In this paper the growing process of China power grid from formation of local power grids to nationwide interconnection is reviewed. The scale and structure of power grid construction in the near future, especially th...In this paper the growing process of China power grid from formation of local power grids to nationwide interconnection is reviewed. The scale and structure of power grid construction in the near future, especially the planning on sending power from west to east, North-South supplementation and nationwide interconnection are introduced. In addition, the technologies to be extended in future grid development are briefed, such as HVDC, FACTS and compact transmission line, etc.展开更多
A CMOS charge-pump circuit with adjustable current is presented.A bandgap voltage reference,a low drop-out regulator,and a capacitive DC-DC voltage-booster are used to generate supply voltage for the current reference...A CMOS charge-pump circuit with adjustable current is presented.A bandgap voltage reference,a low drop-out regulator,and a capacitive DC-DC voltage-booster are used to generate supply voltage for the current reference.This generated voltage is insensitive to the changes of external power supply voltage and temperature,while the current reference itself is insensitive to temperature.The circuit is designed in 0.18μm 1.8V standard digital CMOS process.The simulated results show that the performance of the circuit is satisfied.展开更多
A DC regulated power supply with numerical control based on single chip microcomputer (SCM) is designed. SCM is the main controller and output voltage o{ DC power supply can be set by keyboard. The analog voltage ca...A DC regulated power supply with numerical control based on single chip microcomputer (SCM) is designed. SCM is the main controller and output voltage o{ DC power supply can be set by keyboard. The analog voltage can be obtained through D/A converter (DAC0832) so that different voltages can be provided by operational amplifier. The output voltage varies from 0 V to 12 V with the incremental value of 0. 1 V. The actual output voltage is shown in the nixietube. This DC regulated power supply is characterized by simple structure and easy operation.展开更多
The application areas of conventional push pull converters are limited because of high voltage stress of switches (twice of input voltage). This paper presents a novel zero voltage and zero current switching (ZCS)...The application areas of conventional push pull converters are limited because of high voltage stress of switches (twice of input voltage). This paper presents a novel zero voltage and zero current switching (ZCS) PWM push pull three level converter in which the voltage stress of switches is input voltage. With phase shifted modulation strategy, the leading switches can only realize zero voltage switching (ZVS), and the lagging switches can realize ZCS when block capacitor and block diodes are added. Using the strategy, the converter overcomes the drawbacks presented by the conventional push pull converter, such as magnetic aberration, large switch loss, and voltage spike on switches, so it can get higher efficiency, and a wider application area. The operating principle of the new converter is analyzed and verified on a 600 W, 50 kHz experimental prototype. Several zero voltage and zero current switching PWM push pull three level converters are proposed.展开更多
The design and implementation of a novel ADC architecture called ring-ADC for digital voltage regulator module controllers are presented. Based on the principle of voltage-controlled oscillators' transform from volta...The design and implementation of a novel ADC architecture called ring-ADC for digital voltage regulator module controllers are presented. Based on the principle of voltage-controlled oscillators' transform from voltage to frequency,the A/D conversion of ring-ADC achieves good linearity and precise calibration against process variations compared with the delay-line ADC. A differential pulse counting discriminator also helps decrease the power consumption of the ring-ADC. It is fabricated with a Chartered 0.35μm CMOS process, and the measurement results of the integral and differential nonlinearity performance are 0.92LSB and 1.2LSB respectively. The maximum gain error measured in ten sample chips is ± 3.85%. With sampling rate of 500kHz and when the voltage regulator module (VRM) works in steady state, the ring-ADC's average power consumption is 2.56mW. The ring-ADC is verified to meet the requirements for digital VRM controller application.展开更多
A low-voltage, low-power, and high-gain rail-to-rail operational amplifier (OpAmp) is presented. The replica-amplifier gain enhancement technique is applied to improve the DC gain of the amplifier, which does not de...A low-voltage, low-power, and high-gain rail-to-rail operational amplifier (OpAmp) is presented. The replica-amplifier gain enhancement technique is applied to improve the DC gain of the amplifier, which does not degrade the output swing and is very suitable for low-voltage applications. In a 0. 18/μm standard CMOS process,a 1V OpAmp with rail-to-rail output is designed. For a load capacitance of 5 pF,simulation by HSPICE shows that this OpAmp achieves an effective open-loop DC gain of 65. 9dB,gain bandwidth of 70.28 MHz,and phase margin of 50 with a quiescent power dissipation of 156.7μW.展开更多
