双馈风力发电系统故障穿越性能改善的控制策略 被引量:6
1
作者 高仕红 《可再生能源》 CAS 北大核心 2016年第6期828-836,共9页
PI控制策略限制了双馈风力发电系统的故障穿越能力。文章提出一种基于多开关控制的故障穿越策略,在机端电压跌落瞬态期间利用多态滞环电流矢量控制器快速的瞬态性能抑制转子绕组的过电流,同时实施转子绕组串联动态电阻器,进一步抑制转... PI控制策略限制了双馈风力发电系统的故障穿越能力。文章提出一种基于多开关控制的故障穿越策略,在机端电压跌落瞬态期间利用多态滞环电流矢量控制器快速的瞬态性能抑制转子绕组的过电流,同时实施转子绕组串联动态电阻器,进一步抑制转子绕组的过电压和过电流。详细介绍了多态滞环电流矢量控制器和基于多开关控制的故障穿越策略的实施过程。针对3种典型机端电压跌落类型,在Matlab/Simu1ink平台中构建了所提出的故障穿越控制策略的动态仿真模型并验证了其可行性。仿真结果表明,所提出的故障穿越控制策略改善了双馈风力发电机系统的故障穿越性能。 展开更多
关键词 双馈风力发电系统 故障穿越策略 多开关控制 多态滞环电流矢量控制 动态电阻器
下载PDF
Analysis of the Correlation between the Level of Contact Degradation and the Dynamic Resistance Curve in Circuit Breakers 被引量:2
2
作者 Ronimack Trajano de Souza Edson Guedes da Costa 《Journal of Energy and Power Engineering》 2014年第6期1104-1111,共8页
The DRM (dynamic contact resistance measurement) in high voltage circuit breakers is a manner of evaluating the internal ageing condition of the chamber. DRM is similar to static contact resistance measurement testi... The DRM (dynamic contact resistance measurement) in high voltage circuit breakers is a manner of evaluating the internal ageing condition of the chamber. DRM is similar to static contact resistance measurement testing, but instead of measuring a single value when the breaker contacts are closed (static value), the ohmic resistance is measured at various contact positions, from the beginning of the contact opening until a complete separation of the contacts. The relationship between the contact resistances of the new circuit breaker and the ageing circuit breaker in operation provides subsidy for the evaluation of both the main and arcing contact conditions. This research aims to analyze the correlation between the various levels of degradation of the contacts and the configuration of the DRM curve. This work considers curve samples from new acceleration tests. breaker chamber contacts and different levels of degradation by 展开更多
关键词 DRM (dynamic contact resistance measurement) circuit breaker dynamic resistance contact resistance resistance curve.
下载PDF
Investigation of Interline Dynamic Voltage Restorer with Virtual Impedance Injection
3
作者 Ahmed Elserougi Ahmed Hossam-Eldin +1 位作者 Ahmed Massoud Shehab Ahmed 《Journal of Energy and Power Engineering》 2012年第1期101-109,共9页
The inter-line dynamic voltage restorer (IDVR) consists of several voltage source inverters connected to different independent distribution feeders with common dc bus. When one of the inverters compensates for volta... The inter-line dynamic voltage restorer (IDVR) consists of several voltage source inverters connected to different independent distribution feeders with common dc bus. When one of the inverters compensates for voltage sag that appears in its feeder (voltage control mode), the other inverters pump the required power into the dc bus (power control mode). Each inverter will have both voltage and power controllers; only one controller is in use during the abnormal conditions according to its feeder state. The voltage controller uses one of the dynamic voltage restoration techniques. In this paper, the in-phase technique is applied and two types of loads are considered (constant impedance and three phase induction motor). Since the voltage restoration process may need real power injection into the distribution system, the power controller injects this power via voltage injection. This voltage injection is simulated by voltage drop across series virtual impedance. A new scheme is proposed to select the impedance value. The impedance value is selected such that the power consumed by this impedance represents the required power to be transferred without perturbing the load voltage. The performance of this system is also studied during voltage swell. A scheme for operation of multi-feeder IDVR system is proposed in this paper. Simulation results substantiate the proposed concept. 展开更多
关键词 Dynamic voltage restorers IDVR voltage sag voltage swell power quality.