A solution cooling absorption(SCA)approach is proposed to modify the aqueous ammonia absorption refrigerat-ion cycle using the strong solution from the absorber to cool the forepart of the absorption in the cycle fo...A solution cooling absorption(SCA)approach is proposed to modify the aqueous ammonia absorption refrigerat-ion cycle using the strong solution from the absorber to cool the forepart of the absorption in the cycle for reclaiming some portion of absorption heat.As a consequence of raised temperature at the inlet,the strong solution partially boils at the outlet of the solution heat exchanger,and diminishes the thermal heat consumption of the heat source.The calculation results show that the coefficient of performance(COP)of this modified cycle is about 28.3% higher than that of the traditional cycle under typical conditions;while the required heat transfer area of the total heat exchangers of the cycle is somewhat less than that of the traditional one.The capacity of refrigeration with the new absorption cycle is more than doubled in contrast to the adsorption scheme with an identical configuration.It is sufficient to supply a fishing boat the chilling capacity for preservation of fishing products with the modified cycle chiller driven by its diesel engine exhaust.展开更多
Allylpolyethoxy carboxylate macromonomers possessing polyethylene oxygen long chains were synthesized by advanced technology of the polyether cap.A novel double-hydrophilic block copolymer was prepared through free ra...Allylpolyethoxy carboxylate macromonomers possessing polyethylene oxygen long chains were synthesized by advanced technology of the polyether cap.A novel double-hydrophilic block copolymer was prepared through free radical polymeric reactions in aqueous solution and its performance on CaCO3 inhibition and dispersancy activity towards Fe2 O3 was evaluated in recirculating cooling water systems.The study shows that acrylic acid-allylpolyethoxy carboxylate has a significant ability to inhibit the precipitation of calcium carbonate and an excellent dispersing capability to stabilize iron Ⅲ in industrial cooling systems. X-ray diffraction shows that there is a number of vaterite crystals in the presence of the phosphorous free and non-nitrogen copolymer. The change in crystal forms is also confirmed by the Fourier-transform infrared spectra the scanning electron microscopy and the transmission electron microscopy. The inhibition mechanism is proposed and it shows that the interactions between calcium and polyethylene glycol PEG are the fundamental impetus for restraining the formation of the scale in cooling water systems.展开更多
Fouling of heat transfer surfaces during subcooled flow boiling is a frequent engineering problem in process industries. It has been generally observed that the deposits in such industrial systems consist mainly of ca...Fouling of heat transfer surfaces during subcooled flow boiling is a frequent engineering problem in process industries. It has been generally observed that the deposits in such industrial systems consist mainly of calcium carbonate (CaCO3), which has inverse solubility characteristics. This investigation focused on the mechanism to control deposition and the morphology of crystalline deposits. A series of experiments were carried out at different surface and bulk temperatures, fluid velocities and salt ion concentrations. It is shown that the deposition rate is controlled by different mechanism in the range of experimental parameters, depending on salt ion concentration. At higher ion concentration, the fouling rate increases linearly with surface temperature and the effect of flow velocity on deposition rate is quite strong, suggesting that mass diffusion controls the fouling process. On the contrary, at lower ion concentration, the fouling rate increases exponentially with surface temperature and is independent of the velocity, illustrating that surface reaction controls the fouling process. By analysis of the morphology of scale, two types of crystal (calcite and aragonite) are formed. The lower the temperature and ion concentration, the longer the induction period and the higher the percentage of calcite nreciDitated.展开更多
The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation ...The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation model of water source chiller plant established in dynamic transient simulation program (TRNSYS),the four-variable quadratic orthogonal regression experiments were carried out by taking cooling load,cooling water supply temperature,cooling water flow rate and chilled water flow rate as variables,and the fitting formulas expressing the relationships between the total energy consumption of chiller plant with the four selected parameters was obtained. With the SAS statistical software and MATHEMATICA mathematical software,the optimal chilled water flow rate and cooling water flow rate which result in the minimum total energy consumption were determined under continuously varying cooling load and cooling water supply temperature. With regard to a chiller plant serving an office building in Shanghai,the total energy consumptions under different control strategies were computed in terms of the forecasting function of cooling load and water source temperature. The results show that applying the optimal control strategy to the chiller plant can bring a saving of 23.27% in power compared with the corresponding conventional variable speed plant,indicating that the optimal control strategy can improve the energy efficiency of chiller plant.展开更多
