Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study. One is the crawlspace warm air heating system and the other is the crawlspace hot water circulation system. Bas...Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study. One is the crawlspace warm air heating system and the other is the crawlspace hot water circulation system. Based on the field study result, by using the simulation sol, ware, THERB, the effectiveness of the crawlspace warm air heating system has been examined. The effect of the factors, such as the wind amount circulating between crawlspace and indoor space, foundation insulation condition, and heat amount into the crawlspace, on the indoor thermal environment has been analyzed. Based on these analyses, the measured crawlspace heating system can make the average temperature of the living room above 20℃. These two houses have excellent thermal environment. According to the simulating result, heat amount input into crawlspace, which can make comfortable indoor thermal environment, for every month in heating period has been roughly concluded, and they are 600 W in December and March and 800 W in February and January, respectively.展开更多
The applicability of cement grout (or cement-based grout) has been considered as an alternative to bentonite grout commonly used to backfill closed-loop vertical ground heat exchangers. In a geothermal heat pump sys...The applicability of cement grout (or cement-based grout) has been considered as an alternative to bentonite grout commonly used to backfill closed-loop vertical ground heat exchangers. In a geothermal heat pump system, repeated heating-cooling cycles may cause adverse effects on the integrity of cement grout in the ground heat exchanger. To account for the temperature cycling effect, the strength degradation of cement grout due to temperature cycling has been examined by measuring the unconfined compression strength of cured specimens in a humidity-temperature controlling chamber with applying temperature cycles between -5℃ and 50℃. There is a tendency that the unconfined compression strength decreases with an increase in the number of temperature cycles. On the other hand, an equivalent hydraulic conductivity of a pipe-embedded cement grout specimen was evaluated by carrying out a modified flexible wall permeameter test equipped with a water circulating system to control temperature inside the pipe section. The applied operating temperature range was from 5 to 35℃. After three cycles of heating-cooling circulation, the equivalent hydraulic conductivity becomes asymptotic to a constant value, which implies there is no severe detachment of the pipe from the cement grout.展开更多
基金Project(10YZ156) supported by Innovation Program of Shanghai Municipal Education Commission, China Project(sdl09009) supported by Training Program for Outstanding Youth Teacher of Shanghai Municipal Education Commission, China Project(Z2010-103) supported by Shanghai Education Development Foundation, China
文摘Two practical crawlspace heating systems introduced in detached houses have been chosen as a field study. One is the crawlspace warm air heating system and the other is the crawlspace hot water circulation system. Based on the field study result, by using the simulation sol, ware, THERB, the effectiveness of the crawlspace warm air heating system has been examined. The effect of the factors, such as the wind amount circulating between crawlspace and indoor space, foundation insulation condition, and heat amount into the crawlspace, on the indoor thermal environment has been analyzed. Based on these analyses, the measured crawlspace heating system can make the average temperature of the living room above 20℃. These two houses have excellent thermal environment. According to the simulating result, heat amount input into crawlspace, which can make comfortable indoor thermal environment, for every month in heating period has been roughly concluded, and they are 600 W in December and March and 800 W in February and January, respectively.
基金supported by the Fundamental Research and Development Program of the Center of New and Renewable Energy of the Ministry of Knowledge and Economy (Grant No. 2008-N-GE08-R-01)the National Research Foundation of Korea Grant funded by the Korean Government (Grant No. 2010-0011159)
文摘The applicability of cement grout (or cement-based grout) has been considered as an alternative to bentonite grout commonly used to backfill closed-loop vertical ground heat exchangers. In a geothermal heat pump system, repeated heating-cooling cycles may cause adverse effects on the integrity of cement grout in the ground heat exchanger. To account for the temperature cycling effect, the strength degradation of cement grout due to temperature cycling has been examined by measuring the unconfined compression strength of cured specimens in a humidity-temperature controlling chamber with applying temperature cycles between -5℃ and 50℃. There is a tendency that the unconfined compression strength decreases with an increase in the number of temperature cycles. On the other hand, an equivalent hydraulic conductivity of a pipe-embedded cement grout specimen was evaluated by carrying out a modified flexible wall permeameter test equipped with a water circulating system to control temperature inside the pipe section. The applied operating temperature range was from 5 to 35℃. After three cycles of heating-cooling circulation, the equivalent hydraulic conductivity becomes asymptotic to a constant value, which implies there is no severe detachment of the pipe from the cement grout.