期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
基于NaI(TI)晶体的海水核辐射原位探测器可行性研究 被引量:5
1
作者 郑旻辉 潘建明 +1 位作者 杨俊毅 刘俊峰 《核电子学与探测技术》 CAS CSCD 北大核心 2013年第2期183-187,共5页
研制了一种基于NaI(TI)晶体的海水核辐射原位探测器,并进行了系列性能测试工作以及环境影响因素研究。研究结果显示:虽然探测器检测精度不及传统实验室方法,但其现有性能已可以满足海水核辐射现场预警监测需要;试验结果表明,为最大限度... 研制了一种基于NaI(TI)晶体的海水核辐射原位探测器,并进行了系列性能测试工作以及环境影响因素研究。研究结果显示:虽然探测器检测精度不及传统实验室方法,但其现有性能已可以满足海水核辐射现场预警监测需要;试验结果表明,为最大限度消除环境本底辐射值的干扰,探测器工作时应至少位于水下3 m且不能离底过近;经实验室验证,海水中钾元素确实会影响137Cs的测定,但该影响可由γ能谱中获取的40K数据进行校正。上述结果表明,利用基于NaI(TI)晶体的原位探测器技术现场实时监测海水核辐射是可行的,但仍需在探测器低功耗设计、探测效率提高以及试验场所构建等方面开展深入研究。 展开更多
关键词 海水核辐射 原位探测器 NaI(TI)晶体
下载PDF
Application of Mythen detector:In-situ XRD study on the thermal expansion behavior of metal indium 被引量:1
2
作者 Rong Du ZhongJun Chen +3 位作者 Quan Cai JianLong Fu Yu Gong ZhongHua Wu 《Science China(Physics,Mechanics & Astronomy)》 SCIE EI CAS CSCD 2016年第7期62-69,共8页
A Mythen detector has been equipped at the beamline 4B9A of Beijing Synchrotron Radiation Facility (BSRF), which is expected to enable BSRF to perform time-resolved measurement of X-ray diffraction (XRD) full-prof... A Mythen detector has been equipped at the beamline 4B9A of Beijing Synchrotron Radiation Facility (BSRF), which is expected to enable BSRF to perform time-resolved measurement of X-ray diffraction (XRD) full-profiles. In this paper, the thermal expansion behavior of metal indium has been studied by using the in-situ XRD technique with the Mythen detector. The indium was heated from 303 to 433 K with a heating rate of 2 K/rain. The in-situ XRD full-profiles were collected with a rate of one profile per 10 seconds. Rietveld refinement was used to extract the structural parameters. The results demonstrate that these collected quasi-real-time XRD profiles can be well used for structural analysis. The metal indium was found to have a nonlinear thermal expansion behavior from room temperature to the melting point (429.65 K). The a-axis of the tetragonal unit cell expands with a biquadratic dependency on temperature, while the c-axis contracts with a cubic dependency on temperature. By the time-resolved XRD measurements, it was observed that the [200] preferred orientation can maintain to about 403.15 K. While (110) is the last and detectable crystal plane just before melting of the polycrystalline indium foil. This study is not only beneficial to the application of metal indium, but also exhibits the capacity of in-situ time-resolved XRD measurements at the X-ray diffraction station of BSRF. 展开更多
关键词 Mythen detector thermal expansion Rietveld refinement XRD indium foil
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部