Wearable devices have great application potential in the next generation of smart portable electronics,especially in the fields of medical monitoring,soft robotics,artificial intelligence,and human-machine interfaces....Wearable devices have great application potential in the next generation of smart portable electronics,especially in the fields of medical monitoring,soft robotics,artificial intelligence,and human-machine interfaces.Piezoelectric flexible strain sensors are key components of wearable devices.However,existing piezoelectric flexible strain sensors have certain limitations in weak signal monitoring due to their large modulus and low sensitivity.To solve this problem,the concept of Kirigami(paper-cutting)was introduced in this study to design the sensor structure.By comparing the Kirigami structures of different basic structures,the serpentine structure was determined as the basic configuration of the sensor.The serpentine structure not only provides excellent tensile properties,but also significantly improves the sensitivity of the sensor,which performs well in monitoring weak signals.On this basis,the adhesion properties of the flexible sensor were analyzed and tested,and the optimal ratio of the substrate was selected for preparation.In addition,a low-cost and rapid prototyping process for stretchable patches was established in this study.Using this technology,we prepared the sensor device and tested its performance.Finally,we successfully developed a flexible sensor with a sensitivity of 0.128 mV/μɛand verified its feasibility for wrist joint motion monitoring applications.This result opens up new avenues for the recovery care of tenosynovitis patients after surgery.展开更多
Aim To determine efficiency of multi-range hydro-mechanical stepless transmis- sion(HMT).Methods Ageneral model of HMT was of HMT was structured.On the basis of power flow analysis, the efficiency was obtained,Results...Aim To determine efficiency of multi-range hydro-mechanical stepless transmis- sion(HMT).Methods Ageneral model of HMT was of HMT was structured.On the basis of power flow analysis, the efficiency was obtained,Results efficiency of multi-range HMT changes continuously with output speed in speed range and is higher than the highest point of the hydraulic efficiency,The volumetric efficiency can potentially result in the speed fluctuation, which can be reduced or eliminated through controlling the ratio of the displacements ofhydraulic unity properly or changing the point of range exchanging .And the mechanical- constant output torque or different output torque under the condition of constant pressure when the transmission works in different parts of a range,Conclusion The multi-range HMT is an ideal stepless transmission with high efficiency.展开更多
The method of volume identification in pneumatics was studied through theoretical analysis and experimental investigation. Regarding discharging from a container as a thermodynamic process with invariable index the d...The method of volume identification in pneumatics was studied through theoretical analysis and experimental investigation. Regarding discharging from a container as a thermodynamic process with invariable index the dependence of the container’s volume on the pressure in the container and the index, during discharging at the velocity of sound, is deduced. Then through a lot of experiments, the value of index n of the process is found with a given precision and a specified volume range. Furthermore, the feasibility and practicability of this method are verified by experiments.展开更多
A rectangular finite element for laminated plate with bonded and/or embedded piezoelectric sensors and actuators is developed based on the variational principle and the first order shear deformation theory. The elemen...A rectangular finite element for laminated plate with bonded and/or embedded piezoelectric sensors and actuators is developed based on the variational principle and the first order shear deformation theory. The element has four-node, 20-degrees-of-freedom with one potential degree of freedom for each piezoelectric layer to represent the piezoelectric behavior. The higher order derivation of deflection is obtained by using the normal rotation expressions to take the effects of transverse shear deformation into considerations. The finite element can accurately simulate the deformation of both thin and moderately thick plates. A Fortran program is written and a number of benchmark tests are exercised to verify its effectiveness. Results are compared well with the existing data. The unbalanced composite with piezoelectric layers is then analyzed by using the model. Results show that the changes of the ratio between the thickness of positive angle layers and the negative angle layers have an effect on the deformation of the structure under the same electric loading.展开更多
Active vibration control and stability analysis of cantilever plate are discussed. Based on the analysis of characteristic equation of the closed loop control system, it is shown that such an active control may incre...Active vibration control and stability analysis of cantilever plate are discussed. Based on the analysis of characteristic equation of the closed loop control system, it is shown that such an active control may increase damping properties of the system, meanwhile it may result in instability of the system. It is stable when the feedback only occurs between the collocated sensors and actuators, but it may be unstable when there exists the feedback between sensors and actuators, which mainly depends on the property of the gain matrix of feedback. If the gain matrix is symmetric and definitely positive, the system is stable.展开更多
基金supported by National Natural Science Foundation of China(Nos.62301509,62304209)Key Research and Development Program of Shanxi Province(No.202302030201001)Fundamental Research Program of Shanxi Province(Nos.202203021222079,0210302123203,202103021223185).