Weight lost method was used to comparatively study the corrosion behavior of four different metals under the dosage of chlorine dioxide, chlorine and their mixture respectively. The experimental results indicated that...Weight lost method was used to comparatively study the corrosion behavior of four different metals under the dosage of chlorine dioxide, chlorine and their mixture respectively. The experimental results indicated that chlorine causes the most serious corrosion of carbon steel, and the higher the concentration of chlorine, the more serious the corrosion. On the contrary, metals corrosion is the least serious in the case of chlorine dioxide. The results further revealed that chlorine dioxide is the most effective water treatment reagent, making it the best choice to use extensively in circulated cooling water disinfection and corrosion control.展开更多
A series of orthogonal array experiments were conducted using carbon source, ammonia nitrogen and total phosphorus (TP) as major influencing factors to investigate the effects of nutrients on biofouling formation an...A series of orthogonal array experiments were conducted using carbon source, ammonia nitrogen and total phosphorus (TP) as major influencing factors to investigate the effects of nutrients on biofouling formation and preponderant bacteria diversity in the recirculatiug cooling water system. Carbon source was demonstrated to be the most significant determinant affecting the biofouling formation. A minimum biofouling outcome was obtained when BOD2, NHa+-N and TP were 25, 10, and 1 mg/L, respectively. Then the preponderant bacteria strains in biofouling mass under two typical culture conditions (negative and favorable) were identified applying both traditional biochemical methods and further molecular biology technology with phylogenetic affiliation analysis, which indicated that Enterobacteriaceae Enterobacter, Micrococcaceae Staphylococcus, Bacillaceae Bacillus, Enterobacteriaceae Proteus, Neisseriaceae Neisseria and Pseudomonadaceae Pseudomonas were dominant under negative condition, while Enterobacteriaceae Klebsiella, Enterobacteriaceae Enterobacter and Microbacterium - under favorable one.展开更多
Low critical temperature limits the application of CO_2 trans-critical power cycle.The binary mixture of R290/CO_2has higher critical temperature.Using mixture fluid may solve the problem that subcritical CO_2 is hard...Low critical temperature limits the application of CO_2 trans-critical power cycle.The binary mixture of R290/CO_2has higher critical temperature.Using mixture fluid may solve the problem that subcritical CO_2 is hardly condensed by conventional cooling water.In this article,theoretical analysis is executed to study the performance of the zeotropic mixture for trans-critical power cycle using low-grade liquid heat source with temperature of200℃.The results indicated that the problem that CO_2 can't be condensed in power cycle by conventional cooling water can be solved by mixing R290 to CO_2.Variation trend of outlet temperature of thermal oil in supercritical heater with heating pressure is determined by the composition of the mixture fluid.Gliding temperature causes the maximum outlet temperature of cooling water with the increase of mass fraction of R290.There are the maximum values for cycle thermal efficiency and net power output with the increase of supercritical heating pressure.展开更多
Mesoporous SiO_2 microspheres were synthesized using the sol-gel method and were characterized by TEM, FT-IR and BET techniques. The diameter of the microspheres is about 100—150 nm, and the average mesopore diameter...Mesoporous SiO_2 microspheres were synthesized using the sol-gel method and were characterized by TEM, FT-IR and BET techniques. The diameter of the microspheres is about 100—150 nm, and the average mesopore diameter is 2.55 nm, while the specific surface area is 1 088.9 m2/g. Mesoporous SiO_2 microspheres adsorb glutaraldehyde and immobilize laccase by means of the aldehyde group in glutaral which can react with the amidogen of laccase. The immobilization conditions were optimized at a glutaraldehyde concentration of 0.75%, a crosslinking time of 8 h, a laccase concentration of 0.04 L/L and an immobilization time of 10 h. When diesel leakage concentration was 80 mg/L, the highest corrosion inhibition efficiency of immobilized laccase reached 49.23%, which was slightly lower than the corrosion inhibition efficiency of free laccase(59%). The diesel degradation ratio could reach up to 45%. It has been proved that the immobilized laccase could degrade diesel to inhibit corrosion.展开更多
We deployed two ADCP mooring systems west of the Luzon Strait in August 2008,and measured the upper ocean currents at high frequency.Two typhoons passed over the moorings during approximately one-month observation per...We deployed two ADCP mooring systems west of the Luzon Strait in August 2008,and measured the upper ocean currents at high frequency.Two typhoons passed over the moorings during approximately one-month observation period.Using ADCP observations,satellite wind and heat flux measurements,and high-resolution model assimilation products,we studied the response of the upper ocean to typhoons.The first typhoon,Nuri,passed over one of the moorings,resulting in strong Ekman divergence and significant surface cooling.The cooling of surface water lagged the typhoon wind forcing about one day and lasted about five days.The second typhoon,Sinlaku,moved northward east of the Luzon Strait,and did not directly impact currents near the observation regions.Sinlaku increased anomalous surface water transport exchange across the Luzon Strait,which modulated the surface layer current of the Kuroshio.展开更多
Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipmen...Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.展开更多
