提出了一种张量人工阻抗单元的表面阻抗分析计算方法,主要对矩形形状单元的表面阻抗开展了研究。通过仿真软件Ansys-HFSS提取了人工阻抗单元表面的入射散射场,再利用等效传输线技术计算出表面的张量阻抗。利用张量阻抗与表面场的关系,...提出了一种张量人工阻抗单元的表面阻抗分析计算方法,主要对矩形形状单元的表面阻抗开展了研究。通过仿真软件Ansys-HFSS提取了人工阻抗单元表面的入射散射场,再利用等效传输线技术计算出表面的张量阻抗。利用张量阻抗与表面场的关系,给出了人工阻抗单元的标量阻抗与传播方向的关系,验证了计算的准确性。最后作为实例,设计了一种基于张量阻抗单元的圆极化全息天线,天线具有较好的圆极化特性,增益大于21 d B。展开更多
A bandwidth-enhanced dual-polarized antenna is proposed for 2/3/4/5G applications,which is composed of distributed parasitic elements(DPEs),a main radiator,two improved broadband integrated baluns and a reflector.Firs...A bandwidth-enhanced dual-polarized antenna is proposed for 2/3/4/5G applications,which is composed of distributed parasitic elements(DPEs),a main radiator,two improved broadband integrated baluns and a reflector.First,a novel tooth-shape shorted slot line in the improved broadband integrated balun is analyzed to adjust the input impedance of the antenna.Then,DPEs with 2×2 circular plates loading over the main radiator are proposed to improve broadband impedance matching and radiation pattern.By utilizing impedance compensation of the tooth-shaped shorted slot line and the electromagnetic induction of the DPEs,the antenna achieves an enhanced impedance bandwidth and a stable radiation pattern.To verify these ideas,the bandwidth-enhanced dual-polarized antenna was fabricated and measured.The experimental results indicate that the proposed antenna achieves an operating bandwidth of 72.2%(1.69 to 3.60 GHz)with a return loss(RL)less than-15 dB and a port-to-port isolation(ISO)larger than 30 dB.The antenna obtains a half-power beamwidth(HPBW)within(66±5)°and a gain within(9.0±0.6)dBi in the 2/3/4G bands,and an HPBW within(61.5±2.5)°and a gain within(9.8±0.3)dBi in the 5G band.Across the whole band,the cross-polarization discrimination(XPD)and the front-to-back ratio are both larger than 20 dB.展开更多
An online TL (transmission line) impedance TPIS (transmission line parameter identification system) using PMU (phasor measurement unit) was recently developed and implemented at CSG (china southern power grid c...An online TL (transmission line) impedance TPIS (transmission line parameter identification system) using PMU (phasor measurement unit) was recently developed and implemented at CSG (china southern power grid company), Traditional approaches for TL impedance calculation only approximate the effect of conductor sags and ignore the dependence of impedances on temperature variation. Utilizing PMU measurements may improve the accuracy of TL parameters calculation. The challenge is that the parameters identified are very sensitive to noise and errors in PMU measurements, which are difficult to quantify and can be uncertain under different system operating/loading condition, TPIS provides an innovative yet practical problem formulation for TL sequence parameter estimation based on least-squares with linear constraints. A bootstrapping-based resampling technique is developed and a new metric is proposed to determine the credibility of the estimated sequence impedances. This paper discusses the proposed methodologies, challenges, as well as implementation issues identified during the development of TPIS.展开更多
文摘提出了一种张量人工阻抗单元的表面阻抗分析计算方法,主要对矩形形状单元的表面阻抗开展了研究。通过仿真软件Ansys-HFSS提取了人工阻抗单元表面的入射散射场,再利用等效传输线技术计算出表面的张量阻抗。利用张量阻抗与表面场的关系,给出了人工阻抗单元的标量阻抗与传播方向的关系,验证了计算的准确性。最后作为实例,设计了一种基于张量阻抗单元的圆极化全息天线,天线具有较好的圆极化特性,增益大于21 d B。
基金The National Natural Science Foundation of China(No.61471117).
文摘A bandwidth-enhanced dual-polarized antenna is proposed for 2/3/4/5G applications,which is composed of distributed parasitic elements(DPEs),a main radiator,two improved broadband integrated baluns and a reflector.First,a novel tooth-shape shorted slot line in the improved broadband integrated balun is analyzed to adjust the input impedance of the antenna.Then,DPEs with 2×2 circular plates loading over the main radiator are proposed to improve broadband impedance matching and radiation pattern.By utilizing impedance compensation of the tooth-shaped shorted slot line and the electromagnetic induction of the DPEs,the antenna achieves an enhanced impedance bandwidth and a stable radiation pattern.To verify these ideas,the bandwidth-enhanced dual-polarized antenna was fabricated and measured.The experimental results indicate that the proposed antenna achieves an operating bandwidth of 72.2%(1.69 to 3.60 GHz)with a return loss(RL)less than-15 dB and a port-to-port isolation(ISO)larger than 30 dB.The antenna obtains a half-power beamwidth(HPBW)within(66±5)°and a gain within(9.0±0.6)dBi in the 2/3/4G bands,and an HPBW within(61.5±2.5)°and a gain within(9.8±0.3)dBi in the 5G band.Across the whole band,the cross-polarization discrimination(XPD)and the front-to-back ratio are both larger than 20 dB.
文摘An online TL (transmission line) impedance TPIS (transmission line parameter identification system) using PMU (phasor measurement unit) was recently developed and implemented at CSG (china southern power grid company), Traditional approaches for TL impedance calculation only approximate the effect of conductor sags and ignore the dependence of impedances on temperature variation. Utilizing PMU measurements may improve the accuracy of TL parameters calculation. The challenge is that the parameters identified are very sensitive to noise and errors in PMU measurements, which are difficult to quantify and can be uncertain under different system operating/loading condition, TPIS provides an innovative yet practical problem formulation for TL sequence parameter estimation based on least-squares with linear constraints. A bootstrapping-based resampling technique is developed and a new metric is proposed to determine the credibility of the estimated sequence impedances. This paper discusses the proposed methodologies, challenges, as well as implementation issues identified during the development of TPIS.