文摘Wearable devices have great application potential in the next generation of smart portable electronics,especially in the fields of medical monitoring,soft robotics,artificial intelligence,and human-machine interfaces.Piezoelectric flexible strain sensors are key components of wearable devices.However,existing piezoelectric flexible strain sensors have certain limitations in weak signal monitoring due to their large modulus and low sensitivity.To solve this problem,the concept of Kirigami(paper-cutting)was introduced in this study to design the sensor structure.By comparing the Kirigami structures of different basic structures,the serpentine structure was determined as the basic configuration of the sensor.The serpentine structure not only provides excellent tensile properties,but also significantly improves the sensitivity of the sensor,which performs well in monitoring weak signals.On this basis,the adhesion properties of the flexible sensor were analyzed and tested,and the optimal ratio of the substrate was selected for preparation.In addition,a low-cost and rapid prototyping process for stretchable patches was established in this study.Using this technology,we prepared the sensor device and tested its performance.Finally,we successfully developed a flexible sensor with a sensitivity of 0.128 mV/μɛand verified its feasibility for wrist joint motion monitoring applications.This result opens up new avenues for the recovery care of tenosynovitis patients after surgery.
文摘Aim To determine efficiency of multi-range hydro-mechanical stepless transmis- sion(HMT).Methods Ageneral model of HMT was of HMT was structured.On the basis of power flow analysis, the efficiency was obtained,Results efficiency of multi-range HMT changes continuously with output speed in speed range and is higher than the highest point of the hydraulic efficiency,The volumetric efficiency can potentially result in the speed fluctuation, which can be reduced or eliminated through controlling the ratio of the displacements ofhydraulic unity properly or changing the point of range exchanging .And the mechanical- constant output torque or different output torque under the condition of constant pressure when the transmission works in different parts of a range,Conclusion The multi-range HMT is an ideal stepless transmission with high efficiency.
文摘The method of volume identification in pneumatics was studied through theoretical analysis and experimental investigation. Regarding discharging from a container as a thermodynamic process with invariable index the dependence of the container’s volume on the pressure in the container and the index, during discharging at the velocity of sound, is deduced. Then through a lot of experiments, the value of index n of the process is found with a given precision and a specified volume range. Furthermore, the feasibility and practicability of this method are verified by experiments.
文摘A rectangular finite element for laminated plate with bonded and/or embedded piezoelectric sensors and actuators is developed based on the variational principle and the first order shear deformation theory. The element has four-node, 20-degrees-of-freedom with one potential degree of freedom for each piezoelectric layer to represent the piezoelectric behavior. The higher order derivation of deflection is obtained by using the normal rotation expressions to take the effects of transverse shear deformation into considerations. The finite element can accurately simulate the deformation of both thin and moderately thick plates. A Fortran program is written and a number of benchmark tests are exercised to verify its effectiveness. Results are compared well with the existing data. The unbalanced composite with piezoelectric layers is then analyzed by using the model. Results show that the changes of the ratio between the thickness of positive angle layers and the negative angle layers have an effect on the deformation of the structure under the same electric loading.
文摘Active vibration control and stability analysis of cantilever plate are discussed. Based on the analysis of characteristic equation of the closed loop control system, it is shown that such an active control may increase damping properties of the system, meanwhile it may result in instability of the system. It is stable when the feedback only occurs between the collocated sensors and actuators, but it may be unstable when there exists the feedback between sensors and actuators, which mainly depends on the property of the gain matrix of feedback. If the gain matrix is symmetric and definitely positive, the system is stable.