The aim of this paper is to collect information about dairy cow's behaviour connected to different environmental conditions. During summer 2009 and winter 2010 experimental trials were arranged to verify the behaviou...The aim of this paper is to collect information about dairy cow's behaviour connected to different environmental conditions. During summer 2009 and winter 2010 experimental trials were arranged to verify the behaviour of dairy cows in a farm located in Po Plain (Italy). The barn was provided with an air-water cooling system, based on the use of fans and sprinklers placed only in the feeding alley. Two different trials were carried out. The first experiment was targeted on verifying the use of the cubicles by the cows in relation to the availability of the cooling system only in feeding area. The second trial aimed at testing the effectiveness of zone cooling systems placed in the front of cubicles. For this purpose three cubicles in the barn were provided with cooling systems, based on the input of high velocity conditioned air streams. The results clearly remark that the behaviour of the animals is greatly influenced by the environmental conditions. With high temperatures the use of the cubicles is deeply reduced and the animals prefer to stay in feeding area, thus benefiting from the cooling effect of water sprinkled by the showers and of the air streams created by the fans. With air temperatures increasing from 21℃ to 33 ℃ the cows reduce the staying in the cubicles, which gets down from 540 to 32% (r2 = 0.2608). As regards the efficacy of zone cooling system in the cubicles, the results are not particularly encouraging. The cows continue to use the cubicles without changing the behaviour in relation to the presence of conditioned air flow.展开更多
The wastewater discharged from the 1.0 Mt/a ethylene unit at Maoming Petrochemical Company was separated according to its quality, and a major part ofwastewater with better quality was properly treated via the process...The wastewater discharged from the 1.0 Mt/a ethylene unit at Maoming Petrochemical Company was separated according to its quality, and a major part ofwastewater with better quality was properly treated via the process of"IRABF + high-efficiency fiber filtering + disinfection" to make the wastewater quality comply with the quality of recycled cooling water, so that the technique for reused petrochemical wastewater was more reliable technically and more reasonable economically,展开更多
An experimental investigation of natural gas hydrate formation has been conducted in a high-pressure water spraying reactor,which is cooled by the circulation water through an external cooling jacket.The results show ...An experimental investigation of natural gas hydrate formation has been conducted in a high-pressure water spraying reactor,which is cooled by the circulation water through an external cooling jacket.The results show that the morphology of hydrates formed by water spraying is like ice-slurry,which depends on the initial pressure and temperature.At a certain reaction pressure,the rate of hydrate formation is increasing with lower temperature.And also,the induction time of hydrate formation can be greatly shortened by water spraying compared to a quiescent system.Solution with appropriate surfactant sodium dodecyl sulfate (SDS) is found to improve the formation rate obviously.展开更多
An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the no...An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the novel cycle based on promising parallel flow with cooling capacity of 1 150 kW is carried out under various heat recovery generator vapor production ratios ranging from 0 to 3.5%. The life cycle saving economic analysis, for which the annual gas conservation is estimated with Bin method, is employed to prove the worthiness of extra expenditure. Results show that the optimum gas saving revenue is obtained at 2.8% heat recovery generator vapor production ratio with 42 kW exhaust heat recovered, and the system energy efficiency is improved from 1.78 to 1.83. The initial investment of exchanger can be paid back within 7 years and 9 000 CNY of gas saving revenue will be achieved over the 15-year life cycle of the machine. This technology can be easily implemented and present desirable economic effects, which is feasible to the development of triple-effect absorption cycles.展开更多
基金The National Natural Science Foundation of China(No.50776016)the National Key Technology R&D Program of China during the 11th Five-Year Plan Period(No.2008BAJ12B02)
文摘A solution cooling absorption(SCA)approach is proposed to modify the aqueous ammonia absorption refrigerat-ion cycle using the strong solution from the absorber to cool the forepart of the absorption in the cycle for reclaiming some portion of absorption heat.As a consequence of raised temperature at the inlet,the strong solution partially boils at the outlet of the solution heat exchanger,and diminishes the thermal heat consumption of the heat source.The calculation results show that the coefficient of performance(COP)of this modified cycle is about 28.3% higher than that of the traditional cycle under typical conditions;while the required heat transfer area of the total heat exchangers of the cycle is somewhat less than that of the traditional one.The capacity of refrigeration with the new absorption cycle is more than doubled in contrast to the adsorption scheme with an identical configuration.It is sufficient to supply a fishing boat the chilling capacity for preservation of fishing products with the modified cycle chiller driven by its diesel engine exhaust.
