The goal of the present paper is to expand already published works in the frame of"Banded speed cosmology" (BSC). In particular this paper gives validated values for physical quantities not so far investigated in ...The goal of the present paper is to expand already published works in the frame of"Banded speed cosmology" (BSC). In particular this paper gives validated values for physical quantities not so far investigated in previous publications, i.e., the number of individual physical entity in the universe, as well as the maximum value for acceleration. Validates values mean identical quantities from a numerical point of view obtained with different theoretical procedures, additionally compared with data based on NASA observations with Planck probe.展开更多
In this paper, on the basis of the implementation of the national chemical industry standard analytical test methods and analysis of test items, a food additive quality analysis and inspection of network management ap...In this paper, on the basis of the implementation of the national chemical industry standard analytical test methods and analysis of test items, a food additive quality analysis and inspection of network management applications are developed using the development technology of Visual Basic language and computer system operating environment, to achieve a network management software for users on food additives of quality analytical testing. The software sets up an information sharing network platform for enterprise and quality management departments, which is a major innovation in the food additive quality analysis on test management methods and tools.展开更多
Astronaut's body mass is an essential factor of health monitoring in space.The latest mass measurement device for the International Space Station (ISS) has employed a linear acceleration method.The principle of th...Astronaut's body mass is an essential factor of health monitoring in space.The latest mass measurement device for the International Space Station (ISS) has employed a linear acceleration method.The principle of this method is that the device generates a constant pulling force,and the astronaut is accelerated on a parallelogram motion guide which rotates at a large radius to achieve a nearly linear trajectory.The acceleration is calculated by regression analysis of the displacement versus time trajectory and the body mass is calculated by using the formula m=F/a.However,in actual flight,the device is instable that the deviation between runs could be 6-7 kg.This paper considers the body non-rigidity as the major cause of error and instability and analyzes the effects of body non-rigidity from different aspects.Body non-rigidity makes the acceleration of the center of mass (C.M.) oscillate and fall behind the point where force is applied.Actual acceleration curves showed that the overall effect of body non-rigidity is an oscillation at about 7 Hz and a deviation of about 25%.To enhance body rigidity,better body restraints were introduced and a prototype based on linear acceleration method was built.Measurement experiment was carried out on ground on an air table.Three human subjects weighing 60-70 kg were measured.The average variance was 0.04 kg and the average measurement error was 0.4%.This study will provide reference for future development of China's own mass measurement device.展开更多
The 53.667 MHz continuous-wave heavy ion RFQ has been designed and manufactured for the SSC-LINAC project.This four-rod RFQ accelerates ions with maximum mass to charge ratio of 7 from 3.728 keV/u to 143 keV/u.Measure...The 53.667 MHz continuous-wave heavy ion RFQ has been designed and manufactured for the SSC-LINAC project.This four-rod RFQ accelerates ions with maximum mass to charge ratio of 7 from 3.728 keV/u to 143 keV/u.Measurements have been carried out to check the RF performance of the cavity and the quality of the electric field.The S11 of the power coupler is adjusted to better than-44 dB,and the Q0 of the cavity is 6440.The quality of the electric field is evaluated by the perturbation method.The measurement procedure and data analysis will be discussed in detail.The error due to gravity of the perturbation bead has been corrected by averaging the fields in different quadrants.As a result,the unflatness of the electric field is±2.5%,and the dipole field component distributes from 0%to 20%in different longitudinal positions,which indicates the asymmetry of the quadrupole field.The unflatness of the quadrupole field distribution represents a good agreement with the simulation results.High power RF test and beam commissioning of the RFQ are on schedule in early 2014.展开更多
文摘The goal of the present paper is to expand already published works in the frame of"Banded speed cosmology" (BSC). In particular this paper gives validated values for physical quantities not so far investigated in previous publications, i.e., the number of individual physical entity in the universe, as well as the maximum value for acceleration. Validates values mean identical quantities from a numerical point of view obtained with different theoretical procedures, additionally compared with data based on NASA observations with Planck probe.
文摘In this paper, on the basis of the implementation of the national chemical industry standard analytical test methods and analysis of test items, a food additive quality analysis and inspection of network management applications are developed using the development technology of Visual Basic language and computer system operating environment, to achieve a network management software for users on food additives of quality analytical testing. The software sets up an information sharing network platform for enterprise and quality management departments, which is a major innovation in the food additive quality analysis on test management methods and tools.
文摘Astronaut's body mass is an essential factor of health monitoring in space.The latest mass measurement device for the International Space Station (ISS) has employed a linear acceleration method.The principle of this method is that the device generates a constant pulling force,and the astronaut is accelerated on a parallelogram motion guide which rotates at a large radius to achieve a nearly linear trajectory.The acceleration is calculated by regression analysis of the displacement versus time trajectory and the body mass is calculated by using the formula m=F/a.However,in actual flight,the device is instable that the deviation between runs could be 6-7 kg.This paper considers the body non-rigidity as the major cause of error and instability and analyzes the effects of body non-rigidity from different aspects.Body non-rigidity makes the acceleration of the center of mass (C.M.) oscillate and fall behind the point where force is applied.Actual acceleration curves showed that the overall effect of body non-rigidity is an oscillation at about 7 Hz and a deviation of about 25%.To enhance body rigidity,better body restraints were introduced and a prototype based on linear acceleration method was built.Measurement experiment was carried out on ground on an air table.Three human subjects weighing 60-70 kg were measured.The average variance was 0.04 kg and the average measurement error was 0.4%.This study will provide reference for future development of China's own mass measurement device.
基金supported by the National Natural Science Foundation of China(Grant Nos.11079001 and 10905003)the Linear Accelerator Center of PKU-IMPCAS
文摘The 53.667 MHz continuous-wave heavy ion RFQ has been designed and manufactured for the SSC-LINAC project.This four-rod RFQ accelerates ions with maximum mass to charge ratio of 7 from 3.728 keV/u to 143 keV/u.Measurements have been carried out to check the RF performance of the cavity and the quality of the electric field.The S11 of the power coupler is adjusted to better than-44 dB,and the Q0 of the cavity is 6440.The quality of the electric field is evaluated by the perturbation method.The measurement procedure and data analysis will be discussed in detail.The error due to gravity of the perturbation bead has been corrected by averaging the fields in different quadrants.As a result,the unflatness of the electric field is±2.5%,and the dipole field component distributes from 0%to 20%in different longitudinal positions,which indicates the asymmetry of the quadrupole field.The unflatness of the quadrupole field distribution represents a good agreement with the simulation results.High power RF test and beam commissioning of the RFQ are on schedule in early 2014.