Based on the engineering background of double-unit face mining under complicated geological conditions and the lagging fully-mechanized face surpassing the fore mechanized face of double-unit face in Zhou Yuanshan coa...Based on the engineering background of double-unit face mining under complicated geological conditions and the lagging fully-mechanized face surpassing the fore mechanized face of double-unit face in Zhou Yuanshan coal mine, strata-pressure behavior in the process was analyzed based on FLAC3D and on-site measurement. The results show that the stress concentration factor of superposition abutment pressure and the alternate distance of double-unit face are meeting gauss function, the relationship between the depth of stress concentration point and alternate distance also meets gaussian function. When the alternate distance is larger than 24 m, the superimposition of pilot support pressure in the double-unit face is weak. When the alternate distance is more than 12-15 m, the changes of the roof subsidence coefficient and the depth of stress con- centration point are stabilized; when the alternate distance is 3-6 m, the fore working face end is in the greatest impact area of superposition abutment pressure, this area should be avoided in determining the reasonable alternate distance.展开更多
In order to clarify the effect of tip clearance (TC) size on fan performance and the flow field at rotor outlet in a small semi-open axial fan, the experimental investigation was carried out. The tip diameter of tes...In order to clarify the effect of tip clearance (TC) size on fan performance and the flow field at rotor outlet in a small semi-open axial fan, the experimental investigation was carried out. The tip diameter of test fan rotor was 180mm and test TC sizes were lmm (TC=1mm) and 4mm (TC=4mm). Fan characteristics tests were carried out for two cases of TC size and three-dimensional velocity fields at rotor outlet were measured using a single slant hot-wire probe at four flow-rate conditions. As a result, it was found that the pressure - flow-rate characteristics curves for two cases showed almost the same tendency. However, the ensemble averaged velocity profiles along radial measurement stations of TC-4mm largely changed compared with that of TC=1mm in cases of small flow-rate condition. From the phase-locked averaging results, it was also found that the vortex existed in the rotor outlet flow field of high flow-rate condition for each TC case. Compared with the vortices for TC=1mm and TC=4mm, the vortex for TC=4mm was stronger than that for TC=1mm.展开更多
基金Supported by the National Natural Science Foundation of China (50974059)
文摘Based on the engineering background of double-unit face mining under complicated geological conditions and the lagging fully-mechanized face surpassing the fore mechanized face of double-unit face in Zhou Yuanshan coal mine, strata-pressure behavior in the process was analyzed based on FLAC3D and on-site measurement. The results show that the stress concentration factor of superposition abutment pressure and the alternate distance of double-unit face are meeting gauss function, the relationship between the depth of stress concentration point and alternate distance also meets gaussian function. When the alternate distance is larger than 24 m, the superimposition of pilot support pressure in the double-unit face is weak. When the alternate distance is more than 12-15 m, the changes of the roof subsidence coefficient and the depth of stress con- centration point are stabilized; when the alternate distance is 3-6 m, the fore working face end is in the greatest impact area of superposition abutment pressure, this area should be avoided in determining the reasonable alternate distance.
文摘In order to clarify the effect of tip clearance (TC) size on fan performance and the flow field at rotor outlet in a small semi-open axial fan, the experimental investigation was carried out. The tip diameter of test fan rotor was 180mm and test TC sizes were lmm (TC=1mm) and 4mm (TC=4mm). Fan characteristics tests were carried out for two cases of TC size and three-dimensional velocity fields at rotor outlet were measured using a single slant hot-wire probe at four flow-rate conditions. As a result, it was found that the pressure - flow-rate characteristics curves for two cases showed almost the same tendency. However, the ensemble averaged velocity profiles along radial measurement stations of TC-4mm largely changed compared with that of TC=1mm in cases of small flow-rate condition. From the phase-locked averaging results, it was also found that the vortex existed in the rotor outlet flow field of high flow-rate condition for each TC case. Compared with the vortices for TC=1mm and TC=4mm, the vortex for TC=4mm was stronger than that for TC=1mm.