This paper presents an improved Voice Activity Detection (VAD) algorithm which uses the Signal-to-Noise Ratio (SNR) measure. We assume that noise Power Spectral Density (PSD) in each spectral bin follows a Rayle...This paper presents an improved Voice Activity Detection (VAD) algorithm which uses the Signal-to-Noise Ratio (SNR) measure. We assume that noise Power Spectral Density (PSD) in each spectral bin follows a Rayleigh distribution. Rayleigh distributions with its asymmetric tail characteristics give a better description of the noise PSD distribution than Gaussian distribution. Under this asstlmption, a new threshold updating expression is derived. Since the analytical integral of the false alarm probability, the threshold updating expression can be represented without the inverse complementary error function and low computational complexity is achieved in our system. Experimental results show that the proposed VAD outperforms or at least is comparable with the VAD scheme presented by Davis under several noise environments and has a lower computational complexity.展开更多
The purpose of the paper is to develop a solution for application of PV (photovoltaic) generators in MV (medium voltage) distribution system without unacceptable voltage changes due to drops of PV power output. Th...The purpose of the paper is to develop a solution for application of PV (photovoltaic) generators in MV (medium voltage) distribution system without unacceptable voltage changes due to drops of PV power output. The proposed solution includes operation of PV with predetermined leading power factor and addition of a capacitor bank in parallel to PV plant in order to compensate the reactive power absorbed by the PV inverters. The analytical expression of required power factor angle is derived. Adding a capacitor bank in parallel to PV power plant may pose a problem because of space limitations. The dimensions and cost of small MV capacitor banks depend significantly on the capacitor bank protection against internal faults. Application of the developed negative-sequence current difference method for the unbalance protection of the capacitor banks enables to achieve a compact and cost-reduced design of the banks connected in parallel to PV power plants. A real-world example of operation of the PV plant in parallel to the capacitor bank with the novel protection scheme is described.展开更多
In this study,by means of homotopy perturbation method(HPM) an approximate solution of the magnetohydrodynamic(MHD) boundary layer flow is obtained.The main feature of the HPM is that it deforms a difficult problem in...In this study,by means of homotopy perturbation method(HPM) an approximate solution of the magnetohydrodynamic(MHD) boundary layer flow is obtained.The main feature of the HPM is that it deforms a difficult problem into a set of problems which are easier to solve.HPM produces analytical expressions for the solution to nonlinear differential equations.The obtained analytic solution is in the form of an infinite power series.In this work,the analytical solution obtained by using only two terms from HPM solution.Comparisons with the exact solution and the solution obtained by the Pade approximants and shooting method show the high accuracy,simplicity and efficiency of this method.展开更多
基金Supported by the National Natural Science Foundation of China (No. 60874060)
文摘This paper presents an improved Voice Activity Detection (VAD) algorithm which uses the Signal-to-Noise Ratio (SNR) measure. We assume that noise Power Spectral Density (PSD) in each spectral bin follows a Rayleigh distribution. Rayleigh distributions with its asymmetric tail characteristics give a better description of the noise PSD distribution than Gaussian distribution. Under this asstlmption, a new threshold updating expression is derived. Since the analytical integral of the false alarm probability, the threshold updating expression can be represented without the inverse complementary error function and low computational complexity is achieved in our system. Experimental results show that the proposed VAD outperforms or at least is comparable with the VAD scheme presented by Davis under several noise environments and has a lower computational complexity.
文摘The purpose of the paper is to develop a solution for application of PV (photovoltaic) generators in MV (medium voltage) distribution system without unacceptable voltage changes due to drops of PV power output. The proposed solution includes operation of PV with predetermined leading power factor and addition of a capacitor bank in parallel to PV plant in order to compensate the reactive power absorbed by the PV inverters. The analytical expression of required power factor angle is derived. Adding a capacitor bank in parallel to PV power plant may pose a problem because of space limitations. The dimensions and cost of small MV capacitor banks depend significantly on the capacitor bank protection against internal faults. Application of the developed negative-sequence current difference method for the unbalance protection of the capacitor banks enables to achieve a compact and cost-reduced design of the banks connected in parallel to PV power plants. A real-world example of operation of the PV plant in parallel to the capacitor bank with the novel protection scheme is described.
文摘In this study,by means of homotopy perturbation method(HPM) an approximate solution of the magnetohydrodynamic(MHD) boundary layer flow is obtained.The main feature of the HPM is that it deforms a difficult problem into a set of problems which are easier to solve.HPM produces analytical expressions for the solution to nonlinear differential equations.The obtained analytic solution is in the form of an infinite power series.In this work,the analytical solution obtained by using only two terms from HPM solution.Comparisons with the exact solution and the solution obtained by the Pade approximants and shooting method show the high accuracy,simplicity and efficiency of this method.