The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Bas...The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Based on this,a fault locating system for HVDC transmission lines is developed.The system can support modern double ended and single ended travelling wave princi- ples simultaneously,and it is composed of three different parts:travelling wave data acquisition and processing system,communication network and PC based master station.In the system,the fault generated transients are induced from the ground leads of the over-voltage suppression capacitors of an HVDC line through specially developed travelling wave couplers.The system was applied to 500 kV Gezhouba-Nanqiao(Shanghai)HVDC transmission line in China.Some field operation experiences are summarized,showing that the system has very high reliability and accuracy,and the maximum location error is about 3 km(not more than 0.3%of the total line length). Obviously,the application of the system is successful,and the fault location problem has finally been solved completely since the line operation.展开更多
Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system...Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system stability will be affected by the performance of wind power plants,especially in the event of a fault.In this paper,the improvement of the dynamic stability in power system equipped by wind farm is examined through the supplementary controller design in the high voltage direct current(HVDC)based on voltage source converter(VSC)transmission system.In this regard,impacts of the VSC HVDC system and wind farm on the improvement of system stability are considered.Also,an algorithm based on controllability(observability)concept is proposed to select most appropriate and effective coupling between inputs-outputs(IO)signals of system in different work conditions.The selected coupling is used to apply damping controller signal.Finally,a fractional order PID controller(FO-PID)based on exchange market algorithm(EMA)is designed as damping controller.The analysis of the results shows that the wind farm does not directly contribute to the improvement of the dynamic stability of power system.However,it can increase the controllability of the oscillatory mode and improve the performance of the supplementary controller.展开更多
An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is w...An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance.展开更多
According to the structural characteristics of hazardous waste landfill, a new model based on the finite element method (FEM) is developed. The detection layer is considered as a sealed space and it is assumed that ...According to the structural characteristics of hazardous waste landfill, a new model based on the finite element method (FEM) is developed. The detection layer is considered as a sealed space and it is assumed that total current flows through the leak for the high resistivity of geomembrane liner. The leak current is regarded as a positive point current +I and the other current source is -I. Electrical potential of an arbitrary point in detection layer satisfies Poisson equation. Experiments for detecting leaks in liner were carried out. Excellent agreement between experimental data and simulated model data validates the new model. Parametric curves for a single leak show that with optimum selection of field survey parameters leaks can be detected effectively. For multiple leaks, the simulated results indicate that they are detectable when leak separation is larger than measurement spacing.展开更多
Heavy precipitation events occur often over the western Sichuan Basin in summer, near the transition zone between the Sichuan Basin and the steep terrain of the Tibetan Plateau. One such event -- a heavy precipitation...Heavy precipitation events occur often over the western Sichuan Basin in summer, near the transition zone between the Sichuan Basin and the steep terrain of the Tibetan Plateau. One such event -- a heavy precipitation process that occurred on 18-20 August 2010, with clear nocturnal peaks -- is chosen as a case to tentatively explore how the convection associated with convectivescale precipitation is initiated and propagated. By utilizing the vertical momentum equation from the viewpoint of separating perturbation pressure into dynamic and thermal parts, it is demonstrated that the vertical momentum is induced by the imbalance of several forces, including the dynamic/buoyant part of the perturbation pressure gradient force and the buoyancy force, with the latter dominating during the nocturnal-peak period. Although a negative value of the dynamic perturbation pressure gradient force partly offsets the positive buoyant forcing inside the strong updraft, the pattern of vertical motion tendency is largely attributable to its buoyancy because of its larger magnitude. Relative to the buoyancy component, the dynamic part of the vertical perturbation pressure gradient is also examined, revealing a smaller order of magnitude. Thus, it is the thermal effect that should be responsible for the initiation and propagation of convection. As for the convective-scale precipitation, it always presents a trailing morphology relative to the strong leading-side updraft. Furthermore, overlapping strong signals of vertical motion and its tendency point towards strong precipitation in the future.展开更多
According to the structural characteristics of hazardous waste landfill and the leakage current model of high voltage DC Landfill leakage detection, a sealed model is established detail. The detection layer of the haz...According to the structural characteristics of hazardous waste landfill and the leakage current model of high voltage DC Landfill leakage detection, a sealed model is established detail. The detection layer of the hazardous waste landfill is considered as a sealed assumed that the source current flows through the leak entirely. The leak is regard and analyzed in space and it is ed as a positive current resource + I located at the current entrance or a negative resource - I located at the current exit, which depends on the placement of the current supply. The electrical potential of an arbitrary in detection layer satisfies Poisson equation. The boundary condition is regarded as a natural bound- ary condition for the high resistivity of high density polyethylene (HDPE) membrane. Based on which a numerical calculation method is developed. Satisfactory agreement between experimental da- ta and simulated data validates the analysis. Parametric studies show that a larger horizontal distance between the power supply electrode and leak and a smaller distance between the detector electrodes and the detected liner are helpful to leak location. More parametric curves show that parameters leaks can be detected effectively with optimum selection of field survey.展开更多
