A simple and sensitive high-performance liquid chromatography mass spectrometry(LC-MS)method for the simultaneous determination of irbesartan and hydrochlorothiazide in human plasma was developed and applied to a ph...A simple and sensitive high-performance liquid chromatography mass spectrometry(LC-MS)method for the simultaneous determination of irbesartan and hydrochlorothiazide in human plasma was developed and applied to a pharmacokinetic study. Acetaminophen was used as the internal standard(IS).Sample pretreatment using liquid-liquid extraction with ethyl acetate was used.The analysis was carried out on an Elite SinoChrom ODS-BP C_(18)column with a mobile phase composed of acetonitrile-water (35:65,v/v).Target ions were [M-H]^-m/z 427.25 for irbesartan,[M-H]^-m/z 295.95 for hydrochlorothiazide and [M-H]^- m/z 150.05 for the IS via an electrospray ionization(ESI)source.The intra-and inter-day precision(RSD%)was below 14.5% for irbesartan and hydrochlorothiazide,and the accuracy(RE%)was less than 1.9% and-2.0% for irbesartan and hydrochlorothiazide,respectively.The linear calibration curves were obtained in the concentration range of 10-5000 ng/mL (r0.99)for irbesartan and 1-200 ng/mL(r0.99)for hydrochlorothiazide with the lower limit of quantification(LLOQ)of 10 ng/mL and 1 ng/mL,respectively.The method was applied to a clinical pharmacokinetic study of a tablet containing irbesartan and hydrochlorothiazide in healthy Chinese volunteers after oral administration.展开更多
文摘A simple and sensitive high-performance liquid chromatography mass spectrometry(LC-MS)method for the simultaneous determination of irbesartan and hydrochlorothiazide in human plasma was developed and applied to a pharmacokinetic study. Acetaminophen was used as the internal standard(IS).Sample pretreatment using liquid-liquid extraction with ethyl acetate was used.The analysis was carried out on an Elite SinoChrom ODS-BP C_(18)column with a mobile phase composed of acetonitrile-water (35:65,v/v).Target ions were [M-H]^-m/z 427.25 for irbesartan,[M-H]^-m/z 295.95 for hydrochlorothiazide and [M-H]^- m/z 150.05 for the IS via an electrospray ionization(ESI)source.The intra-and inter-day precision(RSD%)was below 14.5% for irbesartan and hydrochlorothiazide,and the accuracy(RE%)was less than 1.9% and-2.0% for irbesartan and hydrochlorothiazide,respectively.The linear calibration curves were obtained in the concentration range of 10-5000 ng/mL (r0.99)for irbesartan and 1-200 ng/mL(r0.99)for hydrochlorothiazide with the lower limit of quantification(LLOQ)of 10 ng/mL and 1 ng/mL,respectively.The method was applied to a clinical pharmacokinetic study of a tablet containing irbesartan and hydrochlorothiazide in healthy Chinese volunteers after oral administration.