基金The National Natural Science Foundation of China(No.51077013)China Postdoctoral Science Foundation(No.2014M560381)+3 种基金Jiangsu Planned Projects for Postdoctoral Research Funds(No.1401033B)Transformation Program of Science and Technology Achievements of Jiangsu Province(No.BA2011086)the 333High-Level Talents Training Project of Jiangsu Province(No.BRA2010033)the Project of Young Scientist Foundation of Nanjing Xiaozhuang University(No.2013NXY89)
文摘Allylpolyethoxy carboxylate macromonomers possessing polyethylene oxygen long chains were synthesized by advanced technology of the polyether cap.A novel double-hydrophilic block copolymer was prepared through free radical polymeric reactions in aqueous solution and its performance on CaCO3 inhibition and dispersancy activity towards Fe2 O3 was evaluated in recirculating cooling water systems.The study shows that acrylic acid-allylpolyethoxy carboxylate has a significant ability to inhibit the precipitation of calcium carbonate and an excellent dispersing capability to stabilize iron Ⅲ in industrial cooling systems. X-ray diffraction shows that there is a number of vaterite crystals in the presence of the phosphorous free and non-nitrogen copolymer. The change in crystal forms is also confirmed by the Fourier-transform infrared spectra the scanning electron microscopy and the transmission electron microscopy. The inhibition mechanism is proposed and it shows that the interactions between calcium and polyethylene glycol PEG are the fundamental impetus for restraining the formation of the scale in cooling water systems.
基金Supported by the Special Funds for Major State Basic Research Projects of China (G2000026304)
文摘Fouling of heat transfer surfaces during subcooled flow boiling is a frequent engineering problem in process industries. It has been generally observed that the deposits in such industrial systems consist mainly of calcium carbonate (CaCO3), which has inverse solubility characteristics. This investigation focused on the mechanism to control deposition and the morphology of crystalline deposits. A series of experiments were carried out at different surface and bulk temperatures, fluid velocities and salt ion concentrations. It is shown that the deposition rate is controlled by different mechanism in the range of experimental parameters, depending on salt ion concentration. At higher ion concentration, the fouling rate increases linearly with surface temperature and the effect of flow velocity on deposition rate is quite strong, suggesting that mass diffusion controls the fouling process. On the contrary, at lower ion concentration, the fouling rate increases exponentially with surface temperature and is independent of the velocity, illustrating that surface reaction controls the fouling process. By analysis of the morphology of scale, two types of crystal (calcite and aragonite) are formed. The lower the temperature and ion concentration, the longer the induction period and the higher the percentage of calcite nreciDitated.
基金Project(G-0805-10156) supported by US Energy Foundation
文摘The optimum control strategy and the saving potential of all variable chiller plant under the conditions of changing building cooling load and cooling water supply temperature were investigated. Based on a simulation model of water source chiller plant established in dynamic transient simulation program (TRNSYS),the four-variable quadratic orthogonal regression experiments were carried out by taking cooling load,cooling water supply temperature,cooling water flow rate and chilled water flow rate as variables,and the fitting formulas expressing the relationships between the total energy consumption of chiller plant with the four selected parameters was obtained. With the SAS statistical software and MATHEMATICA mathematical software,the optimal chilled water flow rate and cooling water flow rate which result in the minimum total energy consumption were determined under continuously varying cooling load and cooling water supply temperature. With regard to a chiller plant serving an office building in Shanghai,the total energy consumptions under different control strategies were computed in terms of the forecasting function of cooling load and water source temperature. The results show that applying the optimal control strategy to the chiller plant can bring a saving of 23.27% in power compared with the corresponding conventional variable speed plant,indicating that the optimal control strategy can improve the energy efficiency of chiller plant.