For dealing with the resonance fault of ultra-high voltage transformers(UHVTs)with the parallel thyristor controlled reactor(TCR)+the filter compensator(FC)type static var compensator(SVC)caused by dc magnetic biasing...For dealing with the resonance fault of ultra-high voltage transformers(UHVTs)with the parallel thyristor controlled reactor(TCR)+the filter compensator(FC)type static var compensator(SVC)caused by dc magnetic biasing,a simulation model of UHVT with parallel SVC for the frequency analysis of the impedance characteristics and a magnetic-field coupling model for UHVT based on classic Jiles-Atherton hysteresis theories are constructed based on the MATLAB/Simulink platform.Both the theoretical and simulation results prove that the resonance fault is caused by the resonance point on the low-voltage side of the transformer,which will approach the 4th harmonic point under magnetic biasing.Based on the fault analysis,a new resonance control method is proposed by adding reactance with by-pass switches in series with FC branches.Under dc magnetic biasing,the cutoff of the by-pass switch will increase the series reactance rate of the FC branches and change the resonance point.In order to avoid the 7th harmonic increasement caused by this method,the firing angle of the TCR branches is locked between 130°and 180°.The effect of the proposed method is validated by the simulation model of a 750 kV UHVT and the results show that the mechanism analysis of the resonance fault is correct and the resonance control method is valid.展开更多
For converter transformer, AC-DC combined electric field can trigger space charge accumulation on oil-impregnated pressboard interface. The accumulation of space charge on oil-pressboard interface can result in electr...For converter transformer, AC-DC combined electric field can trigger space charge accumulation on oil-impregnated pressboard interface. The accumulation of space charge on oil-pressboard interface can result in electric field distortion, trend to trigger surface discharge of barriers. This paper studied the influence of surface charge on flashover voltage of oil-impregnated pressboard under AC-DC combined electric field. The study finds that the flashover voltage of oil-pressboard interface under negative polarity DC superimposed AC electric field is higher than that.of positive DC superimposed AC voltage to form composite electric field. It was found that homopolar surface charge has been accumulated on the interface of oil-pressboard with positive or negative DC voltage through measuring surface potential by the electrostatic capacitive probe. The surface charge produced electric field in the opposite direction, which weakening the synthetic electric field strength. What's more, under the same conditions, the negative surface charge density oil-pressboard is much larger than the positive.展开更多
文摘In this paper the growing process of China power grid from formation of local power grids to nationwide interconnection is reviewed. The scale and structure of power grid construction in the near future, especially the planning on sending power from west to east, North-South supplementation and nationwide interconnection are introduced. In addition, the technologies to be extended in future grid development are briefed, such as HVDC, FACTS and compact transmission line, etc.
文摘A CMOS charge-pump circuit with adjustable current is presented.A bandgap voltage reference,a low drop-out regulator,and a capacitive DC-DC voltage-booster are used to generate supply voltage for the current reference.This generated voltage is insensitive to the changes of external power supply voltage and temperature,while the current reference itself is insensitive to temperature.The circuit is designed in 0.18μm 1.8V standard digital CMOS process.The simulated results show that the performance of the circuit is satisfied.
文摘A DC regulated power supply with numerical control based on single chip microcomputer (SCM) is designed. SCM is the main controller and output voltage o{ DC power supply can be set by keyboard. The analog voltage can be obtained through D/A converter (DAC0832) so that different voltages can be provided by operational amplifier. The output voltage varies from 0 V to 12 V with the incremental value of 0. 1 V. The actual output voltage is shown in the nixietube. This DC regulated power supply is characterized by simple structure and easy operation.
文摘The application areas of conventional push pull converters are limited because of high voltage stress of switches (twice of input voltage). This paper presents a novel zero voltage and zero current switching (ZCS) PWM push pull three level converter in which the voltage stress of switches is input voltage. With phase shifted modulation strategy, the leading switches can only realize zero voltage switching (ZVS), and the lagging switches can realize ZCS when block capacitor and block diodes are added. Using the strategy, the converter overcomes the drawbacks presented by the conventional push pull converter, such as magnetic aberration, large switch loss, and voltage spike on switches, so it can get higher efficiency, and a wider application area. The operating principle of the new converter is analyzed and verified on a 600 W, 50 kHz experimental prototype. Several zero voltage and zero current switching PWM push pull three level converters are proposed.
