期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
基于加速应力法的压力传感器泄漏检测 被引量:1
1
作者 夏志鹏 王战生 虞晋凤 《仪表技术与传感器》 CSCD 北大核心 2021年第2期120-122,126,共4页
通过加速泄漏试验,对使用条件下压力传感器基准腔O型密封圈的气密性能进行检验,识别出密封结构存在潜在泄漏故障的产品。通过稳定产品温度、固定观测姿态、控制检测时间等方法改进了测量系统,以精确地检测泄漏结果。在既保证加速效果,... 通过加速泄漏试验,对使用条件下压力传感器基准腔O型密封圈的气密性能进行检验,识别出密封结构存在潜在泄漏故障的产品。通过稳定产品温度、固定观测姿态、控制检测时间等方法改进了测量系统,以精确地检测泄漏结果。在既保证加速效果,又不造成产品损伤的前提下,对压力传感器施加温度、压力激发应力,经过多组温度和压力参数组合的加速泄漏试验,将试验后压力传感器的泄漏量与实际工作中的泄漏量相比较,计算得到加速泄漏试验的加速倍率,确定了压力传感器加速泄漏试验合格判据。通过试验比较,最终选定高温70℃、加压0.3 MPa、保持48 h的试验方案。加速泄漏试验方法可作为压力传感器的寿命试验方法,验证产品的使用期限。 展开更多
关键词 加速泄漏 平面密封 加速倍率 O形密封圈 高温 负压
下载PDF
Comparison of two methods for assessing leakage radiation dose around the head of the medical linear accelerators 被引量:1
2
作者 Ehab M. Attalla 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第9期435-438,共4页
Objective:The aim of this study was to measure the leakage by two methods with ion chamber and ready packs film,and to investigate the feasibility and the advantages of using two dosimetry methods for assessing leakag... Objective:The aim of this study was to measure the leakage by two methods with ion chamber and ready packs film,and to investigate the feasibility and the advantages of using two dosimetry methods for assessing leakage radiation around the head of the linear accelerators.Methods:Measurements were performed using a 30 cm3ion chamber;the gantry at 0°,the X-ray head at 0°,the field size at between the central axis and a plane surface at a FSD of 100 as a reference,a series of concentric circles having radii of 50,75,and 100 cm with their common centre at the reference point.The absorbed dose was measured at the reference point,and this would be used as the reference dose.With the diaphragm closed,the measurements were taken along the circumference of the three circles and at 45°intervals.Results:Leakage radiations while the treatment head was in the vertical position varied between 0.016%–0.04%.With the head lying horizontally,leakage radiation was the same order magnitude and varied between 0.02%–0.07%.In the second method,the verification was accomplished by closing the collimator jaws and covering the head of the treatment unit with the ready pack films.The films were marked to permit the determination of their positions on the machine after exposed and processed.With the diaphragm closed,and the ready packs films around the linear accelerator the beam turned on for 2500 cGy(2500 MU).The optical density of these films was measured and compared with this of the reference dose.Leakage radiation varied according to the film positions and the magnitude of leakage was between 0.005%–0.075%.Conclusion:The differences between the values of the leakage radiation levels observed at different measurement points do not only reflect differences in the effective shielding thickness of the head wall,but are also related to differences in the distances between the target and the measurement points.The experimental errors involved in dosimetric measurement also contribute to such differences. 展开更多
关键词 leakage radiation acceptance testing linear accelerator ion chamber ready packs film
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部