某地铁车辆段自动化立体仓库自动喷水设计
1
作者 付长军 袁登峰 范学良 《中文科技期刊数据库(全文版)工程技术》 2024年第7期0118-0121,共4页
随着地铁管理精细化要求及城市用地日益紧张,自动化立体物资总库逐渐在地铁车辆段得到了广泛的使用。针对立体仓库特有的建筑特点,建议采用自动喷水灭火系统为主的消防给水。本文研究了两种自动喷水系统的设计形式,并从系统可靠性、设... 随着地铁管理精细化要求及城市用地日益紧张,自动化立体物资总库逐渐在地铁车辆段得到了广泛的使用。针对立体仓库特有的建筑特点,建议采用自动喷水灭火系统为主的消防给水。本文研究了两种自动喷水系统的设计形式,并从系统可靠性、设计参数、系统特点等方面进行比较,说明在地铁车辆段自动化立体仓库采用大空间智能喷水灭火系统的优越性和先进性。 展开更多
关键词 化立体物资总库 地铁车辆段 动喷水灭火系统 大空间智能喷水灭火系统
下载PDF
Heat resistance and water protection effectiveness for large single-pane fireproof glass
2
作者 邵荃 李芳 +1 位作者 陈涛 孙占辉 《Journal of Central South University》 SCIE EI CAS 2011年第6期2185-2191,共7页
The effects and heat transfer mode of water film and sprinkler system on the heat-resistant property associated with the insulation of a fireproof glass were investigated. In the experiments, fireproof glass with a si... The effects and heat transfer mode of water film and sprinkler system on the heat-resistant property associated with the insulation of a fireproof glass were investigated. In the experiments, fireproof glass with a size of 3 300 mm (height)×2 200 mm (width) ×12 mm (thickness) was exposed to an oil pool fire with a power of approximately 1.4 MW. The experimental results show that the application of the water film or sprinkler system on the glass can effectively resist the intensive heat from the fire in the test due to the absorption of latent heat. The permitted period of integrity and insulation with a water film and a sprinkler system could be extended to 60 min. It should be noted that the temperature of the glass surface Can be kept under 60℃in a 60 min test. The experimental results suggest that it is feasible to substitute fireproof glass with water film for a fireproof door as long as the water film or sprinkler system can work stably and water can cover the whole surface of the frreproof glass. 展开更多
关键词 water film sprinkler system HEAT-RESISTANCE fireproof glass fire test
下载PDF
Structure Design of Large-scale Sow House with Fermentation Bed
3
作者 Bo LIU Zhaolong LI +4 位作者 Jianglin LAN Qinlou HUANG Jianyang TANG Wenquan YU Huai SHI 《Agricultural Science & Technology》 CAS 2014年第10期1819-1825,共7页
ln this research, the whole contact-type large-scale sow house with fer-mentation bed was designed. The planning area of the entire piggery was 5 700 m2 with workplace and green belts. The sow house was 93 m long and ... ln this research, the whole contact-type large-scale sow house with fer-mentation bed was designed. The planning area of the entire piggery was 5 700 m2 with workplace and green belts. The sow house was 93 m long and 33 m wide, a total of 3 069 m2, including office area of 60 m2 and aisle area of 107 m2. The fer-mentation bed had an area of 2 902 m2 with length of 88.7 m and width of 27.7 m. lts area accounted for 95% of the total area of sow house. The fermentation mattress had a depth of 80 cm, and had a volume of 2 321 m3, equivalent to 733 t of coconut chaff and rice chaff. On a large fermentation bed, the areas for boars, replacement gilts, pregnant sows, obstetric tables, nursery pigs, etc. were designed. The large-scale sow house with fermentation bed was equipped with the automatic feeding system, automatic sprinkler system, automatic positioning column for preg-nant sows, sows' obstetric table system, fanning wet curtain cooling system, video monitoring system, environmental monitoring (light, temperature, water, humidity, CO2, NH3) and automatic control system. Every farming area was equipped with feeding trough and water trough. The water though was fixed with overflow pipe for removing the extra water. The house could hold 500-head sows. Each sow occu-pied 4.9 m2 of the fermentation bed in average. The designed sow house had a maximum annual output of 10 000 piglets. 展开更多
关键词 Fermentation bed Large-scale sow house Whole contact-type fermen-tation-bed obstetric table Automatic control Non-pollution No smelL