Ship-mounted container cranes are challenging industrial applications of nonlinear pendulum-like systems with oscillating disturbance which can cause them unstable.Since wave-induced ship motion causes the hoisted con...Ship-mounted container cranes are challenging industrial applications of nonlinear pendulum-like systems with oscillating disturbance which can cause them unstable.Since wave-induced ship motion causes the hoisted container to swing during the transfer operation,the swing motion may be dangerously large and the operation must be stopped.In order to reduce payload pendulation of ship-mounted crane,nonlinear dynamics of ship-mounted crane is derived and a control method using T-S fuzzy model is proposed.Simulation results are given to illustrate the validity of the proposed design method and pendulation of ship-mounted crane is reduced significantly.展开更多
The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophagea...The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophageal function is normally evaluated by means of manometry even though it reflects the squeeze force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe with combined axial force and manometry recordings showed that axial force amplitude increased by 130% in contrast to an increase of 30% using manometry. Using axial force in combination with manometry provides a more complete picture of esophageal motility, and the current paper outlines the advantages of using this method.展开更多
Purpose: The aim of this study was to assess the effects of combining the FIFA 11+ and acute vibration training on reactive strength index (RSI) and 505 agility. Methods: Seventy-four male collegiate soccer playe...Purpose: The aim of this study was to assess the effects of combining the FIFA 11+ and acute vibration training on reactive strength index (RSI) and 505 agility. Methods: Seventy-four male collegiate soccer players took part in the study and were randomly assigned to FIFA 11+ with acute vibration group (FIFA + WBV), FIFA 11+ with isometric squat group (FIFA + IS) or a control group consisting of the F1FA 11+ alone (Con). The warm-up consisted of the FIFA 11+ and was administered to all participants. The participants in the acute vibration group were exposed to 30 s whole body vibration in squat position immediately post warm-up. The isometric group completed an isometric squat for 30 s immediately post warm-up. Results: RSI significantly improved pre- to post-intervention amongst FIFA + WBV (p 〈 0.001) due to a decrease in contact time (p 〈 0.001) in comparison to FIFA + IS and Con, but 505 agility was not affected. Conclusion: The results of this study suggest the inclusion of an acute bout of WBV post FIFA 11+ warm-up produces a neuromuscular response leading to an improvement in RSI. Future research is required to examine the exact mechanisms behind these improvements amongst other populations and over time course of the performance.展开更多
基金work supported by Changwon National University in 2011-2012work partly supported by the second stage of Brain Korea 21 Projects
文摘Ship-mounted container cranes are challenging industrial applications of nonlinear pendulum-like systems with oscillating disturbance which can cause them unstable.Since wave-induced ship motion causes the hoisted container to swing during the transfer operation,the swing motion may be dangerously large and the operation must be stopped.In order to reduce payload pendulation of ship-mounted crane,nonlinear dynamics of ship-mounted crane is derived and a control method using T-S fuzzy model is proposed.Simulation results are given to illustrate the validity of the proposed design method and pendulation of ship-mounted crane is reduced significantly.
基金Supported by Det Obelske Familiefond and Spar Nord Fonden
文摘The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophageal function is normally evaluated by means of manometry even though it reflects the squeeze force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external force transducers over in-vivo strain gauges of various sizes to electrical impedance based measurements. The amplitude and duration of the axial force has been shown to be as reliable as manometry. Normal, as well as abnormal, manometric recordings occur with normal bolus transit, which have been documented using imaging modalities such as radiography and scintigraphy. This inconsistency using manometry has also been documented by axial force recordings. This underlines the lack of information when diagnostics are based on manometry alone. Increasing the volume of a bag mounted on a probe with combined axial force and manometry recordings showed that axial force amplitude increased by 130% in contrast to an increase of 30% using manometry. Using axial force in combination with manometry provides a more complete picture of esophageal motility, and the current paper outlines the advantages of using this method.
文摘Purpose: The aim of this study was to assess the effects of combining the FIFA 11+ and acute vibration training on reactive strength index (RSI) and 505 agility. Methods: Seventy-four male collegiate soccer players took part in the study and were randomly assigned to FIFA 11+ with acute vibration group (FIFA + WBV), FIFA 11+ with isometric squat group (FIFA + IS) or a control group consisting of the F1FA 11+ alone (Con). The warm-up consisted of the FIFA 11+ and was administered to all participants. The participants in the acute vibration group were exposed to 30 s whole body vibration in squat position immediately post warm-up. The isometric group completed an isometric squat for 30 s immediately post warm-up. Results: RSI significantly improved pre- to post-intervention amongst FIFA + WBV (p 〈 0.001) due to a decrease in contact time (p 〈 0.001) in comparison to FIFA + IS and Con, but 505 agility was not affected. Conclusion: The results of this study suggest the inclusion of an acute bout of WBV post FIFA 11+ warm-up produces a neuromuscular response leading to an improvement in RSI. Future research is required to examine the exact mechanisms behind these improvements amongst other populations and over time course of the performance.