three-phase asymmetric bridge power converter main circuit is the best choice for the large power Switched Reluctance machine system in coal mines. The magnetic paths of the designed large power motor are given with one phase excitation and double phases excitation. The phase current waveforms are also given.展开更多
The paper deals with impulse switching function which are used as exciting functions of one- and multidimensional state-space models of power electronic converters. Obviously, these functions are harmonic but using po...The paper deals with impulse switching function which are used as exciting functions of one- and multidimensional state-space models of power electronic converters. Obviously, these functions are harmonic but using power converters they can be strongly non-harmonic, sometimes piecewise constants with zero spaces between them. Then, one deals with power series of time pulses. The impulse switching functions which are orthogonal ones can be derived from these series. The new impulse switching functions are created using Z-transform, inverse Z-transform and numerical series/sequences. The impulse switching functions created this way can be used for both steady- and transient state investigation of converters.展开更多
The reliability plays an important role in power electronic systems by which the number of system failures, repair costs, guarantee and etc. are estimated. In this paper first, a boost Maximum Power Point Tracker (M...The reliability plays an important role in power electronic systems by which the number of system failures, repair costs, guarantee and etc. are estimated. In this paper first, a boost Maximum Power Point Tracker (MPPT) converter is simulated in Discontinues Conduction Mode (DCM) and Continuous Conduction Mode (CCM) under different output power ratings. For these simulations, all of the inherent parameters of MOSFET and diodes are applied according to the actual types. Then, reliability calculation is done based on MIL-HDBK-217 handbook. Results have shown that the MPPT converter would have better performance from reliability point of view in CCM operating mode.展开更多
This paper proposes a high performance double-interleaved dual boost (DIDB) technique to solve the problems of high ripple current, large inductor size and the requirement of step-up transformer in many case found i...This paper proposes a high performance double-interleaved dual boost (DIDB) technique to solve the problems of high ripple current, large inductor size and the requirement of step-up transformer in many case found in the conventional DC-DC boost converter. The 3-phase grid connected converter with decoupling control give an independent control between active and reactive power using the load current feed-forward. With this technique, the disturbance rejection and the output power quality can be improved. Experiments are conducted with three case studies: 1) a test of the DIDB converter to determine current ripple and voltage gain, 2) a test of the 3-phase grid connected converter to determine DC-link voltage regulation, power factor and total harmonic distortion (THD), and 3) a test of the overall system with a 7.5 kW wind turbine simulator by step and various input wind speeds to determine the output power at the grid side and verify the maximum peak power tracking (MPPT) performance. The results can confirm that the DIDB converter gives lower ripple current and higher voltage gain than the conventional converter. For the grid side, the 3-phase grid connected converter can regulate the DC-link with fast dynamic response to disturbance rejection and low overshoot while complying with the THD standard defined in IEEE 519-1992. In addition, the MPPT controller is able to achieve the maximum energy capture with the various input wind speeds.展开更多
文摘A new family of converters,high-performance AC/DC power factor correction(PFC) switching converters with one-cycle control technology and active floating-charge technology,was derived and experimentally verified.The topology of a single-phase CCM and DCM Boost-PFC switching converter was also analyzed.Its operating prniciples and control methods were expounded.Based on these,a new type of AC/DC switching converter circuits for PFC combined with one-cycle control technology was presented herein.The proposed AC/DC switching converter significantly helps improve the converter efficiency and its power factor value.
文摘For the battery only power system is hard to meet the energy and power requirements reasonably, a hybrid power system with uhracapacitor and battery is studied. A Topology structure is analyzed that the uhracapacitor system is connected with battery pack parallel after a bidirectional DC/DC converter. The ultracapacitor, battery and the hybrid power system are modeled. For the plug-in hybrid electric vehicle (PHEV) application, the control target and control strategy of the hybrid power system are put forward. From the simulation results based on the Chinese urban driving cycle, the hybrid power system could meet the peak power requirements reasonably while the battery pack' s current is controlled in a reasonable limit which will be helpful to optimize the battery pack' s working conditions to get long cycling life and high efficiency.