文摘The design and implementation of a novel ADC architecture called ring-ADC for digital voltage regulator module controllers are presented. Based on the principle of voltage-controlled oscillators' transform from voltage to frequency,the A/D conversion of ring-ADC achieves good linearity and precise calibration against process variations compared with the delay-line ADC. A differential pulse counting discriminator also helps decrease the power consumption of the ring-ADC. It is fabricated with a Chartered 0.35μm CMOS process, and the measurement results of the integral and differential nonlinearity performance are 0.92LSB and 1.2LSB respectively. The maximum gain error measured in ten sample chips is ± 3.85%. With sampling rate of 500kHz and when the voltage regulator module (VRM) works in steady state, the ring-ADC's average power consumption is 2.56mW. The ring-ADC is verified to meet the requirements for digital VRM controller application.
文摘A low-voltage, low-power, and high-gain rail-to-rail operational amplifier (OpAmp) is presented. The replica-amplifier gain enhancement technique is applied to improve the DC gain of the amplifier, which does not degrade the output swing and is very suitable for low-voltage applications. In a 0. 18/μm standard CMOS process,a 1V OpAmp with rail-to-rail output is designed. For a load capacitance of 5 pF,simulation by HSPICE shows that this OpAmp achieves an effective open-loop DC gain of 65. 9dB,gain bandwidth of 70.28 MHz,and phase margin of 50 with a quiescent power dissipation of 156.7μW.
文摘The modern travelling wave based fault location principles for transmission lines are analyzed.In order to apply the travelling wave principles to HVDC transmission lines,the special technical problems are studied.Based on this,a fault locating system for HVDC transmission lines is developed.The system can support modern double ended and single ended travelling wave princi- ples simultaneously,and it is composed of three different parts:travelling wave data acquisition and processing system,communication network and PC based master station.In the system,the fault generated transients are induced from the ground leads of the over-voltage suppression capacitors of an HVDC line through specially developed travelling wave couplers.The system was applied to 500 kV Gezhouba-Nanqiao(Shanghai)HVDC transmission line in China.Some field operation experiences are summarized,showing that the system has very high reliability and accuracy,and the maximum location error is about 3 km(not more than 0.3%of the total line length). Obviously,the application of the system is successful,and the fault location problem has finally been solved completely since the line operation.
文摘Wind energy sources have different structures and functions from conventional power plants in the power system.These resources can affect the exchange of active and reactive power of the network.Therefore,power system stability will be affected by the performance of wind power plants,especially in the event of a fault.In this paper,the improvement of the dynamic stability in power system equipped by wind farm is examined through the supplementary controller design in the high voltage direct current(HVDC)based on voltage source converter(VSC)transmission system.In this regard,impacts of the VSC HVDC system and wind farm on the improvement of system stability are considered.Also,an algorithm based on controllability(observability)concept is proposed to select most appropriate and effective coupling between inputs-outputs(IO)signals of system in different work conditions.The selected coupling is used to apply damping controller signal.Finally,a fractional order PID controller(FO-PID)based on exchange market algorithm(EMA)is designed as damping controller.The analysis of the results shows that the wind farm does not directly contribute to the improvement of the dynamic stability of power system.However,it can increase the controllability of the oscillatory mode and improve the performance of the supplementary controller.
文摘An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance.
基金Project supported by the National High-Technology Research and Development Program of China(Grant No.2001AA644010)
文摘According to the structural characteristics of hazardous waste landfill, a new model based on the finite element method (FEM) is developed. The detection layer is considered as a sealed space and it is assumed that total current flows through the leak for the high resistivity of geomembrane liner. The leak current is regarded as a positive point current +I and the other current source is -I. Electrical potential of an arbitrary point in detection layer satisfies Poisson equation. Experiments for detecting leaks in liner were carried out. Excellent agreement between experimental data and simulated model data validates the new model. Parametric curves for a single leak show that with optimum selection of field survey parameters leaks can be detected effectively. For multiple leaks, the simulated results indicate that they are detectable when leak separation is larger than measurement spacing.
