Adaptive truss structures are a new kind of structures with integrated active members,whose dynamic characteristies can be beneficially modified to meet mission requirements.Active members containing actuating and sen...Adaptive truss structures are a new kind of structures with integrated active members,whose dynamic characteristies can be beneficially modified to meet mission requirements.Active members containing actuating and sensing units are the major components of adaptive truss structures.Modeling of adaptive truss structures is a key step to analyze the structural dynamic characteristics.A new experimental modal analysis approach,in which active members are used as excitatiDn sources for modal test,has been proposed in this paper.The excitation forces generated by the active members, which are different from the excitation forces exerted on structures in the conventional modal test,are internal forces for the truss structures.The relation between internal excitation forces and external forces is revealed such that the traditional identification method can be adopted to obtain modal parameters of adaptive structures.Placement problem of the active member in adaptive truss structures is also discussed in this work. Modal test and analysis are conducted with a planar adaptive truss structure by using piezoelectric active members in order to verify the feasibility and effectiveness of the proposed method.展开更多
To reduce output voltage noise and improve dynamic response performance,this study designed a buck converter on the basis of secondary filters and adaptive voltage positioning(AVP).A hybrid control method was proposed...To reduce output voltage noise and improve dynamic response performance,this study designed a buck converter on the basis of secondary filters and adaptive voltage positioning(AVP).A hybrid control method was proposed for the compensation of the secondary filter.The introduction of a high-frequency feedback path,in addition to the traditional feedback path,effectively improved the influence of the secondary filter on the loop stability and direct current regulation performance.A small-signal model of the buck converter based on the proposed control method was derived,and the stability and selection of control parameters were analyzed.AVP is realized using an easy-to-implement and low-cost control method that was proposed to improve dynamic response performance by changing the low-frequency gain of the control loop and load regulation of the output voltage.The experimental results of the buck converter showed that the proposed method effectively reduced the output voltage noise by 50%and improved the dynamic response capability to meet the target requirements of mainstream electronic systems.展开更多
文摘Adaptive truss structures are a new kind of structures with integrated active members,whose dynamic characteristies can be beneficially modified to meet mission requirements.Active members containing actuating and sensing units are the major components of adaptive truss structures.Modeling of adaptive truss structures is a key step to analyze the structural dynamic characteristics.A new experimental modal analysis approach,in which active members are used as excitatiDn sources for modal test,has been proposed in this paper.The excitation forces generated by the active members, which are different from the excitation forces exerted on structures in the conventional modal test,are internal forces for the truss structures.The relation between internal excitation forces and external forces is revealed such that the traditional identification method can be adopted to obtain modal parameters of adaptive structures.Placement problem of the active member in adaptive truss structures is also discussed in this work. Modal test and analysis are conducted with a planar adaptive truss structure by using piezoelectric active members in order to verify the feasibility and effectiveness of the proposed method.
文摘To reduce output voltage noise and improve dynamic response performance,this study designed a buck converter on the basis of secondary filters and adaptive voltage positioning(AVP).A hybrid control method was proposed for the compensation of the secondary filter.The introduction of a high-frequency feedback path,in addition to the traditional feedback path,effectively improved the influence of the secondary filter on the loop stability and direct current regulation performance.A small-signal model of the buck converter based on the proposed control method was derived,and the stability and selection of control parameters were analyzed.AVP is realized using an easy-to-implement and low-cost control method that was proposed to improve dynamic response performance by changing the low-frequency gain of the control loop and load regulation of the output voltage.The experimental results of the buck converter showed that the proposed method effectively reduced the output voltage noise by 50%and improved the dynamic response capability to meet the target requirements of mainstream electronic systems.