With rapid economy growth,building energy consumption in China has been gradually increased.The energy consumption and indoor environmental quality of 51 office buildings in Hainan Province,a hot and humid area,were s...With rapid economy growth,building energy consumption in China has been gradually increased.The energy consumption and indoor environmental quality of 51 office buildings in Hainan Province,a hot and humid area,were studied through collection of verified data in site visits and field tests.The result revealed that,electricity accounted for 99.79% of the total energy consumption,natural gas 0.17%,and diesel 0.04%.The air conditioning dominated the energy use with a share of 43.18%,equipment in the particular areas 26.90%,equipment in the office rooms 11.95%,lighting system 8.67%,general service system 7.57%,and miscellaneous items 1.73%.Statistical method including six indicators obtained the energy consumption benchmark with upper limit of 98.31 kW-h/m2 and lower limit of 55.26 kW-h/m2.According to ASHRAE standard(comfortable standard) and GB/T 18883-2002(acceptable standard),the indoor environmental quality of 51 sampled office buildings was classified into three ranks:good,normal and bad.With benchmark of building energy consumption combined with indoor environmental quality,it was found that only 3.92% of sampled buildings can be identified as the best performance buildings with low energy consumption and advanced indoor environmental quality,and the buildings classified into normal level accounted for the maximum ratio.展开更多
This paper explores the shift in the attitudes of building developer/owners to the incorporation of sustainability measures into office building renovations in New Zealand over the last 7 years, through a series of in...This paper explores the shift in the attitudes of building developer/owners to the incorporation of sustainability measures into office building renovations in New Zealand over the last 7 years, through a series of interviews with a wide range of key industry players and the study of three seminal case study examples. The interviewees uniformly considered that there had been a rapid increase in interest in the green renovation of existing buildings during the period under consideration, due mainly to strong leadership by central government. Significant differences in attitudes to green renovation emerged between the various groups as to whether, and on what terms such developments were likely to occur. The move to green building solutions seems to have continued in New Zealand, despite the world financial crisis and central government's abrogation of its leadership role being replaced by rising tenant expectations and the need for building owners to let their premises in a more competitive leasing environment. The change in attitudes demonstrated is profound. In the earliest of the case study buildings, started on site in 2004, no consideration is given by the developer, owner or design team to sustainability issues and there is no obvious user demand. In the second case, which started on site only one year later, sustainable design is very prominent, but is largely tenant driven, albeit with the active and enthusiastic support of the developer and design team. The final case study building started on site in 2007 is entirely developer/building owner driven and stems from a perception that "green" buildings represent value for money, that there is a real and persistent user demand and that sustainable design makes strong commercial sense.展开更多
Even all indoor environmental standards are met the users are usually not satisfied and perceived discomfort is occurred in the smart office buildings. The most frequently cause of discomfort in smart buildings is ove...Even all indoor environmental standards are met the users are usually not satisfied and perceived discomfort is occurred in the smart office buildings. The most frequently cause of discomfort in smart buildings is overrun of intelligence. There are physical and psychological factors that influenced building users' comfort. An indoor air quality seems to be one of the main problems of smart office buildings. In Slovakia the office buildings relating to indoor environment European standard are mostly evaluated as the non-low polluting buildings. The pollution from building as well as the pollution from occupancy and using was respected. The odor intensity and indoor air acceptability were assessed by a sensory panel. The concentrations of total volatile organic compounds and carbon dioxide were measured. The odors from building materials studied under different air change rate are presented in this paper. The case study of indoor air acceptability concerning to indoor odors under occupancy and its affect on perceived air quality influenced by air change rate are also presented in this paper.展开更多
基金Project(2011BAJ01B05) supported by the National Science and Technology Pillar Program during the Twelfth Five-year Plan Period of China
文摘With rapid economy growth,building energy consumption in China has been gradually increased.The energy consumption and indoor environmental quality of 51 office buildings in Hainan Province,a hot and humid area,were studied through collection of verified data in site visits and field tests.The result revealed that,electricity accounted for 99.79% of the total energy consumption,natural gas 0.17%,and diesel 0.04%.The air conditioning dominated the energy use with a share of 43.18%,equipment in the particular areas 26.90%,equipment in the office rooms 11.95%,lighting system 8.67%,general service system 7.57%,and miscellaneous items 1.73%.Statistical method including six indicators obtained the energy consumption benchmark with upper limit of 98.31 kW-h/m2 and lower limit of 55.26 kW-h/m2.According to ASHRAE standard(comfortable standard) and GB/T 18883-2002(acceptable standard),the indoor environmental quality of 51 sampled office buildings was classified into three ranks:good,normal and bad.With benchmark of building energy consumption combined with indoor environmental quality,it was found that only 3.92% of sampled buildings can be identified as the best performance buildings with low energy consumption and advanced indoor environmental quality,and the buildings classified into normal level accounted for the maximum ratio.
文摘This paper explores the shift in the attitudes of building developer/owners to the incorporation of sustainability measures into office building renovations in New Zealand over the last 7 years, through a series of interviews with a wide range of key industry players and the study of three seminal case study examples. The interviewees uniformly considered that there had been a rapid increase in interest in the green renovation of existing buildings during the period under consideration, due mainly to strong leadership by central government. Significant differences in attitudes to green renovation emerged between the various groups as to whether, and on what terms such developments were likely to occur. The move to green building solutions seems to have continued in New Zealand, despite the world financial crisis and central government's abrogation of its leadership role being replaced by rising tenant expectations and the need for building owners to let their premises in a more competitive leasing environment. The change in attitudes demonstrated is profound. In the earliest of the case study buildings, started on site in 2004, no consideration is given by the developer, owner or design team to sustainability issues and there is no obvious user demand. In the second case, which started on site only one year later, sustainable design is very prominent, but is largely tenant driven, albeit with the active and enthusiastic support of the developer and design team. The final case study building started on site in 2007 is entirely developer/building owner driven and stems from a perception that "green" buildings represent value for money, that there is a real and persistent user demand and that sustainable design makes strong commercial sense.
文摘Even all indoor environmental standards are met the users are usually not satisfied and perceived discomfort is occurred in the smart office buildings. The most frequently cause of discomfort in smart buildings is overrun of intelligence. There are physical and psychological factors that influenced building users' comfort. An indoor air quality seems to be one of the main problems of smart office buildings. In Slovakia the office buildings relating to indoor environment European standard are mostly evaluated as the non-low polluting buildings. The pollution from building as well as the pollution from occupancy and using was respected. The odor intensity and indoor air acceptability were assessed by a sensory panel. The concentrations of total volatile organic compounds and carbon dioxide were measured. The odors from building materials studied under different air change rate are presented in this paper. The case study of indoor air acceptability concerning to indoor odors under occupancy and its affect on perceived air quality influenced by air change rate are also presented in this paper.