In recent years, the increasing application of nonlinear and unbalanced electronic equipment and large single phase loads have made voltage imbalance a serious problem in power distribution systems. A novel approach h...In recent years, the increasing application of nonlinear and unbalanced electronic equipment and large single phase loads have made voltage imbalance a serious problem in power distribution systems. A novel approach has been proposed to eliminate voltage imbalance and disturbances. The main strategy of this scheme is based on series active filter. By improving control circuit toward existing schemes and proposing a new strategy to control the voltage amplitude, simultaneous elimination of voltage imbalance, faults, voltage harmonics and also compensation of voltage drop in transmission lines become possible. Eventually, the voltage on the load side is a perfectly balanced three phase voltage with specific proper amplitude. The proposed scheme has been simulated in a test network and the results show high capability of this scheme for the complete elimination of imbalance without phase shift.展开更多
Generally speaking, hydraulic control systems can be divided into two different driving concepts. The first one is the well-known hydraulic valve-controlled system and the second one is the pump-controlled system. The...Generally speaking, hydraulic control systems can be divided into two different driving concepts. The first one is the well-known hydraulic valve-controlled system and the second one is the pump-controlled system. The former possesses the feature of fast dynamic response. However, the poor energy-saving performance is its major fault. On the contrary, the hydraulic pump-controlled system has the significant advantage of energy-saving which meets the current demand in modem machine design. In this paper, the simulation analysis using MatLab/SimuLink and DSHplus software for a newly developed energy-saving hydraulic tube bender is conducted. Instead of the conventional fixed displacement hydraulic pump, the new hydraulic tube bender utilizes an internal gear pump with AC servomotor as its driving power source. In the new energy-saving hydraulic circuit, the use of conventional pressure relief valve and unloading valve are no longer necessary since the demanded flow-rate and pressure output can be precisely obtained by continuously changing the speed of the AC servomotor. In addition, two closed-loop control schemes using fuzzy sliding-mode controller are adopted and compared. To compare the energy-saving control systems, such as load-sensing control system, constant supply pressure control scheme and conventional hydraulic control scheme. Furthermore, the simulation results also show that the newly developed hydraulic tube bender can save up to 43% of energy consumption in a working cycle as compared to the conventional hydraulic tube bender.展开更多
If the rigidity of a mechanism is stiff enough, the position synchronous error of the two cylinders driving one degree-of-freedom (DOF) of the mechanism may be less than the resolution of position sensors. To handle...If the rigidity of a mechanism is stiff enough, the position synchronous error of the two cylinders driving one degree-of-freedom (DOF) of the mechanism may be less than the resolution of position sensors. To handle this synchronization problem this paper proposes a force/position switching scheme, which partitions the two cylinders into a master cylinder and a slave cylinder. The master cylinder is always position tracking controlled by a second-order sliding mode controller and the slave cylinder is integrated with a force tracking controller which is a first order sliding mode controller. When the position tracking error is less than a given value, the slave cylinder switches to be force controlled. Two synchronization control methods are presented based on the switching scheme: the master - master + force/position switching control and the master - slave + force/position switching control. Simulations show that the formance compared with two given proposed synchronization control position-based control methods. methods can get a better per-展开更多
文摘In recent years, the increasing application of nonlinear and unbalanced electronic equipment and large single phase loads have made voltage imbalance a serious problem in power distribution systems. A novel approach has been proposed to eliminate voltage imbalance and disturbances. The main strategy of this scheme is based on series active filter. By improving control circuit toward existing schemes and proposing a new strategy to control the voltage amplitude, simultaneous elimination of voltage imbalance, faults, voltage harmonics and also compensation of voltage drop in transmission lines become possible. Eventually, the voltage on the load side is a perfectly balanced three phase voltage with specific proper amplitude. The proposed scheme has been simulated in a test network and the results show high capability of this scheme for the complete elimination of imbalance without phase shift.
文摘Generally speaking, hydraulic control systems can be divided into two different driving concepts. The first one is the well-known hydraulic valve-controlled system and the second one is the pump-controlled system. The former possesses the feature of fast dynamic response. However, the poor energy-saving performance is its major fault. On the contrary, the hydraulic pump-controlled system has the significant advantage of energy-saving which meets the current demand in modem machine design. In this paper, the simulation analysis using MatLab/SimuLink and DSHplus software for a newly developed energy-saving hydraulic tube bender is conducted. Instead of the conventional fixed displacement hydraulic pump, the new hydraulic tube bender utilizes an internal gear pump with AC servomotor as its driving power source. In the new energy-saving hydraulic circuit, the use of conventional pressure relief valve and unloading valve are no longer necessary since the demanded flow-rate and pressure output can be precisely obtained by continuously changing the speed of the AC servomotor. In addition, two closed-loop control schemes using fuzzy sliding-mode controller are adopted and compared. To compare the energy-saving control systems, such as load-sensing control system, constant supply pressure control scheme and conventional hydraulic control scheme. Furthermore, the simulation results also show that the newly developed hydraulic tube bender can save up to 43% of energy consumption in a working cycle as compared to the conventional hydraulic tube bender.
基金Supported by the Major State Basic Research Development Program of China(No.2006CB5406)Important National Science&Technology Specific Projects(No.2009ZX04002-061,2009ZX04004-102)
文摘If the rigidity of a mechanism is stiff enough, the position synchronous error of the two cylinders driving one degree-of-freedom (DOF) of the mechanism may be less than the resolution of position sensors. To handle this synchronization problem this paper proposes a force/position switching scheme, which partitions the two cylinders into a master cylinder and a slave cylinder. The master cylinder is always position tracking controlled by a second-order sliding mode controller and the slave cylinder is integrated with a force tracking controller which is a first order sliding mode controller. When the position tracking error is less than a given value, the slave cylinder switches to be force controlled. Two synchronization control methods are presented based on the switching scheme: the master - master + force/position switching control and the master - slave + force/position switching control. Simulations show that the formance compared with two given proposed synchronization control position-based control methods. methods can get a better per-