During the exploitation of offshore oil and gas,it is easy to form severe slugging which can cause great harm in the riser connecting wellheads and offshore platform preprocessing system.The flow pattern and pressure ...During the exploitation of offshore oil and gas,it is easy to form severe slugging which can cause great harm in the riser connecting wellheads and offshore platform preprocessing system.The flow pattern and pressure fluctuation of severe slugging were studied in an experimental simulation system with inner diameter of 0.051 m.It is found that severe slugging can be divided into three severe slugging regimes:regime I at low gas and liquid flow rates with large pressure fluctuation,intermittent flow of liquid and gas in the riser,and apparent cutoff of liquid phase,regime II at high gas flow rate with non-periodic fluctuation and discontinuous liquid outflow and no gas cutoff,regime III at high liquid flow rate with degenerative pressure fluctuation in form of relatively stable bubbly or plug flow.The results indicate that severe slugging still occurs when the declination angle of pipeline is 0,and there are mainly two kinds of regimes:regime I and regime II.As the angle increases,the formation ranges of regime I and regime III increase slightly while that of regime II is not affected.With the increase of gas superficial velocity and liquid superficial velocity,the pressure fluctuation at the bottom of riser increases initially and then decreases.The maximum value of pressure fluctuation occurs at the transition boundary of regimes I and II.展开更多
The duct static pressure reset (DSPR) control method is a popular modern control method widely applied to variable air volume (VAV) systems of commercial buildings. In this paper, a VAV system simulation program was u...The duct static pressure reset (DSPR) control method is a popular modern control method widely applied to variable air volume (VAV) systems of commercial buildings. In this paper, a VAV system simulation program was used to predict the system performance and zone air temperature of two kinds of layouts that were applied to a typical floor of an existing building office in Hong Kong. The position where the static pressure sensor was placed should affect the zones temperature and energy consumption. The comparison of predictions of the two kinds of layouts indicates that with the same DSPR control method the layout of the air duct might influence the fan control result and energy savings.展开更多
基金Supported by the National High Technology Research and Development Program of China(2006AA09Z302)
文摘During the exploitation of offshore oil and gas,it is easy to form severe slugging which can cause great harm in the riser connecting wellheads and offshore platform preprocessing system.The flow pattern and pressure fluctuation of severe slugging were studied in an experimental simulation system with inner diameter of 0.051 m.It is found that severe slugging can be divided into three severe slugging regimes:regime I at low gas and liquid flow rates with large pressure fluctuation,intermittent flow of liquid and gas in the riser,and apparent cutoff of liquid phase,regime II at high gas flow rate with non-periodic fluctuation and discontinuous liquid outflow and no gas cutoff,regime III at high liquid flow rate with degenerative pressure fluctuation in form of relatively stable bubbly or plug flow.The results indicate that severe slugging still occurs when the declination angle of pipeline is 0,and there are mainly two kinds of regimes:regime I and regime II.As the angle increases,the formation ranges of regime I and regime III increase slightly while that of regime II is not affected.With the increase of gas superficial velocity and liquid superficial velocity,the pressure fluctuation at the bottom of riser increases initially and then decreases.The maximum value of pressure fluctuation occurs at the transition boundary of regimes I and II.
文摘The duct static pressure reset (DSPR) control method is a popular modern control method widely applied to variable air volume (VAV) systems of commercial buildings. In this paper, a VAV system simulation program was used to predict the system performance and zone air temperature of two kinds of layouts that were applied to a typical floor of an existing building office in Hong Kong. The position where the static pressure sensor was placed should affect the zones temperature and energy consumption. The comparison of predictions of the two kinds of layouts indicates that with the same DSPR control method the layout of the air duct might influence the fan control result and energy savings.