文摘This paper presents a comprehensive overview study of the DDPMSG (direct driven permanent magnet synchronous generator) for wind energy generation system. Wind turbine controls are provided. The PMSG (permanent magnet synchronous generator) is introduced as construction and model. Configurations of different power converters are presented for use with DDPMSG in wind systems at variable speed operation and maximum power capture. Control techniques for the system are discussed for both machine-side and grid-side in details. Grid integration is provided with focus on how to insure power quality of the system and the performance at disturbances.
文摘In order to ensure power system stability, modern wind turbines are required to be able to endure deep voltage dips. The specifications that determine the voltage dip versus time are called fault r/de-through (FRT) requirements. The purpose of this paper is not only to examine the FRT behavior of a full-power converter wind turbine but also to combine the power system viewpoint to the studies. It is not enough for the turbine to be FRT capable; the loss of mains (LOM) protection of the turbine must also be set to allow the FRT. Enabling FRT, however, means that the LOM protection settings must be loosen, which may sometimes pose a safety hazard. This article introduces unique real-time simulation environment and proposes an FRT method for a wind turbine that also takes the operation of LOM protection relay into account. Simulations are carried out using the simulation environment and results show that wind turbine is able to ride-through a symmetrical power system fault.
基金Project 2008DFA61870 supported by the International S&T Cooperation Program of Chinathe Project [2008]221-12-1 supported by the Chinese-Bulgarian Scientific and Technological Cooperation Project
文摘The conventional structures in the Switched Reluctance machines are introduced, such as three-phase 12/8 structure Switched Reluctance machine, three-phase 6/4 structure Switched Reluctance machine, four-phase 16/12 structure Switched Reluctance machine, and four-phase 8/6 structure Switched Reluctance machine. Three-phase 12/8 structure Switched Reluctance machine is the best choice for the large power Switched Reluctance machine system in coal mines. The asymmetric bridge power converter main circuit and the bifilar winding power converter main circuit are also introduced. Three-phase asymmetric bridge power converter main circuit is the best choice for the large power Switched Reluctance machine system in coal mines. The magnetic paths of the designed large power motor are given with one phase excitation and double phases excitation. The phase current waveforms are also given.
文摘The paper deals with impulse switching function which are used as exciting functions of one- and multidimensional state-space models of power electronic converters. Obviously, these functions are harmonic but using power converters they can be strongly non-harmonic, sometimes piecewise constants with zero spaces between them. Then, one deals with power series of time pulses. The impulse switching functions which are orthogonal ones can be derived from these series. The new impulse switching functions are created using Z-transform, inverse Z-transform and numerical series/sequences. The impulse switching functions created this way can be used for both steady- and transient state investigation of converters.
文摘The reliability plays an important role in power electronic systems by which the number of system failures, repair costs, guarantee and etc. are estimated. In this paper first, a boost Maximum Power Point Tracker (MPPT) converter is simulated in Discontinues Conduction Mode (DCM) and Continuous Conduction Mode (CCM) under different output power ratings. For these simulations, all of the inherent parameters of MOSFET and diodes are applied according to the actual types. Then, reliability calculation is done based on MIL-HDBK-217 handbook. Results have shown that the MPPT converter would have better performance from reliability point of view in CCM operating mode.
文摘This paper proposes a high performance double-interleaved dual boost (DIDB) technique to solve the problems of high ripple current, large inductor size and the requirement of step-up transformer in many case found in the conventional DC-DC boost converter. The 3-phase grid connected converter with decoupling control give an independent control between active and reactive power using the load current feed-forward. With this technique, the disturbance rejection and the output power quality can be improved. Experiments are conducted with three case studies: 1) a test of the DIDB converter to determine current ripple and voltage gain, 2) a test of the 3-phase grid connected converter to determine DC-link voltage regulation, power factor and total harmonic distortion (THD), and 3) a test of the overall system with a 7.5 kW wind turbine simulator by step and various input wind speeds to determine the output power at the grid side and verify the maximum peak power tracking (MPPT) performance. The results can confirm that the DIDB converter gives lower ripple current and higher voltage gain than the conventional converter. For the grid side, the 3-phase grid connected converter can regulate the DC-link with fast dynamic response to disturbance rejection and low overshoot while complying with the THD standard defined in IEEE 519-1992. In addition, the MPPT controller is able to achieve the maximum energy capture with the various input wind speeds.