文摘Weight lost method was used to comparatively study the corrosion behavior of four different metals under the dosage of chlorine dioxide, chlorine and their mixture respectively. The experimental results indicated that chlorine causes the most serious corrosion of carbon steel, and the higher the concentration of chlorine, the more serious the corrosion. On the contrary, metals corrosion is the least serious in the case of chlorine dioxide. The results further revealed that chlorine dioxide is the most effective water treatment reagent, making it the best choice to use extensively in circulated cooling water disinfection and corrosion control.
基金supported by the National Natural Science Foundation of China (No.20707040)the State Key Laboratory of Pollution Control and Resource Reuse Foundation(No. PCRRF08002).
文摘A series of orthogonal array experiments were conducted using carbon source, ammonia nitrogen and total phosphorus (TP) as major influencing factors to investigate the effects of nutrients on biofouling formation and preponderant bacteria diversity in the recirculatiug cooling water system. Carbon source was demonstrated to be the most significant determinant affecting the biofouling formation. A minimum biofouling outcome was obtained when BOD2, NHa+-N and TP were 25, 10, and 1 mg/L, respectively. Then the preponderant bacteria strains in biofouling mass under two typical culture conditions (negative and favorable) were identified applying both traditional biochemical methods and further molecular biology technology with phylogenetic affiliation analysis, which indicated that Enterobacteriaceae Enterobacter, Micrococcaceae Staphylococcus, Bacillaceae Bacillus, Enterobacteriaceae Proteus, Neisseriaceae Neisseria and Pseudomonadaceae Pseudomonas were dominant under negative condition, while Enterobacteriaceae Klebsiella, Enterobacteriaceae Enterobacter and Microbacterium - under favorable one.
基金Project 51306198 supported by the National Natural Science Foundation of China
文摘Low critical temperature limits the application of CO_2 trans-critical power cycle.The binary mixture of R290/CO_2has higher critical temperature.Using mixture fluid may solve the problem that subcritical CO_2 is hardly condensed by conventional cooling water.In this article,theoretical analysis is executed to study the performance of the zeotropic mixture for trans-critical power cycle using low-grade liquid heat source with temperature of200℃.The results indicated that the problem that CO_2 can't be condensed in power cycle by conventional cooling water can be solved by mixing R290 to CO_2.Variation trend of outlet temperature of thermal oil in supercritical heater with heating pressure is determined by the composition of the mixture fluid.Gliding temperature causes the maximum outlet temperature of cooling water with the increase of mass fraction of R290.There are the maximum values for cycle thermal efficiency and net power output with the increase of supercritical heating pressure.
基金supported by the Foundation for Top Talents Program of China University of Petroleum
文摘Mesoporous SiO_2 microspheres were synthesized using the sol-gel method and were characterized by TEM, FT-IR and BET techniques. The diameter of the microspheres is about 100—150 nm, and the average mesopore diameter is 2.55 nm, while the specific surface area is 1 088.9 m2/g. Mesoporous SiO_2 microspheres adsorb glutaraldehyde and immobilize laccase by means of the aldehyde group in glutaral which can react with the amidogen of laccase. The immobilization conditions were optimized at a glutaraldehyde concentration of 0.75%, a crosslinking time of 8 h, a laccase concentration of 0.04 L/L and an immobilization time of 10 h. When diesel leakage concentration was 80 mg/L, the highest corrosion inhibition efficiency of immobilized laccase reached 49.23%, which was slightly lower than the corrosion inhibition efficiency of free laccase(59%). The diesel degradation ratio could reach up to 45%. It has been proved that the immobilized laccase could degrade diesel to inhibit corrosion.
