期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
衰老矿井采区优化设计的若干问题 被引量:1
1
作者 张小军 《矿山压力与顶板管理》 北大核心 2002年第2期107-109,共3页
介绍了矿井及 1 采区概况 ,并就 1 采区的村庄搬迁进行可行性论证 ;从衰老矿井特点出发 。
关键词 优化设计 衰老矿井 压煤采区 迁村开采 煤量
下载PDF
Technical scheme and application of pressure-relief gas extraction in multi-coal seam mining region 被引量:3
2
作者 chang xiaocun tian hui 《International Journal of Mining Science and Technology》 EI CSCD 2018年第3期483-489,共7页
A pressure relief gas extraction technical model of a typical mining area is proposed based on coal and gas simultaneous extraction theory. Flac3 Dwas employed to model vertical stress and displacement contour plot ch... A pressure relief gas extraction technical model of a typical mining area is proposed based on coal and gas simultaneous extraction theory. Flac3 Dwas employed to model vertical stress and displacement contour plot characteristics of non-outburst coal seam(No. 4) on top of outburst coal seam(No. 2) along strike and incline directions. Field investigations were also conducted to verify the scientific nature of the simulation. The results demonstrate that gas pressure in No. 2 coal seam dropped to approximately 0.55 MPa in the pressure relief multi-coal seam. The highest expansion rate of the coal mine reached up to 2.58%.The pressure-relief angle was 76° along the incline direction and 60° along the strike direction. As the expansion rate and pressure-relief angle increased and the gas pressure decreased, a large amount of gas flowed into the gob of No. 4 from No. 2 coal seam and was later discharged through specific gas pipes,which eliminated No. 2 outburst risks. This study resulted in positive outcomes in that gas extraction time was reduced by 13.5 days, due to pressure relief, and drilling work load was reduced by 0.1161 m/t coal. This method ensures that gas is discharged from the outburst coal seam quickly and safely,demonstrating that the proposed technical model of pressure-relief gas extraction is effective in a multi-coal seam region. 展开更多
关键词 Coal seams group Stress field Displacement field Expansion deformation Pressure-relief angle
下载PDF
Experimental research on overlying strata movement and fracture evolution in pillarless stress-relief mining 被引量:22
3
作者 Junhua Xue Hanpeng Wang +3 位作者 Wei Zhou Bo Ren Changrui Duan Dongsheng Deng 《International Journal of Coal Science & Technology》 EI 2015年第1期38-45,共8页
In multiple seams mining, the seam with relatively low gas content (protective seam) is often extracted prior to mining its overlying and/or underlying seams of high gas content and low permeability to minimize the ... In multiple seams mining, the seam with relatively low gas content (protective seam) is often extracted prior to mining its overlying and/or underlying seams of high gas content and low permeability to minimize the risk of high gas emission and outbursts of coal and gas. A key to success with this mining sequence is to gain a detailed understanding of the movement and fracture evolution of the overlying and underlying strata after the protective seam in extracted. In Zhuji mine, the No. 11-2 seam is extracted as a protective seam with the pillarless mining method by retaining goal-side roadways prior to its overlying No. 13-1 seam. An investigation has been undertaken in the panel 1111 (1) of Zhuji mine to physically simulate the movement and fracture evolution of the overlying strata alter the No. 1 I-2 seam is extracted. In the physical simulation, the displacement, strain, and deformation and failure process of the model for simulation were acquired with various means such as grating displacement meter, strain gauges, and digital photography. The simulation result shows that: (1) Initial caving interval of the immediate roof was 21.6 m, the first weighting interval was 23.5-37.3 m with the average interval of 33.5 m, and the periodic weighting interval of the main roof was in a range of 8.2-20.55 m and averaged at 15.2 m. (2) The maximum height of the caving zone after the extraction of No. 11-2 seam was 8.0 m, which was 4 times of the seam mining height and the internal strata of the caving zone collapsed irregularly. The mining-induced fractures developed 8-30 m above the mined No. 11-2 seam, which was 7.525 times of the seam mining height, the fracture zone was about 65° upward from the seam open-off cut toward the goaf, the height of longitudinal joint growth was 4-20 times of the mining seam height, and the height of lateral joint growth was 20-25 times of the mining seam height. (3) The "arch-in-arch" mechanical structure of the internal goaf was bounded by an expansion angle of broken strata in the lateral direction of the retained goaf-side roadway. The spatial and temporal evolution regularities of over- burden's displacement field and stress field, dynamic development process and distribution of fracture field were analyzed. Based on the simulation results, it is recommended that several goaf drainage methods, i.e. gas drainage with buried pipes in goaf, surface goaf gas drainage, and cross-measure boreholes, should be implemented to ensure the safe mining of the panel 1111 (1). 展开更多
关键词 Low-permeability coal seam Pillarless stress-relief mining Overburden movement Fracture evolution Physical simulation
下载PDF
Numerical simulation on pressure-relief deformation characteristics of underlying coal-rock mass after upper protective layer excavation 被引量:1
4
作者 Jian LIU Jie ZHAO Ming-Song GAO 《Journal of Coal Science & Engineering(China)》 2013年第3期276-281,共6页
Based on the occurrence features of Group B coal-seams at a coal mine in the Huainan coal mining area, the elasto-plastic mechanical damage constitutive functions and numerical model for the protective layer excavatio... Based on the occurrence features of Group B coal-seams at a coal mine in the Huainan coal mining area, the elasto-plastic mechanical damage constitutive functions and numerical model for the protective layer excavation were established. With the UDEC2D computer program, after the upper protective layer was mined, the stress field change trends, crack development, and expansion deformation trends of underlying coal rock seams in the floor of the working face were simulated and analyzed. The simulation results show the stress changes in coal rock seams, the evolution process of pre-cracks during the process of upper protective layer mining, the caved zone and fractured zone of the underlying coal rock seams. At the same time, the results from the actual investigation and analysis of protected layer deformation match the simulation values, which verifies the validity and accuracy of numerical simulation results. The study results have an important guiding significance for gas management in low permeability and high gas coal seams with similar mining conditions. 展开更多
关键词 upper protective layer mining pressure-relief deformation underlying coal-rock mass fracture development
下载PDF
Limits to foundation displacement of an extra high voltage transmission tower in a mining subsidence area 被引量:10
5
作者 Shu Qianjin Yuan Guanglin +1 位作者 Guo Guangli Zhang Yunfeit 《International Journal of Mining Science and Technology》 2012年第1期13-18,共6页
Given the background of a transmission tower erected on a particular mining subsidence area,we used finite element modeling to analyze the anti-deformation performance of transmission towers under a number of differen... Given the background of a transmission tower erected on a particular mining subsidence area,we used finite element modeling to analyze the anti-deformation performance of transmission towers under a number of different load conditions,including horizontal foundation displacement,uneven vertical downward displacement,wind loads and icing conditions.The results show that the failure in stability of a single steel angle iron represents the limit of the tower given ground deformation.We calculated the corresponding limits of foundation displacements.The results indicate that compression displacement of the foundation is more dangerous than tension displacement.Under complex foundation displacement conditions,horizontal foundation displacement is a key factor leading to failure in the stability of towers.Under conditions of compression or tension displacement of the foundation,wind load becomes the key factor.Towers do not fail when foundation displacements are smaller than 1% (under tension) or 0.5% (under horizontal compression or single foundation subsidence) of the distance between two supports. 展开更多
关键词 Mining subsidence area Electricity transmission tower Foundation displacement limit Finite element analysis Limit state Stability failure
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部