基金supported by the National Department Public Benefit Research Foundation[grant number GYHY201406003]the Open Research Fund Program of the Plateau Atmosphere and Environment Key Laboratory of Sichuan Province[grant number PAEKL-2015-K3]+2 种基金the National Natural Science Foundation of China[grant numbers 413750544157506441375052]
文摘Heavy precipitation events occur often over the western Sichuan Basin in summer, near the transition zone between the Sichuan Basin and the steep terrain of the Tibetan Plateau. One such event -- a heavy precipitation process that occurred on 18-20 August 2010, with clear nocturnal peaks -- is chosen as a case to tentatively explore how the convection associated with convectivescale precipitation is initiated and propagated. By utilizing the vertical momentum equation from the viewpoint of separating perturbation pressure into dynamic and thermal parts, it is demonstrated that the vertical momentum is induced by the imbalance of several forces, including the dynamic/buoyant part of the perturbation pressure gradient force and the buoyancy force, with the latter dominating during the nocturnal-peak period. Although a negative value of the dynamic perturbation pressure gradient force partly offsets the positive buoyant forcing inside the strong updraft, the pattern of vertical motion tendency is largely attributable to its buoyancy because of its larger magnitude. Relative to the buoyancy component, the dynamic part of the vertical perturbation pressure gradient is also examined, revealing a smaller order of magnitude. Thus, it is the thermal effect that should be responsible for the initiation and propagation of convection. As for the convective-scale precipitation, it always presents a trailing morphology relative to the strong leading-side updraft. Furthermore, overlapping strong signals of vertical motion and its tendency point towards strong precipitation in the future.
基金Supported by the National Basic Research Development Program of China(No.2010CB428506)the National High Technology Research and Development Program(No.2007AA061303)Beijing Higher Education Young Elite Teacher Project(YETP1756)
文摘According to the structural characteristics of hazardous waste landfill and the leakage current model of high voltage DC Landfill leakage detection, a sealed model is established detail. The detection layer of the hazardous waste landfill is considered as a sealed assumed that the source current flows through the leak entirely. The leak is regard and analyzed in space and it is ed as a positive current resource + I located at the current entrance or a negative resource - I located at the current exit, which depends on the placement of the current supply. The electrical potential of an arbitrary in detection layer satisfies Poisson equation. The boundary condition is regarded as a natural bound- ary condition for the high resistivity of high density polyethylene (HDPE) membrane. Based on which a numerical calculation method is developed. Satisfactory agreement between experimental da- ta and simulated data validates the analysis. Parametric studies show that a larger horizontal distance between the power supply electrode and leak and a smaller distance between the detector electrodes and the detected liner are helpful to leak location. More parametric curves show that parameters leaks can be detected effectively with optimum selection of field survey.
基金The Science Foundation of State Grid Xinjiang(No.SGTYHT/19-JS-215)。
文摘For dealing with the resonance fault of ultra-high voltage transformers(UHVTs)with the parallel thyristor controlled reactor(TCR)+the filter compensator(FC)type static var compensator(SVC)caused by dc magnetic biasing,a simulation model of UHVT with parallel SVC for the frequency analysis of the impedance characteristics and a magnetic-field coupling model for UHVT based on classic Jiles-Atherton hysteresis theories are constructed based on the MATLAB/Simulink platform.Both the theoretical and simulation results prove that the resonance fault is caused by the resonance point on the low-voltage side of the transformer,which will approach the 4th harmonic point under magnetic biasing.Based on the fault analysis,a new resonance control method is proposed by adding reactance with by-pass switches in series with FC branches.Under dc magnetic biasing,the cutoff of the by-pass switch will increase the series reactance rate of the FC branches and change the resonance point.In order to avoid the 7th harmonic increasement caused by this method,the firing angle of the TCR branches is locked between 130°and 180°.The effect of the proposed method is validated by the simulation model of a 750 kV UHVT and the results show that the mechanism analysis of the resonance fault is correct and the resonance control method is valid.
文摘For converter transformer, AC-DC combined electric field can trigger space charge accumulation on oil-impregnated pressboard interface. The accumulation of space charge on oil-pressboard interface can result in electric field distortion, trend to trigger surface discharge of barriers. This paper studied the influence of surface charge on flashover voltage of oil-impregnated pressboard under AC-DC combined electric field. The study finds that the flashover voltage of oil-pressboard interface under negative polarity DC superimposed AC electric field is higher than that.of positive DC superimposed AC voltage to form composite electric field. It was found that homopolar surface charge has been accumulated on the interface of oil-pressboard with positive or negative DC voltage through measuring surface potential by the electrostatic capacitive probe. The surface charge produced electric field in the opposite direction, which weakening the synthetic electric field strength. What's more, under the same conditions, the negative surface charge density oil-pressboard is much larger than the positive.