An improved encapsulation method of a sensing element for a cement-based piezoelectric sensor used in civil engineering structure was developed and some tests were carried out for validating this method. The cement-ba...An improved encapsulation method of a sensing element for a cement-based piezoelectric sensor used in civil engineering structure was developed and some tests were carried out for validating this method. The cement-based piezoelectric sensor of this kind is mainly used in concrete structure due to its compatibility with concrete, and the encapsulation method of its sensing element is important to the effectiveness and accuracy of the transfer of the stress from concrete to the sensing element. The sensor′s measurement error of the previous encapsulation method, which was induced by the area of the encapsulation material and the inherent difference of Young′s modulus between cement and encapsulation material, was analyzed theoretically using parallel model. In the improved method, the error is minimized by decreasing the area of the encapsulation material and changing the configuration of the cement and piezoelectric material in the sensor. Two sensors made by the previous and improved methods were embedded in two prisms respectively and the prisms were compressed on Material Test System. Through the comparison of the measurement errors of the two sensors, the improved method was evaluated. The test results show that the improved encapsulation method is effective and feasible.展开更多
The power transformer is the most important equipment of the high voltage power grid, however, some traditional methods of online partial discharge monitoring have some limitations. Based on many advantages of the opt...The power transformer is the most important equipment of the high voltage power grid, however, some traditional methods of online partial discharge monitoring have some limitations. Based on many advantages of the optical fiber sensing technology, we have done some research on fiber optics Fabry-Perot (FP) sensing which can be useful for the transformer on online partial discharge monitoring. This research aimed at improving the reliability of power system safety monitoring. We have done some work as follows: designing a set for fiber optics FP sensor preparation, according to the fabrication procedure strictly making out the sensors, building a reasonable signal demodulation system for fiber optics FP sensing, doing a preliminary analysis about online partial discharge signal monitoring, including the research on different discharge intensities with the same measuring distance and different measuring distances with the same discharge intensity, and then making a detailed analysis of the experimental results.展开更多
基金Supported by Hong Kong Research Grant Council to HKUSTunder grant HKUST6212/O2ENational Science Fund forDistinguished Young Scholars of China(No.50425824).
文摘An improved encapsulation method of a sensing element for a cement-based piezoelectric sensor used in civil engineering structure was developed and some tests were carried out for validating this method. The cement-based piezoelectric sensor of this kind is mainly used in concrete structure due to its compatibility with concrete, and the encapsulation method of its sensing element is important to the effectiveness and accuracy of the transfer of the stress from concrete to the sensing element. The sensor′s measurement error of the previous encapsulation method, which was induced by the area of the encapsulation material and the inherent difference of Young′s modulus between cement and encapsulation material, was analyzed theoretically using parallel model. In the improved method, the error is minimized by decreasing the area of the encapsulation material and changing the configuration of the cement and piezoelectric material in the sensor. Two sensors made by the previous and improved methods were embedded in two prisms respectively and the prisms were compressed on Material Test System. Through the comparison of the measurement errors of the two sensors, the improved method was evaluated. The test results show that the improved encapsulation method is effective and feasible.
基金This work was supported by the National Natural Science Foundation of China (Grant No. 51275373) and the Key Project of National Natural Science Foundation of China (Grant No. 50830230).
文摘The power transformer is the most important equipment of the high voltage power grid, however, some traditional methods of online partial discharge monitoring have some limitations. Based on many advantages of the optical fiber sensing technology, we have done some research on fiber optics Fabry-Perot (FP) sensing which can be useful for the transformer on online partial discharge monitoring. This research aimed at improving the reliability of power system safety monitoring. We have done some work as follows: designing a set for fiber optics FP sensor preparation, according to the fabrication procedure strictly making out the sensors, building a reasonable signal demodulation system for fiber optics FP sensing, doing a preliminary analysis about online partial discharge signal monitoring, including the research on different discharge intensities with the same measuring distance and different measuring distances with the same discharge intensity, and then making a detailed analysis of the experimental results.