Aiming at localizing the telemetric capsule for detecting gastrointestinal physiological parameters in vivo accurately,a portable alternating current(AC)electromagnetic localization system is designed.To verify the fe...Aiming at localizing the telemetric capsule for detecting gastrointestinal physiological parameters in vivo accurately,a portable alternating current(AC)electromagnetic localization system is designed.To verify the feasibility of the method,the model and construction of the localization system are detailed.And static and dynamic accuracy of the localization system are tested by experiments.Next,we compare the simulating results of the electromagnetic radiation aroused by the localization system with the electromagnetic safety standards of human(ICNIRP guidelines and IEEE standard C95.1-1991).Finally,in terms of the results of the static and dynamic experiments,conclusions are drawn that the accuracy of portable positioning system is high(less than 10 mm)enough to satisfy the localization need of the micro invasive medical devices in vivo,and there is no harm of electromagnetic radiation to human.展开更多
This paper presents suggestions in aspects(which should meet the standards) such as alarm indication, system setup and system security during the designing process of alarm system in medical electrical equipment, whic...This paper presents suggestions in aspects(which should meet the standards) such as alarm indication, system setup and system security during the designing process of alarm system in medical electrical equipment, which can be used as a reference for manufacturers.展开更多
基金National Natural Science Foundation of China(NSFC)(No.30570485)National High Technology Research and Development Program of China(863)(No.2006AA04Z368)Natural Science Foundation of Shanghai,China(No.06ER1406)
文摘Aiming at localizing the telemetric capsule for detecting gastrointestinal physiological parameters in vivo accurately,a portable alternating current(AC)electromagnetic localization system is designed.To verify the feasibility of the method,the model and construction of the localization system are detailed.And static and dynamic accuracy of the localization system are tested by experiments.Next,we compare the simulating results of the electromagnetic radiation aroused by the localization system with the electromagnetic safety standards of human(ICNIRP guidelines and IEEE standard C95.1-1991).Finally,in terms of the results of the static and dynamic experiments,conclusions are drawn that the accuracy of portable positioning system is high(less than 10 mm)enough to satisfy the localization need of the micro invasive medical devices in vivo,and there is no harm of electromagnetic radiation to human.
文摘This paper presents suggestions in aspects(which should meet the standards) such as alarm indication, system setup and system security during the designing process of alarm system in medical electrical equipment, which can be used as a reference for manufacturers.