Jet grouting is a method for improving of soil and its physical characteristics.However,in this method,grouting of cement slurry with high pressure and velocity may cause damaging to soil structure,and then excavated ...Jet grouting is a method for improving of soil and its physical characteristics.However,in this method,grouting of cement slurry with high pressure and velocity may cause damaging to soil structure,and then excavated grains of soil are removed from the borehole and replaced with cement slurry.The grains,which are remained around the borehole,mixed with slurry(cement) in-situ,can create an improved mass of soil.This mass is named"Soilcrete".Soilcrete mass has special characteristics such as high strength,low deformability and very low permeability.In this paper,principles of jet grouting and effective parameters have been analyzed.Then the test results obtained from Soilcrete column have been investigated.Finally,the paper concludes with presenting amount of principle jet grouting parameters at foundation of Shahriar dam according to the results of jet grouting test.Based on the measurements,the diameter,Soilcrete UCS(uniaxial compression strength),amount of the water,grout and air pressure and lifting and rotating speed in original site of jet grouting are 1.2~1.5 m,2~3 MPa,370~390 bar,10~15 bar,6~8 bar,7~8 cm/min and 7~8 cm/min,respectively.Also it can be seen that while the column diameter falls within the upper half of the range,some values of the compressive strength are close to the lower limit of the range.展开更多
To estimate a compressive strength from existing concrete structures by core drilling are usually gathered with a diameter specimen of 100 mm or three times of maximum coarse aggregate size and examined by uniaxial co...To estimate a compressive strength from existing concrete structures by core drilling are usually gathered with a diameter specimen of 100 mm or three times of maximum coarse aggregate size and examined by uniaxial compressive strength (UCS). It is relatively difficult to gather a large sized core, and a pit place will be limited by main members. To get an alternative solution with smaller specimen, point load test (PLT) has been sele,:ted which is a simple test and widely accepted in rock materials research, but relatively new in concrete. The reliability of PLT is evaluated by extracting a lot of core drilled specimen from ready mixed concrete blocks with maximum coarse aggregate size, G of 20 mm in representative of architectural structures and 40 mm in representative of civil structures on the range of concrete grade from 16 to 50. Compressive strengths were classified into general categories, conversion factors were determined, and scattering characteristics were also investigated. The relationship between point load index (Is) and compressive strength of concrete core specimen (fcc) can be written as linear approximation as fcc = k.Is- C.展开更多
文摘Jet grouting is a method for improving of soil and its physical characteristics.However,in this method,grouting of cement slurry with high pressure and velocity may cause damaging to soil structure,and then excavated grains of soil are removed from the borehole and replaced with cement slurry.The grains,which are remained around the borehole,mixed with slurry(cement) in-situ,can create an improved mass of soil.This mass is named"Soilcrete".Soilcrete mass has special characteristics such as high strength,low deformability and very low permeability.In this paper,principles of jet grouting and effective parameters have been analyzed.Then the test results obtained from Soilcrete column have been investigated.Finally,the paper concludes with presenting amount of principle jet grouting parameters at foundation of Shahriar dam according to the results of jet grouting test.Based on the measurements,the diameter,Soilcrete UCS(uniaxial compression strength),amount of the water,grout and air pressure and lifting and rotating speed in original site of jet grouting are 1.2~1.5 m,2~3 MPa,370~390 bar,10~15 bar,6~8 bar,7~8 cm/min and 7~8 cm/min,respectively.Also it can be seen that while the column diameter falls within the upper half of the range,some values of the compressive strength are close to the lower limit of the range.
文摘To estimate a compressive strength from existing concrete structures by core drilling are usually gathered with a diameter specimen of 100 mm or three times of maximum coarse aggregate size and examined by uniaxial compressive strength (UCS). It is relatively difficult to gather a large sized core, and a pit place will be limited by main members. To get an alternative solution with smaller specimen, point load test (PLT) has been sele,:ted which is a simple test and widely accepted in rock materials research, but relatively new in concrete. The reliability of PLT is evaluated by extracting a lot of core drilled specimen from ready mixed concrete blocks with maximum coarse aggregate size, G of 20 mm in representative of architectural structures and 40 mm in representative of civil structures on the range of concrete grade from 16 to 50. Compressive strengths were classified into general categories, conversion factors were determined, and scattering characteristics were also investigated. The relationship between point load index (Is) and compressive strength of concrete core specimen (fcc) can be written as linear approximation as fcc = k.Is- C.