基金Supported by the Knowledge Innovation Program of the Chinese Academy of Sciences (Nos.KZCX1-YW-12-01KZCX2-YW-BR-04)+1 种基金the National Natural Science Foundation of China (Nos.40876007,40806006)the National High Technology Research and Development Program of China (863 Program) (No.2008AA09A402)
文摘We deployed two ADCP mooring systems west of the Luzon Strait in August 2008,and measured the upper ocean currents at high frequency.Two typhoons passed over the moorings during approximately one-month observation period.Using ADCP observations,satellite wind and heat flux measurements,and high-resolution model assimilation products,we studied the response of the upper ocean to typhoons.The first typhoon,Nuri,passed over one of the moorings,resulting in strong Ekman divergence and significant surface cooling.The cooling of surface water lagged the typhoon wind forcing about one day and lasted about five days.The second typhoon,Sinlaku,moved northward east of the Luzon Strait,and did not directly impact currents near the observation regions.Sinlaku increased anomalous surface water transport exchange across the Luzon Strait,which modulated the surface layer current of the Kuroshio.
基金Project(2011B061200043)supported by the Guangdong Provincial Department of Science and Technology,China
文摘Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.
文摘The aim of this paper is to collect information about dairy cow's behaviour connected to different environmental conditions. During summer 2009 and winter 2010 experimental trials were arranged to verify the behaviour of dairy cows in a farm located in Po Plain (Italy). The barn was provided with an air-water cooling system, based on the use of fans and sprinklers placed only in the feeding alley. Two different trials were carried out. The first experiment was targeted on verifying the use of the cubicles by the cows in relation to the availability of the cooling system only in feeding area. The second trial aimed at testing the effectiveness of zone cooling systems placed in the front of cubicles. For this purpose three cubicles in the barn were provided with cooling systems, based on the input of high velocity conditioned air streams. The results clearly remark that the behaviour of the animals is greatly influenced by the environmental conditions. With high temperatures the use of the cubicles is deeply reduced and the animals prefer to stay in feeding area, thus benefiting from the cooling effect of water sprinkled by the showers and of the air streams created by the fans. With air temperatures increasing from 21℃ to 33 ℃ the cows reduce the staying in the cubicles, which gets down from 540 to 32% (r2 = 0.2608). As regards the efficacy of zone cooling system in the cubicles, the results are not particularly encouraging. The cows continue to use the cubicles without changing the behaviour in relation to the presence of conditioned air flow.
文摘The wastewater discharged from the 1.0 Mt/a ethylene unit at Maoming Petrochemical Company was separated according to its quality, and a major part ofwastewater with better quality was properly treated via the process of"IRABF + high-efficiency fiber filtering + disinfection" to make the wastewater quality comply with the quality of recycled cooling water, so that the technique for reused petrochemical wastewater was more reliable technically and more reasonable economically,
基金National Natural Science Foundation of China(No.50706028)Shanghai Leading Academic Discipline Project,China(No.S30503)
文摘An experimental investigation of natural gas hydrate formation has been conducted in a high-pressure water spraying reactor,which is cooled by the circulation water through an external cooling jacket.The results show that the morphology of hydrates formed by water spraying is like ice-slurry,which depends on the initial pressure and temperature.At a certain reaction pressure,the rate of hydrate formation is increasing with lower temperature.And also,the induction time of hydrate formation can be greatly shortened by water spraying compared to a quiescent system.Solution with appropriate surfactant sodium dodecyl sulfate (SDS) is found to improve the formation rate obviously.
基金Supported by National Natural Science Foundation of China (No. 50376044)
文摘An exhaust heat recovery generator is proposed to be integrated with conventional gas-fired triple-effect LiBr/water absorption cooling cycles to improve system energy efficiency. As a case study, simulation of the novel cycle based on promising parallel flow with cooling capacity of 1 150 kW is carried out under various heat recovery generator vapor production ratios ranging from 0 to 3.5%. The life cycle saving economic analysis, for which the annual gas conservation is estimated with Bin method, is employed to prove the worthiness of extra expenditure. Results show that the optimum gas saving revenue is obtained at 2.8% heat recovery generator vapor production ratio with 42 kW exhaust heat recovered, and the system energy efficiency is improved from 1.78 to 1.83. The initial investment of exchanger can be paid back within 7 years and 9 000 CNY of gas saving revenue will be achieved over the 15-year life cycle of the machine. This technology can be easily implemented and present desirable economic effects, which is feasible to the development of triple-effect absorption cycles.